D12 Series DIN Rail High Power Fiber
Optic
Sensor
Datasheet
Powerful Self-Contained Sensors for Use with Glass or
Plastic
Fiber
Optic
Assemblies
•
•
•
•
•
•
•
•
Fiber
optic
sensors for DIN rail
mounting;
cabled or quick disconnect (QD)
Fast response: 500
μs
standard, 50
μs
for Y & Y1 models
Visible red light source; models for use with either glass or
plastic fibers
Choice of either NPN (sinking) or PNP (sourcing) complementary outputs; 150 mA maximum
(continuous)
load
Normally closed output of most models may be wired as a
diagnostic
alarm output (depending
upon hookup to power)
Sensors operate from 10 V dc to 30 V dc
LED indicators for Power On and N.O. Output
Conducting
7-segment LED bargraph indicates received signal strength, output overload, and marginal excess
gain
WARNING: Not To Be Used for Personnel
Protection
Never use this device as a sensing device for personnel
protection.
Doing so could lead to serious injury or death.
This device
does not include the self-checking redundant circuitry necessary to allow its use in personnel safety
applications.
A sensor failure
or
malfunction
can cause either an energized or de-energized sensor output
condition.
CAUTION:
Electrostatic
Discharge (ESD)
ESD
Sensitive
Device.
Use proper handling procedures to prevent ESD damage to these devices. The module does not contain any
specific
ESD
protection
beyond the structures contained in its integrated circuits. Proper handling procedures should include
leaving devices in their
anti-static
packaging
until
ready for use; wearing
anit-static
wrist straps; and assembling units on a
grounded,
static-dissipative
surface.
Models
Glass Fiber
Optic
Sensors
Models
1
D12SN6FV(Q)
D12SN6FVY(Q)
D12SN6FVY1(Q)
D12SP6FV(Q)
D12SP6FVY(Q)
D12SP6FVY1(Q)
Output Type
NPN
NPN
NPN
PNP
PNP
PNP
Response Speed
Standard 500
μs
response
time
Selectable 50
μs
high speed response mode
Selectable 50
μs
high speed response mode and 20 ms pulse stretcher
Standard 500
μs
response
time
Selectable 50
μs
high speed response mode
Selectable 50
μs
high speed response mode and 20 ms pulse stretcher
See the performance curves
Range
Plastic
Fiber
Optic
Sensors
Models
1
D12SN6FP(Q)
D12SN6FPY(Q)
D12SN6FPY1(Q)
D12SP6FP(Q)
D12SP6FPY(Q)
D12SP6FPY1(Q)
Output Type
NPN
NPN
NPN
PNP
PNP
PNP
Response Speed
Standard 500
μs
response
time
Selectable 50
μs
high speed response mode
Selectable 50
μs
high speed response mode and 20 ms pulse stretcher
Standard 500
μs
response
time
Selectable 50
μs
high speed response mode
Selectable 50
μs
high speed response mode and 20 ms pulse stretcher
See the performance curves
Range
Overview
D12 sensors are compact, self-contained visible-red
fiber optic
sensors for DIN rail
mounting.
D12 sensors are designed for use with Banner glass and cut-
to-length
plastic fiber optics.
Standard D12FP and D12FV
plastic
and glass
fiber optic
sensors
offer
fast 0.5 millisecond (500
μs)
response. D12FVY Series
and D12FPY Series sensors have switch-selectable 50
μs/500 μs
response modes for
applications
that require a faster, high speed response
time.
D12FVY1 and D12FPY1 models have switch-selectable response
times
along with a built-in 20 ms pulse stretcher for use with loads (or input circuits) that
are too slow to react to quick sensing events when using the 50
μs
response mode.
1 Include "Q" in model
suffix
to specify 6-inch cable with 4-pin pico-style QD. Omit "Q" to specify models with 6-foot
attached
cable. Models with 30-foot
attached
cable are available.
Original Document
32822 Rev. G
11 September 2017
32822
D12 Series DIN Rail High Power Fiber
Optic
Sensor
All models operate from 10 V dc to 30 V dc. D12 sensors are available with a choice of NPN or PNP complementary outputs (one output normally open,
one output normally closed). The normally closed output of FP and FV models (only) may be used as a
diagnostic
alarm output, depending on the wiring
of the sensor to the power supply. All models are available with either an
attached
cable or a 6-inch cable with a pico-style quick disconnect connector.
Plastic fiber
models may be used with either the small diameter (0.254 mm and 0.508 mm/0.010 inch and 0.020 inch) or the large diameter (1.06 mm/
0.040 inch) Banner cut-to-length
plastic fibers.
