Page 1 of 3
LVOM-160 Series
Product Features:
•
•
•
•
•
•
•
•
•
•
•
Up to 160 W continuous power
Industry standard 2’’x 4’’ footprint
18 W/in3 power density
Universal input (85-264 Vac / 125 -373 Vdc)
3.3V to 48V outputs available
Active power correction factor (98%)
No minimum load required
Full medical and ITE safety approvals
Typical efficiency of 90%
OVP, OTP and short-cicuit protection
Compliant to worldwide safety and EMC standards
MODEL GUIDE
Model
LVOM-160-3
LVOM-160-5
LVOM-160-12
LVOM-160-15
LVOM-160-24
LVOM-160-48
V1
3.3V
5V
12V
15V
24V
48V
Without Air
Flow
14A
14A
8.3A
6A
4.16A
2.08A
With Air Flow
(400 LFM)
20A
20A
13.3A
8A
6.66A
3.33A
V1 PARD
(Pk-Pk)
50mV
50mV
120mV
50mV
240mV
480mV
V2
12V
12V
12V
12V
12V
12V
Without Air
Flow
0.5A
0.5A
0.5A
0.5A
0.5A
0.5A
With Air Flow
(400 LFM)
0.5A
0.5A
0.5A
0.5A
0.5A
0.5A
INPUT
Parameter
AC Input Voltage
DC Input Voltage
Input Frequency
Input Current
Inrush Current
Efficiency
Power Factor
Notes/Description
Min
90
170
47
Nom
115/230
50/60
Max
264
370
63
2.3
Units
VAC
VDC
Hz
A
%
90VAC
No damage at 230 VAC cold start
Full load
90VAC
90
0.98
OUTPUT
Parameter
Set-Point Accuracy
Adjustment Range
Line Reguation
Load Regulation
Notes/Description
Min
Nom
±1.0
±5.0
Max
Units
%
%
%
%
90-264 V ac
V1
V2
±0.1
±1
±5
LHV Power Corporation | 10221 Buena Vista Avenue | Santee, CA 92071, USA | Tel: 619 258 7700 | Fax: 619 258 7733 | sales@lhvpower.com
Page 2 of 3
LVOM-160 Series
Parameter
Cross Regulation
Transient Response
Ripple & Noise
Rise Time
Startup Time
Holdup Time
Minimum Load
Temperature Drift
Notes/Description
V1
V2
50% load change, recovery to regulation band within 1msec
Peak-peak 20MHz bandwith
Min
Nom
±1
±15
Max
Units
%
%
10
±1
0.2
1
5
16
0
±0.25
%
%
msec
sec
msec
A
mV/C
90 VAC, 160W load
PROTECTION
Parameter
Undervoltage Lockout
Over-Voltage Protection
Over-Current Protection
Short-Circuit Protection
Over -Temperature
Input Fuse
Isolation Input/Ouput
Isolation Input/Ground
Leakage Current
Notes/Description
No damage, auto-recovery
Latched shutdown
Auto-recovery
Auto-recovery
Auto-recovery
Line and neutral
For 1 minute
For 1 minute
115/230 VAC
Min
60
Nom
75
±15
Max
130
150
Units
VAC
%
%
5656
5656
16
110/200
VDC
VAC
uA
SAFETY & COMPLIANCE
IEC 61000 Family
ESD
Radiated Field
EFT
Surge
Conducted RF Immunity
Magnetic Field Immunity
Dips & Interruptions
Standard
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-850
EN61000-4-11
Condition
15KV air discharge 8KV contact discharge
3V/m, 80-1000MHz, 80% AM, 3m distance
±2kV on AC power port±1kV on signal/control lines
±1KV line-to-line, ± 2 KV line to earth±0.5 kV for outdoor cables
3Vrms, 0.15-80Mhz, 80% AM
50 and 60 Hz, 3A/m
Dip to 40% for 5 cycles (100msec)
Dip to 70% for 25 cycles (500msec)
Dropout to 5% for 10 msec
Interrupts > 95% for 5 sec
Criteria
A
A
A
A
A
A
B
B
B
C
Voltage Fluctuation
EN61000-3-3
Emissions
Conducted EMI
Radiated EMI
Harmonic currents
Standard
EN55022
EN55022
EN61000-3-2
VDE, UL, c-UL
Condition
Class B
ClassA
Criteria
4dB margin
4dB margin
Safety Agency Approvals
Agencies