https://www.phoenixcontact.com/hq/products/2920308
Type 2 surge protection plug - VAL-MS 385/65 ST - 2920308
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Type 2 surge protection plug with varistor for VAL-MS 385/65/..., thermal monitoring, visual fault warning.
Key Commercial Data
Packing unit
Minimum order quantity
GTIN
GTIN
Custom tariff number
Note
4046356157346
85363030
Made to Order (non-returnable)
10 STK
10 STK
Technical data
Dimensions
Height
Width
Depth
Horizontal pitch
47 mm
17.7 mm
67.3 mm
1 Div.
Ambient conditions
Degree of protection
Ambient temperature (operation)
Ambient temperature (storage/transport)
Altitude
Permissible humidity (operation)
Shock (operation)
Vibration (operation)
IP20
-40 °C ... 80 °C
-40 °C ... 80 °C
≤ 2000 m (amsl (above mean sea level))
5 % ... 95 %
30g
7.5g
General
IEC test classification
II
11/15/2016 Page 1 / 3
https://www.phoenixcontact.com/hq/products/2920308
Type 2 surge protection plug - VAL-MS 385/65 ST - 2920308
Technical data
General
T2
EN type
IEC power supply system
Number of ports
SPD design
Mode of protection
Mounting type
Color
Housing material
Degree of pollution
Flammability rating according to UL 94
Design
Surge protection fault message
T2
TN
TT
One
Voltage-limiting type
L-N
L-PEN
On base element
black
PA 6.6
PBT
2
V-0
Male
optical
Protective circuit
Nominal voltage U
N
Nominal frequency f
N
Maximum continuous voltage U
C
Residual current I
PE
Standby power consumption P
C
Nominal discharge current I
n
(8/20) µs
Maximum discharge current I
max
(8/20) µs
Impulse discharge current (10/350)½µs, charge
Impulse discharge current (10/350)½µs, specific energy
Impulse discharge current (10/350)½µs, peak value l
imp
Short-circuit current rating I
SCCR
Voltage protection level U
p
Residual voltage U
res
240/415 V AC (TN)
240/415 V AC (TT)
50 Hz (60 Hz)
385 V AC
≤ 600 µA
≤ 230 mVA
30 kA
65 kA
1.25 As
1.56 kJ/Ω
2.5 kA
25 kA
≤ 1.8 kV
≤ 1.8 kV (at I
n
)
≤ 1.3 kV (at 10 kA)
≤ 1.2 kV (at 5 kA)
≤ 1.15 kV (at 3 kA)
TOV behavior at U
T
Response time t
A
Max. backup fuse with branch wiring
480 V AC (5 s / withstand mode)
≤ 25 ns
250 A AC (gG)
Standards and Regulations
Standards/regulations
IEC 61643-11 2011
11/15/2016 Page 2 / 3
https://www.phoenixcontact.com/hq/products/2920308
Type 2 surge protection plug - VAL-MS 385/65 ST - 2920308
Technical data
Standards and Regulations
EN 61643-11 2012
Drawings
Dimensional drawing
47,2
17,5
Circuit diagram
Approvals
Approvals
Approvals
KEMA-KEUR / CCA / IECEE CB Scheme / GL / EAC
Ex Approvals
Approval details
KEMA-KEUR
63,9
55,3
http://www.dekra-certification.com 2171147.01
CCA NTR-AT 1955
IECEE CB Scheme
http://www.iecee.org/ AT 3003
GL http://www.gl-group.com/newbuilding/approvals/index.html 36810-11 HH
EAC 7500651.22.01.00243
Phoenix Contact 2016 © - all rights reserved
http://www.phoenixcontact.com