Ha-VIS24 HPR enlarged
Han
®
LOCFIELD
New thinking – design your RFID reading field
Ha-VIS LOCFIELD
®
Traveling wave RFID antenna
Identification
Part number
®
Idea
Ha-VIS LOCFIELD
2 m (active length), total length
2,5 m, diameter 3 mm, SMA (m),
EU
2 m (active length), total length
3 m, low loss coax, diameter 5
mm, SMA (m), EU
1 m (active length), total length
1,5 m, diameter 3 mm, SMA (m),
EU
0,3 m (active length), total length
0.6 m, diameter 3 mm, SMA (m),
EU
2 m (active length), total length
3 m, low loss coax, diameter 5
mm, SMA (m), FCC
1 m (active length), total length
1,5 m, diameter 3 mm, SMA (m),
FCC
0,3 m (active length), total length
0.6 m, diameter 3 mm, SMA (m),
FCC
2093 610 110010
2093 610 210010
The Ha-VIS LOCFIELD changes everything. Instead
of installing patch antennas, the coax antenna cable
itself becomes the antenna. The read range can be
varied from a few centimeters to about 2 m just by
changing the power of the RFID reader. The
®
LOCFIELD antenna can easily be installed in any
shape which serves the project in the best possible
way.
Applications:
-
Tool identification in machines
Door and window pass-throughs
Wireless sensor networks
Smart shelf
®
2093 610 110020
2093 610 110030
-
-
2093 610 220010
-
2093 610 120020
2093 610 120030
All data represent the current state of development at the time of print and are therefore non-binding.
HARTING reserves the right to modify designs without prior notice.
Ha-VIS LOCFIELD
®
Technical characteristics
General characteristics
Read range
Optimized for
from a few cm up to 2 m
(strongly depending on reader, configured power and tags)
Identification of tools in machines
Door openings and pass throughs
Wireless sensor networks
Smart shelf / smart work bench
Electric properties
Frequency range
Impedance
VSWR
Polarisation
Gain
Opening angle / read angle
Max. power
Connection
EU: 865 ... 868 MHz; FCC: 902 …928 MHz
50 Ohm
< 1.8:1
Linear (tags are read in any orientation)
approx. -7 dBi
360°
2 W (applied to antenna)
SMA male
TNC-rev (on request)
Mechanical properties
Length
Degree of protection
Installation
Operating temperature range
Storage temperature range
see first page
IP 65
Can be mounted directly on any non-conducting surface. On conducting
surfaces a distance of at least 2 cm is recommended
–20 ° ... +65 °C
C
–40 ° ... +85 °C
C
HARTING Software Development GmbH & Co. KG
Marienwerder Str. 2 | D-32339 Espelkamp | P.O.Box 14 73 | D-32328 Espelkamp
Phone: +49 5772 47-0 | auto-ID@HARTING.com | www.HARTING-RFID.com