Number of digital outputs: 1; Number of analogue outputs: 1
[s]
[kHz]
[V]
[mA]
10...30 DC; ("supply class 2" to cULus)
55
III
yes
< 0.3
230
[mm]
[mm]
PNP
normally open / normally closed; (parameterisable + 1x current output)
150...1600; (Target: 200 x 200 mm)
IO-Link
threaded type
M18 x 1 / L = 97.5
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — UGT510-01 — 15.10.2020 —
UGT510
Ultrasonic sensor
UGA01600E1KG/IO-LINK/US
Outputs
Total number of outputs
Electrical design
Number of digital outputs
Output function
Max. voltage drop switching
output DC
Permanent current rating of
switching output DC
Switching frequency DC
Number of analogue outputs
Analogue current output
Max. load
Short-circuit protection
Overload protection
Resolution of analogue
output
Detection zone
Sensing range
Blind zone
Angle of aperture cylindrical
Max. deviation from the 90°
angle sensor/object
Accuracy / deviations
Temperature compensation
Hysteresis
Switch point drift
Linearity error of analogue
output
Notes on the accuracy /
deviation
Repeatability
Response times
Response time
Software / programming
Parameter setting options
hysteresis / window; second switch point; Switch-on and switch-
off delay; switch-on operations; Teach function; light-on/dark-on mode
[ms]
< 300; (analogue output)
[%]
[%]
[%]
yes
<2
-2...2
<2
The indicated values are reached after a warm-up time of min. 20 minutes
1%
[mm]
[mm]
[°]
[°]
150...1600; (Target: 200 x 200 mm)
150
15; (±2)
±4
[mA]
[Ω]
[V]
[mA]
[Hz]
2
PNP
1
normally open / normally closed; (parameterisable + 1x current output)
2.2
100
3
1
4...20
500
yes
yes
< 3 mm
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — UGT510-01 — 15.10.2020 —
Smart Sensor: Device Identification; Multi-channel, two setpoint switching sensor, type
0 Generic Profiled Sensor; Process Data Variable; Device Diagnosis; Teach Channel
yes
A
3.2
bit length
16
4
2
DeviceID
702
application specific tag; operating hours counter
For further information please see the IODD PDF file under "Downloads"
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — UGT510-01 — 15.10.2020 —
UGT510
Ultrasonic sensor
UGA01600E1KG/IO-LINK/US
Displays / operating elements
Display
Teach function
Accessories
Items supplied
Remarks
Remarks
Pack quantity
Electrical connection
Connector: 1 x M12
operating voltage "supply class 2" according to cULus
1 pcs.
lock nuts: 2, stainless steel
switching status
echo
yes
2 x LED, yellow
1 x LED, green
Connection
Pin 4 =
IO-Link
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — UGT510-01 — 15.10.2020 —
UGT510
Ultrasonic sensor
UGA01600E1KG/IO-LINK/US
Diagrams and graphs
1:
2:
3:
4:
5:
6:
distance
Detection zone
switch-on/switch-off graph
Target 200 x 200 mm
50% of the target in the detection zone
switch point
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — UGT510-01 — 15.10.2020 —