LED Indicators
Two top-mounted LED indicators:
• Green = dc power on
• Amber = Normally Open Output
Conducting
Seven-Segment Moving-Dot LED Bargraph
On all D12 sensors
operating
in the 500
μs
(standard) response mode, a red seven-
segment moving-dot LED bargraph illuminates to indicate the
relative
strength of
the received light signal. This feature
simplifies
the
sensitivity
adjustment and
fiber
optic
alignment, and provides a constant reference over
time
for overall sensing
system performance.
In all models and in both response modes, segment #1 of the bargraph
flashes
to
indicate an output overload.
On all sensors
operating
in the 500
μs
response mode, segment #7
flashes
to
indicate marginal excess gain.
On standard (FP and FY) models, a
flashing
LED corresponds to the On state of the
D12's alarm output.
Note:
The seven segment bargraph and marginal
excess gain
indication
(segment #7) are
inoperative
in
the 50
μs
response mode on Y and Y1 models.
Sensivity Control
D12s have a 15-turn
sensitivity
control, with a
slotted
brass screw clutched at both
ends of travel.
Figure 1. Features
Installing Glass Fibers
1. Gently seat an o-ring onto each sensor end of the
fiber.
Sensor end, glass fiber
O-ring (supplied with fiber)
Groove
2. Slide the sensor ends into the
fiber
ports as far as they will go.
3. Push
firmly
on the
fiber
ends to compress the o-ring, and while holding the sensor ends snugly in place, slide the
fiber
retaining clip into the slot.
4. Press the retaining clip in
until
it snaps into the groove.
Installing
Plastic
Fibers
1. Cut the
fiber
ends according to the
instructions
included with the
fibers.
2. Slide the
fiber
gripper up (open).
3. If you are using 0.254 mm or 0.508 mm (0 .010 inch or 0.020 inch) diameter
fibers:
Insert the adaptor into the ports as far as it will go.
Fiber adapter
4. For all
fiber
diameters: Insert the prepared
plastic fiber
sensor ends gently into the ports as far as they will go.
5. Slide the
fiber
gripper back down to lock it.
2
www.bannerengineering.com - Tel: +1-763-544-3164
P/N 32822 Rev. G
D12 Series DIN Rail High Power Fiber
Optic
Sensor
Wiring Diagrams
NPN (Sinking) Standard Wiring
3
1
4
2
Load
Load
NPN (Sinking) Alarm Wiring
1
3
4
2
Load
Alarm
–
10-30V dc
+
–
10-30V dc
+
PNP (Sourcing) Standard Wiring
1
3
4
2
Load
Load
PNP (Sourcing) Alarm Wiring
3
1
4
2
Load
Alarm
+
10-30V dc
–
+
10-30V dc
–
Specifications
Sensing Range
See the excess gain curves;
Performance Curves—Glass Fiber
Optic
Sensors
on page 5
and
Performance
Curves—Plastic
Fiber
Optic
Sensors
on page 5
Sensing Beam
Visible red, 680 nm
Supply Voltage
10 V dc to 30 V dc at 45 mA maximum, exclusive of load
Protected against reverse polarity and
inductive
load transients
Output
Configurations
Solid-state dc complementary outputs; see the models table for details.
The normally closed (N.C.) output of standard FP and FV models may be used as an alarm
output, depending upon the hookup to the power supply.
Output
Rating
Complementary outputs, one normally open (N.O.) and the other normally closed (N.C.).
150 mA maximum each output. No false pulse on power-up. (False pulse
protection
circuit causes a 0.1 second delay on power-up.) Short-circuit protected.
Off-state
leakage current
<10 µA at 30 V dc
On-state
saturation
voltage
<1 V at 10 mA dc; <1.5 V at 150 mA dc
The
total load
may not exceed 150 mA
Response Time (FV, FP models)
500 µs on; 500 µs
off
Repeatability is 130 µs
Response Time (FVY, FVY1, FPY, and FPY1 models)
FVY, FVY1, FPY, and FPY1 models have switch-selectable standard 500 µs response mode
plus a high speed (50 µs
on/off)
mode. Repeatability in the high-speed (50
μs)
mode is 15
µs. FPY1 and FVY1 models (when used in the 50
μs
response mode) include a 20 ms pulse
stretcher for use in
applications
in which the load (or input circuit) requires a longer
input signal.
Response
time
and repeatability are independent of signal strength.
Adjustments
All models have a
sensitivity
control on top of the module (15-turn
slotted
brass screw,
clutched at both ends of travel). FVY and FPY (high speed models) also have a top-
mounted response mode selector switch.
Construction
Black ABS housing with transparent acrylic cover. The
fiber
clamping element is acetal.
Stainless steel M3 × 0.5 hardware for use with
mounting
bracket (supplied).
