https://www.phoenixcontact.com/hq/products/1403420
Bus system cable - VS-M12MS-M12MS-93E-LI/8,0 - 1403420
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Bus system cable, Ethernet CAT5 (100 Mbps), 4-position, PUR halogen-free, water blue RAL 5021, shielded,
Plug straight M12, D-coded, on Plug straight M12, D-coded, Cable length: 8 m
Key Commercial Data
Packing unit
Minimum order quantity
GTIN
GTIN
Custom tariff number
Note
4046356651561
85444290
Made to Order (non-returnable)
1 STK
50 STK
Technical data
Dimensions
Length of cable
8m
Ambient conditions
Ambient temperature (operation)
Degree of protection
-25 °C ... 90 °C (Plug / socket)
IP65
IP67
IP68
General
Rated current at 40°C
Rated voltage
Number of positions
Insulation resistance
Coding
Signal type/category
Status display
4A
60 V
4
≥ 100 MΩ
D - data
Ethernet CAT5, 100 Mbps
No
11/13/2016 Page 1 / 3
https://www.phoenixcontact.com/hq/products/1403420
Bus system cable - VS-M12MS-M12MS-93E-LI/8,0 - 1403420
Technical data
General
Overvoltage category
Degree of pollution
Insertion/withdrawal cycles
II
3
≥ 100
Material
Flammability rating according to UL 94
Contact material
Contact surface material
Contact carrier material
Material of grip body
Material, knurls
V0
CuSn
Ni/Au
PA 66
TPU, hardly inflammable, self-extinguishing
Zinc die-cast, nickel-plated
Standards and Regulations
Flammability rating according to UL 94
V0
Cable
Cable type
Cable type (abbreviation)
Cable structure
Conductor cross section
AWG signal line
Conductor structure signal line
Core diameter including insulation
Wire colors
Twisted pairs
Overall twist
Shielding
Optical shield covering
External sheath, color
External cable diameter
Smallest bending radius, fixed installation
Smallest bending radius, movable installation
Outer sheath, material
Conductor material
Insulation resistance
Conductor resistance
Transmission characteristics (category)
Working capacitance
Wave impedance
Nominal voltage, cable
Test voltage Core/Core
Test voltage Core/Shield
Ethernet
93E
2x2xAWG26/7; SF/UTP
0.14 mm²
26
7x 0.16 mm
1 mm
white/orange-orange, white/green-green
2 cores to the pair
Two pairs with two fillers to the core
Plastic-coated aluminum foil, tinned copper braided shield
85 %
water blue RAL 5021
5.90 mm
30 mm (cable, fixed installation)
78 mm (cable, flexible installation)
PUR
Bare Cu litz wires
≥ 5 GΩ*km
≤ 284 Ω/km
CAT5 (IEC 11801:2002)
48 nF (At 800 Hz)
100 Ω ±15 % (at 1 ... 100 MHz)
125 V
1000 V
500 V
11/13/2016 Page 2 / 3
https://www.phoenixcontact.com/hq/products/1403420
Bus system cable - VS-M12MS-M12MS-93E-LI/8,0 - 1403420
Drawings
Schematic diagram
Schematic diagram
Pin assignment M12 male connector, 4-pos., D-coded, male side
Pin assignment M12 male connector, 4-pos., D-coded, male side
Cable cross section
Dimensional drawing
47,3
Ø14,8
M12
Ethernet [93E]
Plug, M12 x 1, straight, shielded
Dimensional drawing
M12
47,3
1
3
Circuit diagram
M12
1
3
2
4
Ø14,8
M12
Ø12
2
4
Plug, M12 x 1, straight, shielded
Contact assignment of M12 connector/socket
Phoenix Contact 2016 © - all rights reserved
http://www.phoenixcontact.com
Ø12