HVR125 - HVR180
PRV : 2500 - 8000 Volts
Io : 0.2 - 0.5 Ampere
FEATURES :
*
*
*
*
*
*
High current capability
High surge current capability
High reliability
Low reverse current
Low forward voltage drop
Pb / RoHS Free
HIGH VOLTAGE
RECTIFIER DIODES
DO - 41
0.107 (2.7)
0.080 (2.0)
1.00 (25.4)
MIN.
0.205 (5.2)
0.166 (4.2)
MECHANICAL DATA :
* Case : DO-41 Molded plastic
* Epoxy : UL94V-O rate flame retardant
* Lead : Axial lead solderable per MIL-STD-202,
Method 208 guaranteed
* Polarity : Color band denotes cathode end
* Mounting position : Any
* Weight : 0.34 gram
0.034 (0.86)
0.028 (0.71)
1.00 (25.4)
MIN.
Dimensions in inches and ( millimeters )
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Rating at 25
°
C ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
RATING
Maximum Repetitive Peak Reverse Voltage
Maximum RMS Voltage
Maximum DC Blocking Voltage
Maximum Average Forward Current
Ta = 50°C
SYMBOL
V
RRM
V
RMS
V
DC
I
F(AV)
I
FSM
HVR
125
2500
1750
2500
HVR
130
3000
2100
3000
0.5
HVR
140
4000
2800
4000
HVR
150
5000
3500
5000
0.3
30
HVR
160
6000
4200
6000
HVR
170
7000
4900
7000
0.2
HVR
180
8000
5600
8000
UNIT
V
V
V
A
A
Maximum Peak Forward Surge Current
8.3ms Single half sine wave Superimposed
on rated load (JEDEC Method)
Maximum Peak Forward Voltage at I
F
= 1.0 A
Maximum DC Reverse Current
at Rated DC Blocking Voltage
Junction Temperature Range
Storage Temperature Range
Ta = 25°C
Ta = 100°C
V
F
I
R
I
R(H)
T
J
T
STG
3.3
5.0
5.0
50
- 40 to + 150
- 40 to + 150
8.0
V
µA
µA
°C
°C
Page 1 of 2
Rev. 03 : March 24, 2005
RATING AND CHARACTERISTIC CURVES ( HVR125 - HVR180 )
FIG.1 - DERATING CURVE FOR OUTPUT
RECTIFIED CURRENT
0.5
30
FIG.2 - MAXIMUM NON-REPETITIVE PEAK
FORWARD SURGE CURRENT
PEAK FORWARD SURGE
CURRENT, AMPERES
AVERAGE FORWARD OUTPUT
CURRENT, AMPERES
0.4
HVR125 - HVR130
HVR140 - HVR150
24
0.3
HVR160 - HVR180
18
0.2
12
0.1
6
0
0
25
50
75
100
125
150
175
0
1
2
4
6
10
20
40
60
100
AMBIENT TEMPERATURE, (
°
C)
NUMBER OF CYCLES AT 60Hz
FIG.3 - TYPICAL FORWARD CHARACTERISTICS
10
HVR125 - HVR130
FIG.4 - TYPICAL REVERSE CHARACTERISTICS
FORWARD CURRENT, AMPERES
10
T
J
= 100
°C
REVERSE CURRENT,
MICROAMPERES
1
HVR140 - HVR150
1.0
HVR160 - HVR180
0.1
Pulse Width = 300
µs
1% Duty Cycle
0.01
0
1.0
2.0
3.0
4.0
5.0
6.0
T
J
= 25
°C
7.0
8.0
9.0
10
0.1
T
J
= 25
°C
0.01
0
20
40
60
80
100
120
140
FORWARD VOLTAGE, VOLTS
PERCENT OF RATED REVERSE
VOLTAGE, (%)
Page 2 of 2
Rev. 03 : March 24, 2005