Connections
2 m
(6.5-ft)
or 9 m (30-foot)
attached
PVC-covered cable, or 6-inch cable with pico-type
4-pin QD connector
Mounting
Bracket
D12 Series sensors mount directly to a standard DIN rail, or may be through-hole
mounted using the supplied
mounting
bracket and M3 x 0,5 hardware
Bracket material is black PBT polyester
Environmental
Rating
NEMA 2; IEC IP11
Operating Conditions
Operating
Temperature:
−20
°C to +70 °C (−4 °F to +158 °F)
90% at +50 °C maximum
relative
humidity (non-condensing)
Application
Notes
D12 Series sensors are designed to deliver very high
optical
energy (excess gain). They
should not be used for
applications
which
offer
low
optical
contrast (that is, only a small
difference
in received light levels between the light and dark sensing
conditions).
Examples include
diffuse
mode sensing of objects in front of a
reflective
background and
opposed mode sensing of non-opaque materials.
D12 sensors excel in
applications
requiring high excess gain (for example, for long-range
sensing, sensing with long
fiber
lengths,
diffuse
sensing of materials with low
reflectivity,
etc.).
Required Overcurrent
Protection
WARNING:
Electrical
connections
must be made by
qualified
personnel in accordance with local and
national
electrical codes and
regulations.
Overcurrent
protection
is required to be provided by end product
application
per the
supplied table.
Overcurrent
protection
may be provided with external fusing or via Current
Limiting,
Class 2 Power Supply.
Supply wiring leads < 24 AWG shall not be spliced.
For
additional
product support, go to
http://www.bannerengineering.com.
Supply Wiring (AWG)
20
22
24
26
28
30
Required Overcurrent
Protection
(Amps)
5.0
3.0
2.0
1.0
0.8
0.5
Certifications
P/N 32822 Rev. G
www.bannerengineering.com - Tel: +1-763-544-3164
3
D12 Series DIN Rail High Power Fiber
Optic
Sensor
Dimensions and Features—Glass Fiber
Optic
Models
Fiber-retaining Clip
(Supplied with Sensor)
7-Segment Display
Response Mode Selector *
Output Indicator
35.5 mm
(1.40")
Power Indicator
Sensitivity Adjustment
30.0 mm
(1.18")
12.0 mm
(0.47")
64.4 mm
(2.52")
20.2 mm
(0.79")
Pull to Relase
Bracket
5.0 mm
(0.20")
* Response Mode Selection on FVY and FVY1 models only
Mounting Bracket
(Included)
Glass Fiber Emitter Port
Glass Fiber Receiver Port
Dimensions and
Features—Plastic
Fiber
Optic
Models
Fiber Gripper –
Slide up to install or
release fibers
Signal Strength and Diagnostics Indicators
Response Mode Selector *
Output indicator
35.5 mm
(1.40")
Power indicator
Sensitivity Adjustment
30.0 mm
(1.18")
12.0 mm
(0.47")
64.4 mm
(2.52")
20.2 mm
(0.79")
Mounting bracket
(included)
Pull to release
bracket
Plastic fiber emitter port
Plastic fiber receiver port
5.0 mm
(0.20")
* Response Mode Selection on FPY and FPY1 models only
Small fiber adapter
Dimensions—D12 Bracket
D12 Sensors mount directly to a standard 35 mm DIN rail, or may be through-hole mounted using the supplied
mounting
bracket and stainless steel M3 ×
0.5 hardware.
2.5 mm
(0.10")
Section A-A
A
2.3 mm
(0.09")
24.5 mm
(1.00")
15.2 mm
(0.60")
9.9 mm
(0.39")
4.8 mm
(0.19")
ø 3.25 mm (2)
(0.128")
A
0.94 mm
(0.037")
8.6 mm
(0.34")
11.9 mm
(0.47")
35.0 mm
(1.38")
ø 4.45 mm (2)
(0.175")
ø 7.9 mm x 3.0 mm
deep (2)
(0.31" x 0.12")
3.45 mm (2)
(0.136")
4
www.bannerengineering.com - Tel: +1-763-544-3164
P/N 32822 Rev. G
D12 Series DIN Rail High Power Fiber
Optic
Sensor
Performance Curves—Glass Fiber
Optic
Sensors
Diffuse
Mode
Opposed Mode
Performance
Curves—Plastic
Fiber
Optic
Sensors
Diffuse
Mode—0.020 Inch Fibers
Diffuse
Mode—0.040 Inch Fibers
Opposed Mode—0.020 Inch Fibers
Opposed Mode—0.040 Inch Fibers
Opposed Mode—0.040 Inch Fibers and Model
L2 Lenses for Extended Sensing Range
P/N 32822 Rev. G
www.bannerengineering.com - Tel: +1-763-544-3164
5