ELPAC FWC100 SERIES
CLASS I
100 Watt
ITE Desktop Power Supply
•
•
•
•
•
•
•
ITE Approval - EN60950
High Efficiency: Level VI
LED Indicator
Hold-up Time >20ms at full load
Grounded Output
5-Year Limited Warranty
Lifetime Expectation >5 years
Model Number
FWC100012A-12A
FWC100015A-12A
FWC100018A-11A
FWC100024A-11A
FWC100048A-11A
Output Voltage
12.0V
15.0V
18.0V
24.0V
48.0V
Output Current
8.3A
6.6A
5.5A
4.1A
2.0A
Peak Current
1
Total Regulation
2
10.0A
8.0A
6.7A
5.0A
2.5A
±5%
±5%
±5%
±5%
±5%
Typical Efficiency
3
89%
90%
90%
90%
91%
Notes
1) Maximum peak load (120W) lasting 500ms with a maximum 10% duty cycle.
2) Includes initial setting, line regulation, load regulation, and thermal drift.
3) Typical at 115VAC (including output cable).
INPUT
Input Voltage
Input Frequency
Input Current
Inrush Current
Power Factor
Zero Load
Power Consumption
Earth Leakage Current
(Typical)
85
– 264VAC
100 – 240VAC Nominal
47 – 63Hz
<2A rms
<60A at 230VAC cold start
>0.97
<0.2W
<150μA @ 132VAC @ 60Hz
<240μA @ 264VAC @ 60Hz
OUTPUT
Output Voltage
Total Regulation
Minimum Load
Start-Up Delay
Hold-Up Time
Ripple & Noise
Over Voltage Protection
Over Temperature
Protection
Over Current Protection
Short Circuit Protection
See Table
+/-5%
No minimum load required
<1.5s
>20ms at any input voltage
<1% pk-pk **
110 – 135%
Active - Recoverable; plus
Passive
- Non Recoverable
120 – 180%
Shutdown, auto-restart (hiccup mode)
Notes
**Ripple and noise measured with 20MHz bandwidth; 10μF tantalum capacitor in parallel with a 0.1μF ceramic capacitor.
Inventus Power
1200 Internationale Parkway
Woodridge, IL 60517, USA
Inventus Power Technical Support:
powersupplies@inventuspower.com
ELPAC FWC100 SERIES
100 Watt
Medical Desktop Power Supply
General
Efficiency
MTBF
Size
Weight
Avg. Efficiency 90.8% @
115VAC; 92.8% @ 230VAC
min. 200,000 hours
demonstrated
7.09” (180.2mm) x 2.27”
(57.5mm) x 1.52” (38.7mm)
1.55 lbs (0.70 Kg)
3
Environmental
Operating
Temperature
Storage
Temperature
Relative
Humidity
Cooling
Vibration
0 – 60°C (Full load to 40°C,
derate linearly to 50% load at
60°C)
-40°C to +85°C
5-95%, non-condensing
Natural Convection
All units production tested to
19.6m/s
2
EMC & Safety
Emissions
Immunity
FCC class B, CISPR2.2 class B
EN61000-3-2, -3
EN61000-4-2, -3, -4, -5, -6, -8,
-11
cTUVus
Certified by
TUV to the
following:
UL 60950-1
CAN/CSA-22.2 No.60950-1
CB per IEC60950-1
CE marked to LVD& EMC
Power Density 4.2W/in
Input Configuration
Standard
Input Cable
Not Provided
Output Pin Assignments
12V, 18 V
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Pin 6
Pin 7
Pin 8
+V1
+V1
Return
+V1
Return
+V1
Return
Return
Output Pin Assignments
18-48V
Pin 1
Return
Connection on
Power Supply IEC 320 C14 Receptacle
Body
Pin 2
Return
Output Configuration
Standard
Output Cable
Cord Size
4ft for 12V & 15V
6ft for 18V, 24V & 48V
4x16awg (12V& 15V); 4x18awg
(18V - 48V)
Switchcraft DIN-8 (12-15V)
P/N 15BL8MX (male pins)
Switchcraft DIN-5 (18-48V)
P/N 05BL5MX (male pins)
Pin 3
+V1
Pin 4
Return
Connector
(PSU side)
Pin 5
+V1
Mechanical Drawing
Inventus Power
1200 Internationale Parkway
Woodridge, IL 60517, USA
IP_DS_FWC100-I_072916_01
inventuspower.com
©2016 Inventus Power
,
All rights reserved.