INFRARED RECEIVER MODULE
Description
The MIM-0KM1AKL is miniaturized infrared receivers for
remote control and other appplications requiring improved
ambient light rejection.
The separate PIN diode and preamplifier IC are assembled
on a single leadframe.
The epoxy package contains a special IR filter.
This module has excellent performance even in disturbed
ambient light applications and provides protection against
uncontrolled output pulses.
MIM-0KM1AKL
Features
Photo detector and preamplifier in one package
Internal filter for PCM frequency
High immunity against ambient light
Improved shielding against electric field disturbance
2.4-Volt supply voltage; low power consumption
TTL and CMOS compatibility
MIM-0KM1xKL Series Models
MIM-0KM1AKL 37.9KHz
MIM-0KM1BKL 32.7KHz
MIM-0KM1CKL 40.0KHz
MIM-0KM1DKL 36.7KHz
MIM-0KM1FKL 56.7KHz
Unit : mm
BLOCK DIAGRAM
V
S
TRAP
BPF
TRIMMING
Output
ABLC
f
o
GND
Unity Opto Technology Co., Ltd.
1/12/01
MIM-0KM1AKL
Absolute Maximum Ratings
Item
Supply voltage
Operating temperature
Storage temperature
Soldering temperature
Symbol
V
CC
T
opr
T
stg
T
sd
Ratings
3.0 ~ 5.8
-10 ~ + 60
-20 ~ + 75
260
Unit
V
℃
℃
℃
Maximum 5 seconds
@ Ta=25℃
Remark
Electro-optical characteristics (Vcc=2.4V)
Parameter
Current consumption
Response wavelength
Tuning frequency
Output form
H level output voltage
L level output voltage
H level output pulse width
L level output pulse width
Distance between emitter & detector
Half angle
V
0
h
V
0
l
Twh
Twl
L
1(Vcc=3V)
L
2(Vcc=2.4V)
△Θ
400
400
10.0
7.0
±45
Symbol
Icc
λp
f
0
940
37.9
Min.
Typ.
Max.
5.0
Unit
mA
nm
KH
Z
(T
a
=25°C , Vcc=2.4V)
Remarks
Under no signal
- - - - - active low output - - - - -
2.2
0.5
800
800
V
V
μs
μs
m
m
deg
Horizonal direction
Note 1
Test Method
A. Standard Transmitter
25cm
ON/OFF pulse width satisfied from 25 cm to detection limit
600µs
Transmitter
Duty 50%
PD3516
+2.4V
10kΩ
10µF
V
out
GND
Oscilloscope
600µs
600µs
Fig 1. Burst Wave
Fig 2. Standard Transmitter Measurement circuit
B. Detection Length Test
θ
θ
D.U.T
L
θ:
indicates horizontal and vertical directions
Transmitter output
V
out
Unity Opto Technology Co., Ltd.
10k
1/12/01
MIM-0KM1AKL
C. Pulse Width Test
Transmitter output
600µs 600µs
DUT output pulse
Twl
Twh
V
0
h
V
0
l
Application Circuit
Vcc **)
MIM-0KM1xKL
MIE-544A2
3
102P
C
Decoder
1
2
GND
*) only necessary to supress power supply disturbances.
**) tolerated supply voltage range : 2.4V < Vcc < 5.8V
CHARACTERISTIC CURVES (T
A
=25℃)
℃
2.8
2.7
2.6
2.4
2.2
2.0
400
2
3
6
4
5
Supply Voltage Vcc (V)
7
8
0.1
1
10
Input Level (mV
p-p
)
100
1000
Output Pulse Width t
PW
(
µ
s)
Supply Current Icc (mA)
900
800
700
600
500
Input Level V
IN
(mV
P-P
)
Burst length * 600µs, cycle = 1.2ms
tpw: Average value of output from start
of signal input to 60th pulse
SUPPLY VOLTAGE vs. SUPPLY CURRENT
INPUT LEVEL vs.OUTPUT PULSE WIDTH
NOTE 1. Distance between emitter & detector specifies maximum distance that output wave form satisfies
the standard under the conditions below against the standerd transmitter.
(1)Measuring place ………Indoor without extreme reflection of light.
(2)Ambient light source… Detecting surface illumination shall be 200±50Lux under ordinary
hite fluorescense lamp of no high frequency lighting.
(3)Standard transmitter … Burst wave indicated in Fig 1. of standard transmitter
shall be arranged to 50mVp-p under the measuring circuit specified in Fig 2.
Unity Opto Technology Co., Ltd.
1/12/01
MIM-0KM1AKL
Reliability
Test item
High temparature
High temp. & high humi.
Low temparature
Heat cycle
Dropping
Ta=+60℃ Vcc=5.0 V
Ta=+40℃ 90%RH Vcc=5.0V
Ta= -10℃ Vcc=5.0V
-20℃(0.5H) ~ +75℃(0.5H) 20cycle
Test devices shall be dropped 3 times naturally
onto hard wooden board from a 75cm height position.
NOTE 2. (electro-optical charactistics) shall be satisfied sfter leaving 2 hours in the normal temperature .
NOTE 3. (electro-optical charactistics) shall be satisfied and no conoid deforms
and destructions of appearance .(excepting deforms of terminals)
Test condition
t=240H
t=240H
t=240H
Standard
Note 2.
Note 2.
Note 2.
Note 2.
Note 3.
Inspection standard
1.Among electrical characteristics , total number shall be inspected on items blow.
1-1 front distance between emitter & detector
1-2 Current consumption
1-3 H level output voltage
1-4 L level output voltage
2.Items except above mentioned are not inspected particularly , but shall fully satisfy
CAUTION ( When use and storage of this device )
1.Store and use where there is no force causing transformation or change in quality .
2.Store and use where there is no corrosive gas or sea(salt) breeze .
3.Store and use where there is no extreme humidity .
4.Solder the lead-pin within the condition of ratings. After soldering do not add extra force .
5.Do not wash this device . Wipe the stains of diode side with a soft cloth. You can
use the solvent , ethylalcohol or methylalcohol or isupropylene only .
6.To prevent static electricity damage to the Pre-AMP make sure that the human body
, the soldering iron is connected to ground before using .
7.Put decoupling device between Vcc and GND for reduse the noise from power supply line .
8.The performance of remote-control system depends on environments condition and ability
of periferal parts. Customer should evaluate the performance as total system in those conditions
after system up with components such as commander , micon and this receiver module .
Guarantee period and scope
1.Guarantee period
One year after delivery to desired place .
2.Guarantee scope
A re-delivery of goods will be carried out if the cause of malfunction lies in our
device .However no responsibilities be taken for the inconveniences caused by
the malfunction of our devices .
Others
1.This device is not design to endure radiative rays and heavily charged particles .
2.In case where any trouble or questions arise,both parties agress to make full discussion
covering the said problem .
Unity Opto Technology Co., Ltd.
1/12/01