Fixed (TRM pin open), adjustable by external resistor
-20% / +10%
-15% / +15% -20% / +10%
-20% / +5% -15% / +15%
1.6%
t
Works over 105% of rating, low voltage protection (shut down) function is built-in.
117% - 127%
125% - 135% 117% - 127%
125% - 135%
Provided
Provided (Negative logic L : ON, H : OFF)
INPUT
OUTPUT
5
20
10max
10max
25max
100max
150max
100max
20max
6
17
10max
10max
25max
100max
150max
100max
20max
-20% / +10%
117% - 127%
CE/CQ-2
CES
GENERAL SPECIFICATIONS
ISOLATION INPUT-OUTPUT
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
ENVIRONMENT
VIBRATION
IMPACT
AGENCY APPROVALS
SAFETY
CASE SIZE/WEIGHT
OTHERS
COOLING METHOD
*1
*2
*3
*4
DC1,500V or AC1,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (20
t
15
C
)
-40 to +85
C
, 20 - 95%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
-40 to +100
C
, 20 - 95%RH (Non condensing), 9,000m (30,000feet) max (Option S:Refer to the instruction Manual)
10 - 55Hz, 49.0m/s
2
(5G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s
2
(20G), 11ms, once each along X, Y and Z axis
UL60950-1, C-UL (CSA60950-1), EN60950-1
57.9
X
8.5
X
22.76mm [2.28
X
0.33
X
0.9 inches] (W
X
H
X
D) / 26g max
Convection / Forced air
At rated input(DC24V,DC48V) and rated load and 25C, 2m/s.
Ripple and ripple noise is measured by using measuring board with ceramic capacitor 22mF. Refer to the Instruction Manual.
Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.
Refer to the instruction manual for input voltage derating.
External view
1. DIP
Model
57.9
[2.28]
50.8
7.62
+VIN
+VOUT
+S
TRM
-S
-VOUT
[0.3]
[2]
15.24
22.76
15.24
¶
Tolerance:
±
0.5 [
±
0.02]
¶
Weight:26g max
¶
Dimensions in mm, [ ]= inches
[0.6]
[0.6]
RC
-VIN
[0.9]
3.68
±
0.25
[0.14]
8.5max
[0.33]
6-º1.5
¶
±
VIN/RC/TRM/±S Pin
3.68
±
0.25
[0.14]
3.68
±
0.25
3.81
[0.15]
7.62
[0.3]
¶
Dimensions in mm,
[ ]= inches
¶
Div.:0.5inch
7.62
[0.3]
¶
±
VOUT Pin
[0.14]
[0.06]
¶
Recommended size for processing PCB
(TOP VIEW)
50.8
[2.0]
2-º2
[0.08]
º1.7
[0.07]
º2.2
[0.09]
º1
±
0.1
[0.04]
º1.5
±
0.1
[0.06]
2. SMD(optionS)
Model
24.5
[0.96]
57.9
[2.28]
50.8
[2]
Adsorption point
9
[0.35]
15.24
22.76
20.0
15.24
+VIN
[0.79]
[0.6]
-VIN
8.5max
[0.33]
[0.9]
RC
+VOUT
+S
TRM
-S
-VOUT
Coplanarity within 0.15
[0.01]
6-º2.9
[0.11]
¶
Recommended size for processing PCB
(TOP VIEW)
50.8
[2.0]
2-º3.4
[0.13]
[0.6]
º1.9
±
0.1
[0.07]
º2.4
-0.1
[0.09]
+0
¶
Dimensions in mm,
[ ]= inches
¶
Div.:0.5inch
15.24
[0.6]
¶
±
VIN/RC/TRM/±S Pin
¶
±
VOUT Pin
3.81
[0.15]
7.62
[0.3]
15.24
[0.6]
CE/CQ-3
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
便携式医疗设备的特殊性决定了它们应该是对用户友好的、必须工作在无菌环境下,并且空间占用小、耗能低。 同时,便携式医疗设备还需要足够的计算能力以便处理医疗数据,能够连接到无线或有线接口以便记录和发送数据。从设计人员的角度考虑,上述需求需要低功耗的单片机(MCU)和数字信号控制器(Digital Signal Controller,DSC)。 正是有了嵌入式处理器,设计人员才有可能设...[详细]