1000V UL Flex Motor VFD, (3) 1/0 AWG (7x19x21) TC+Grd,
XLPE/PVC, Foil Shld, TC-ER
Product Description
Three 1/0 AWG stranded (7x19x21) tinned copper circuit conductors plus three symmetrical ground wires, cross-linked polyethylene insulation, two spiral
copper tape shields (100% Coverage), PVC jacket.
Technical Specifications
Product Overview
Suitable Applications:
Physical Characteristics (Overall)
Conductor
Element AWG Stranding
1/0
Ground Wire 4
7x19x21
7x19x25
AC Motor drives, VFD, Variable Frequency drives
Material
BC - Bare Copper
No. of Conductors
1
TC - Tinned Copper 3
Total Number of Conductors:
Insulation
Material
Nominal Wall Thickness
3
XLP - Cross Linked Polyolefin 0.057 in
Color Chart
Number
1
2
3
Color
Black and Numbered 1
Black and Numbered 2
Black and Numbered 3
Outer Shield Material
Type Description Layer Material
Tape
Tape
.002"
.002"
1
2
Coverage [%]
Spiral Copper 100 %
Spiral Copper 100 %
Outer Jacket Material
Material
Nominal Diameter Nominal Wall Thickness
0.083 in
PVC - Polyvinyl Chloride 1.292 in
Electrical Characteristics
Capacitance
Nom. Capacitance Conductor to
Conductor
45 pF/ft
Nom. Capacitance Conductor to Other Conductor to Shield
81 pF/ft
Construction and Dimensions
Stranding
Lay Length
Y mm
Conductor DCR
Nominal Conductor DCR
0.1 Ohm/1000ft
Current
Max. Recommended Current [A]
170 Amps per conductor @ 30°C
Inductance
Nominal Inductance
0.143 µH/ft
Voltage
Description
UL Voltage Rating
600 V RMS (NEC Type TC)
Voltage Rating [V]
CSA AWM I/II A/B 1000 V RMS (Flexible Motor Supply Cable) 1000 V RMS
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without
notice, and the listing of such information and specifications does not ensure product availability.
Belden provides the information and specifications herein on an "ASIS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages
(including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be incompliance with EU RoHS(Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be instock at Belden facilities and in our Distributor's
inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden's knowledge,
information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the safe handling, storage, and any other operation of the product
itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for
determining the applicability of legislation and regulations based on their individual usage of the product.
Belden declares this product to be incompliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC.
“tensymetry”这个词在《韦伯斯特词典》中没有解释,但在医学界却广为人知。由Tensys Medical Systems公司开发的tensymetry是一种使用生物机械、电气、软件工程的专有组合技术。利用这三种强大的技术,你可在手术室内对病人的心跳血压进行精确、连续、实时和非侵入性测量。 该技术结出的果实就是该公司的T-line Tensymeter产品。该产品线的最新进展是去年...[详细]