336.9K hrs min. Telcordia SR-332 (Bellcore) ; 109.1K hrs min.
250*127*41mm (L*W*H)
1.64Kg; 6pcs/10.8Kg/1.1CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25
℃
of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltages. Please check the derating curve for more details.
5. There is high possibility to trigger the floating over voltage protection when PV voltage is trimmed from a high voltage level to a lower voltage level at light
load or no load condition. It is suggested that turn off the power supply and set PV voltage to the lowest level, then adjust output voltage to a desired value.
6. Strongly recommended that external output capacitance should not exceed 5000uF. (Only for: RSP-750-5)
7. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on
a 720mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to
perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com)
8. The ambient temperature derating of 3.5
℃
/1000m with fanless models and of 5
℃
/1000m with fan models for operating altitude higher than 2000m(6500ft).
File Name:RSP-750-SPEC 2018-10-30
750W Single Output Power Supply
Block Diagram
RSP-750
+S
series
PFC fosc : 90KHz
PWM fosc : 70KHz
I/P
EMI
FILTER
ACTIVE
INRUSH
CURRENT
LIMITING
RECTIFIERS
&
PFC
POWER
SWITCHING
O.L.P.
RECTIFIERS
&
FILTER
+V
-V
-S
PFC
CONTROL
PWM
CONTROL
DETECTION
CIRCUIT
O.V.P.
RECTIFIERS
CONTROL
ON/OFF
DC OK
PV/PC
REMOTE ON-OFF
AUX POWER(12V/0.1A)
AUX GND
AUX
POWER
FAN
RECTIFIERS
&
FILTER
Static Characteristics
100
90
INPUT
MODEL
5V
500W
100A
450W
90A
24V
751.2W
31.3A
676.08W
28.17A
12V
750W
62.5A
675W
56.25A
27V
750.6W
27.8A
675.54W
25.02A
15V
750W
50A
675W
45A
48V
753.6W
15.7A
678.24W
14.13A
100~264VAC
80
70
90VAC
MODEL
LOAD (%)
60
50
40
INPUT
100~264VAC
90
95
100
115
264
90VAC
INPUT VOLTAGE (VAC) 60Hz
Derating Curve
Efficiency vs Load (48V Model)
95
100
90
80
EFFICIENCY (%)
85
80
75
70
230V
60
LOAD (%)
50
40
20
-30
0
10
20
30
40
50
60
70
(HORIZONTAL)
AMBIENT TEMPERATURE (
℃
)
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD
※
The curve above is measured at 230VAC.
File Name:RSP-750-SPEC 2018-10-30
750W Single Output Power Supply
Function Manual
1.Remote Sense
The remote sensing compensates voltage drop on the load wiring up to 0.5V.
RSP-750
series
1
+S
3
-S
-VS
4
5
PV
PS
6
7
CN50
13
CN50
TB1
PC DC_OK GND
REMOTE
ON-OFF
PO
8
GND G-AUX 12V-AUX
14
1
13
+VS
2
PIN3
-S
-V
LOAD
-
+
+V
PIN1 +S
2
14
Fig 1.1
◎
The
+S
signal should be connected to the positive terminal of the load whereas
-S
signal to the negative terminal.
◎
By factory default, on CN50
, Remote ON-OFF
(pin13) and
12V-AUX
(pin14),
PV
(pin5) and
PS
(pin6), and
PC
(pin7) and
PO
(pin8, respectively, are
shorted when shipped. The power supply will have no output if the shorting connector is not assembled unless certain functin needs to be activated.
2.Remote ON-OFF
※
The power supply can be turned ON/OFF by using the “Remote ON-OFF” function.
CN50
1
3
+S
-S
-VS
4
6
5
PV
PS
8
7
13
REMOTE
PC DC_OK GND
ON-OFF
CN50
TB1
1
13
+VS
2
SW
PO
GND G-AUX 12V-AUX
14
-V
LOAD
-
+
+V
2
14
Fig 2.1
Between Remote
ON-OFF(pin13)
and
12V-AUX(pin14)
SW close (Short)
SW open (Open)
Power Supply Status
ON
OFF
◎
When multiple power supplies need to turn ON/OFF simultaneously by Remote ON-OFF control, -S & -V on CN50, as well as +S & +V, on each power
supply should be connected.
File Name:RSP-750-SPEC 2018-10-30
750W Single Output Power Supply
RSP-750
series
3. Output Voltage Programming (or, PV / remote voltage programming / remote adjust / margin programming / dynamic voltage trim)
※
In addition to the adjustment via the built-in potentiometer, the output voltage can be trimmed to 40~110% of the nominal voltage by applying
EXTERNAL VOLTAGE.
Vout 120%(Typ.)
Nominal Vout
120
110
100
80
60
40
20
Non-Linear
OUTPUT VOLTAGE (%)
External Voltage (2~5.5VDC)
1
+S
+VS
UVP 10%(Typ.)
3
-S
-VS
4
5
PV
PS
7
CN50
11
13
PC DC_OK GND
REMOTE
ON-OFF
PO
8
GND G-AUX 12V-AUX
14
2
1
2
3
4
5 5.5 6
EXTERNAL VOLTAGE (VDC)
◎
If EXTERNAL VOLTAGE (VDC) <0.5V,the power supply may
enter under voltage protection; it needs to be restarted to work.
Fig 3.1
※
Caution: By factory default, the Output Voltage Programming is not activated, and
PV (pin5)
and
PS(pin6)
are shorted by connector. Whenever this
function is not needed to activate, as assumed in other sections’ diagrams, please keep
PV (pin5)
and
PS(pin6)
shorted ; other wise, the
power supply will have no output.
4. Constant Current Level Programming (or, PC / remote current programming / dynamic current trim)
※
The constant current level can be trimmed to 40~110% of the rated current by applying EXTERNAL VOLTAGE.
Rated Current
Io 115%(Typ.)
CONSTANT CURRENT LEVEL (%)
120
110
100
80
60
40
20
Non-Linear
External Voltage (2~5.5VDC)
1
+S
+VS
2
3
-S
-VS
4
6
5
PV
PS
7
CN50
11
13
PC DC_OK GND
REMOTE
ON-OFF
PO
GND G-AUX 12V-AUX
14
1
2
3
4
5 5.5 6
EXTERNAL VOLTAGE (VDC)
Fig 4.1
※
Caution: By factory default, the Output Current Programming is not activated, and
PC(pin7)
and
PO(pin8)
are shorted by connector. Whenever this
function is not needed to activate, as assumed in other sections’ diagrams, please keep