* Not CE certified for the EU"
TR10R SERIES
10W SWITCHING
ADAPTER
Features
* Universal Input: 90-264Vac
* Interchangeable AC Plugs
* EMI Meets EN55022 Class “B” and
CISPR/FCC Class B, Conducted
* Continuous Short Circuit Protection
Ordering information
TR10RXXX
Model No.
-
XX
DC Plug Type
X
XX
DC Cable Length and Type
A:
* Please see Page 213 for
Without
OVP
01: 720mm
Option
more detailed descriptions
02: 1200mm
03: 1800mm
11: 7200mm with Ferrite Core
12: 1200mm with Ferrite Core
13: 1800mm with Ferrite Core
* 20AWG / UL2468
OUTPUT
MODEL
VOLTAGE
MAX.
LOAD
MIN.
LOAD
RIPPLE &
NOISE
VOLTAGE
ACCURACY
LINE
REGULATION
LOAD
REGULATION
(%) EFF.
(Typ.)
TR10R033
TR10R050
TR10R060
TR10R075
TR10R090
TR10R120
TR10R136
TR10R150
TR10R180
TR10R240
3.3V
5V
6V
7.5V
9V
12V
13.6V
15V
18V
24V
1600mA
1600mA
1500mA
1200mA
1100mA
850mA
750mA
700mA
550mA
400mA
0A
0A
0A
0A
0A
0A
0A
0A
0A
0A
50mV
50mV
1%
1%
1%
1%
1%
1%
1%
1%
±3%
±2%
±2%
±2%
±2%
±2%
±2%
±2%
±2%
±2%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±4%
±4%
±3%
±3%
±2%
±2%
±2%
±2%
±2%
±2%
60%
65%
68%
68%
73%
73%
76%
75%
76%
76%
1
Specifications
INPUT SPECIFICATIONS:
Voltage …....………........…........................................... 90~264Vac
Frequency ………………………………………….……………..... 47 to 63Hz
Input Current ………………….……………..................................... 0.4A max.
Inrush Current ………………….………….................... 40A max. @240Vac
Conducted EMI …………………………….……………. CISPR/FCC Class B
Leakage Current …………………………………………….…… 0.25mA max.
TR10R Series Derating Curve
100%
Rated Load(%)
75%
50%
25%
0%
0
10
20
30
40
Ambient Temperature(
o
C)
50
60
20LFM(Natural Convection)
OUTPUT SPECIFICATIONS:
Holdup Time ……………………………………………… 10ms typ. @115Vac
Short Circuit Protection …………….…………… Continuous(Auto Recovery)
Over Current Protection ………………...................… Constant Current type
Temperature Coefficient ……………………..............................… ±0.05%/℃
NOTE:
1. Voltage setpoint at 60% full load
2. Add a 0.1uF ceramic capacitor and a 10uF E.L. capacitor to output for
Ripple & Noise measuring @20MHz BW.
3. Line regulation is measured from 100Vac to 240Vac with full load.
4. Load regulation is measured from 60% to full load and from 60% to
20% load (60% +/- 40% load)
GENERAL SPECIFICATIONS:
Isolation …………………………………………… Input to output = 4,242VDC
Operating Temperature ................................... 0 ~ 60℃(see derating curve)
Storage Temperature ………………………………..........……........ -20~85℃
Humidity …………………...….........……….... 93% RH max. Non condensing
Cooling …………………………………………………….. Natural Convection
Switching Frequency ………………………………………….. 40KHz Typical
MTBF ……….… MIL-HDBK-217F, GB, 25℃/115VAC ……. 200K hrs min.
Altitude …………………………………………………………………… 2000m
Dimensions ……..…….. 2.835x1.811x1.378Inches (72.00x46.00x35.00mm)
Weight ……………………………………………………… 155g(0.34 Pounds)
SAFETY AND EMC:
Emission and lmmunity ……….… EN55022 Class B, FCC Part 15 Class B
EN61000-6-3, EN61000-3-2, EN61000-3-3
EN55024, EN61204-3, EN61000-6-1
Safety …………………………….…… IEC60950-1, EN60950-1, UL60950-1
Mechanical Specification
All Dimensions are in inches(mm)
Tolerance:Inches:X.XXX±0.02
Millimeters:X.XX±0.5
DC Plug type: V+ ─●)─ V-
DC Plug:Right Angle(ψ5.5/ψ2.5)L9.5mm
18AWG / 1800mm
+
-
Typical at 25˚C, nominal line and 75% load, unless otherwise Specified
2