Bus system cable - NBC-1500,0-937 - 1408862
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Bus system cable, PROFINET, 4-pos., RADOX GKW S, RAL 9005 (black), shielded, cable ring: 1500 m,
®
Key Commercial Data
Packing unit
GTIN
GTIN
Custom tariff number
Note
4046356839266
85444995
Made to Order (non-returnable)
1 STK
Technical data
Dimensions
Length of cable
1500 m
General data
Number of positions
4
Standards and Regulations
Concentration of fumes
Resistance to oil
Flame resistance
Other resistance
BS 6853 D.8.7
According to EN 61034-2, IEC 61034-2
acc. to EN 50306-3 section 4.8
According to DIN 60332-1-2
According to DIN EN 50266-2-5
Resistance to fuels EN 50306-3 Section 4.9/1.5 kV/1 minute
Resistance to acids and alkalis EN 50306-3 Section 4.10/1.5 kV/1
minute
Cable
Cable type
Cable type (abbreviation)
Signal type/category
Cable structure
Conductor cross section
AWG signal line
Conductor structure signal line
PROFINET railway applications
937
PROFINET CAT5 (IEC 11801), 100 Mbps
1x4xAWG22/7; SF/TQ
4x 0.34 mm²
22
7x 0.25 mm
11/13/2016 Page 1 / 3
https://www.phoenixcontact.com/hq/products/1408862
Bus system cable - NBC-1500,0-937 - 1408862
Technical data
Cable
Core diameter including insulation
Wire colors
Overall twist
Shielding
External sheath, color
Outer sheath thickness
External cable diameter D
Minimum bending radius, fixed installation
Cable weight
Outer sheath, material
Material conductor insulation
Conductor material
Conductor resistance
Working capacitance
Wave impedance
Signal speed
Shield attenuation
Coupling resistance
Nominal voltage, cable
Test voltage, cable
Fire protection in rail vehicles
approx. 1.5 mm
white-blue, orange-yellow
Star quad
Plastic-coated aluminum foil, tinned copper braided shield
black RAL 9005
approx. 1 mm
6.6 mm ±0.4 mm
6xD
70 kg/km
PE-X
Foamed PE
silver-plated Cu litz wires
≤ 54.4 Ω/km
≤ 65 pF (core-core)
≤ 100 pF (core-shield)
100 Ω ±5 Ω (f = 100 MHz)
75 c
40 dB (30 MHz ≤ f ≤ 100 MHz)
200.00 mΩ/m (f ≤ 30 MHz)
300 V AC
2000 V AC (50 Hz, 5 minutes)
BS 6853 (Category Ia, Ib, II)
GM/RT 2130 (Category Ia, Ib, II)
EN 45545 (Risk level HL1 - HL3)
DIN 5510 (Fire protection level 1, 2, 3, 4)
NF F16-101 (Category A1, A2, B)
NF F16-101 (Class C/F0)
NFPA 130
UNI CEI 11170 (Risk level LR1 - LR4)
Flame resistance
EN 60332-1-2
EN 50266
EN 60332-3-25
NF C32-070, 2.1
NF C32-070, 2.2
UL 1685, 12 (FT4)
in accordance with ISO 6722-1 5.22 (UN ECE-R 118.01)
Halogen-free
Resistance to oil
Other resistance
Concentration of fumes
According to EN 50267-2-1
according to IRM 902, 72 h at 100 °C
Resistance to fuels according to IRM 903, 168 h at 70 °C
BS 6853 D.8.7
11/13/2016 Page 2 / 3
https://www.phoenixcontact.com/hq/products/1408862
Bus system cable - NBC-1500,0-937 - 1408862
Technical data
Cable
EN 61034-2
UL 1685, 12 (FT4)
Fume corrosiveness
Fume toxicity
Ambient temperature (operation)
Ambient temperature (installation)
EN 50267-2-2
BS 6853 B.1
EN 50305, 9.2
-50 °C ... 90 °C (cable, fixed installation)
-40 °C ... 90 °C (cable, flexible installation)
-25 °C ... 90 °C
Drawings
Cable cross section
PROFINET railway applications [937]
Phoenix Contact 2016 © - all rights reserved
http://www.phoenixcontact.com
11/13/2016 Page 3 / 3