1. At full load, 25°C, nominal input, 20 MHz bandwidth oscilloscope, output parallel with 0.1 μF and 10 μF capacitors to ground.
2. CoC Tier 2 complaint
PART NUMBER KEY
SMI10
-
5 -
X
-
I38
-
CXX
Base Number
Output Voltage
Blades:
V = North America, Europe, United Kingdom,
Australia, and China blade included
N = North America blade included
E = Europe blade included
B = United Kingdom blade included
A = Australia blade included
C = China blade included
K = No blades included
USB Type A Inlet
Reserved for Custom
Configurations
cui.com
For more information, please visit the
product page
|
For information on related products, view
Dc Power Connectors
CUI Inc
│
SERIES:
SMI10-USB
│
DESCRIPTION:
AC-DC POWER SUPPLY
date
09/15/2016
│
page
2 of 4
INPUT
parameter
voltage
frequency
current
leakage current
no load power consumption
at nominal input voltage
at nominal input voltage & frequency
at 115/230 Vac, 60/50 Hz
Level VI
CoC Tier 2
conditions/description
min
90
47
typ
max
264
63
0.3
0.25
0.075
0.075
units
Vac
Hz
A
mA
W
W
OUTPUT
parameter
load regulation
start-up time
hold-up time
at nominal input voltage, full load
5
conditions/description
min
typ
±5
3
max
units
%
s
ms
PROTECTIONS
parameter
over voltage protection
over current protection
short circuit protection
conditions/description
with zener clamp
output shut down, auto recovery
min
typ
max
10
4
units
Vdc
A
SAFETY & COMPLIANCE
parameter
isolation voltage
safety approvals
EMI/EMC
MTBF
RoHS
conditions/description
input to output at 10 mA for 1 minute
UL/cUL, GS, RCM, CCC, PSE
FCC Part 15B Class B, CE
as per Telcordia SR-332 Issue 2, at 115/230 Vac,
full load, 0 ~ 40°C
2011/65/EU
50,000
hours
min
typ
3,000
4,242
max
units
Vac
Vdc
ENVIRONMENTAL
parameter
operating temperature
storage temperature
conditions/description
min
0
-20
typ
max
40
60
units
°C
°C
cui.com
For more information, please visit the
product page
|
For information on related products, view
Dc Power Connectors
CUI Inc
│
SERIES:
SMI10-USB
│
DESCRIPTION:
AC-DC POWER SUPPLY
date
09/15/2016
│
page
3 of 4
MECHANICAL
parameter
dimensions
inlet plug
weight
conditions/description
60.9 x 38 x 29.2
interchangeable blades (North America, Europe, UK, Australia, China)
without interchangeable blades
40
g
min
typ
max
units
mm
MECHANICAL DRAWING
units: mm
PIN
1
2
3
4
Output Voltage
+5V
Short
Short
GND
+5
GND
1
4
INTERCHANGEABLE BLADES
BLADE
DESIGNATOR
REGION
BLADE
ACCESSORY
N
North
America
SMI-US-3L
E
Europe
SMI-EU-3L
B
UK
SMI-UK-3L
A
Australia
SMI-AU-3L
C
China
SMI-CN-3L
BLADE
cui.com
For more information, please visit the
product page
|
For information on related products, view
Dc Power Connectors
CUI Inc
│
SERIES:
SMI10-USB
│
DESCRIPTION:
AC-DC POWER SUPPLY
date
09/15/2016
│
page
4 of 4
REVISION HISTORY
rev.
1.0
1.01
description
initial release
updated datasheet
date
04/25/2016
09/15/2016
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
techsupport@cui.com
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
CUI offers a one (1) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.