30NWK2CZ47
TOSHIBA Schottky Barrier Rectifier Stack Trench Schottky Barrier Type
30NWK2CZ47
Switching Mode Power Supply Application
Converter & Chopper Application
·
·
·
·
Repetitive peak reverse voltage: V
RRM
= 100 V
Peak Forward Voltage: V
FM
= 0.83 V (max)
Average output recified current: I
O
= 30 A
Low switching losses and output noise.
Unit: mm
Maximum Ratings
(Ta
=
25°C)
Characteristics
Repetitive peak reverse voltage
Average output recified current
Peak one cycle surge forward current
(non-repetitive, sine wave)
Junction temperature
Storage temperature range
Screw Torque
Symbol
V
RRM
I
O
I
FSM
T
j
T
stg
¾
Rating
100
30
250 (50 Hz)
-40~150
-40~150
0.6
Unit
V
A
A
°C
°C
N½m
JEDEC
JEITA
TOSHIBA
―
―
12-10C1A
Electrical Characteristics
(Ta
=
25°C)
Characteristics
Peak forward voltage
Repetitive peak reverse current
Junction capacitance
Thermal resistance
Symbol
V
FM
I
RRM
C
j
R
th (j-c)
Test Condition
I
FM
=
15 A
V
RRM
=
100 V
V
R
=
10 V, f
=
1.0 MHz
DC Total, Junction to case
Weight: 2.0 g (typ.)
Min
¾
¾
¾
¾
Typ.
¾
¾
250
¾
Max
0.83
50
¾
2.5
Unit
V
mA
pF
°C/W
Note: V
FM
, I
RRM
, C
j
: A value of one cell.
1
2001-11-14
30NWK2CZ47
Polarity
③
*1
①
②
*1
*2
*2
MARK
30NWK2C
TYPE
30NWK2CZ47
Marking
Lot Number
Month (starting from alphabet A)
Year (last number of the christian era)
Handling Precaution
Schottky barrier diodes are having large-reverse-current-leakage characteristic compare to other rectifier
products. This current leakage and not proper operating temperature or voltage may cause thermal runaway.
Please take forward and reverse loss into consideration when you design.
2
2001-11-14
30NWK2CZ47
i
F
– v
F
100
One cell
32
28
24
P
F (AV)
– I
O
(A)
Average forward power dissipation
P
F (AV)
(W)
180°
120°
90°
iF
Instantaneous forward current
Tj
=
150°C
10
100°C
75°C
20
16
12
8
4
0
0
a =
30°
60°
25°C
1
Rectangular waveform
(one cell)
0°
a
360°
Conduction angle
a
4
8
12
16
20
24
28
32
36
0.1
0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
Instantaneous forward voltage
vF
(V)
Average output rectified current
I
O
(A)
Tc max – I
O
160
140
120
100
80
60
40 0°
a
360°
20
0
0
Conduction
angle
a
VR
=
50 V
4
8
12
16
20
24
28
32
36
a =
30°
Rectangular
waveform
60°
90°
320
280
240
200
Surge forward current (non-repetitive)
Ta
=
25°C
One cell
Average forward power dissipation
Tc max (°C)
Surge forward current
180°
I
FSM
(A)
f
=
60 Hz
160
50 Hz
120
80
40
0
1
120°
3
5
10
30
50
100
Average output rectified current
I
O
(A)
Number of cycles
r
th (j-c)
– t
10
One cell
5
1000
C
j
– V
R
(typical)
f
=
1 MHz
(pF)
500
300
Ta
=
25°C
One cell
Transient thermal impedance
rth (j-c) (°C/W)
3
1
0.5
0.3
Junction capacitance
0.01
0.1
1
10
Cj
100
50
30
0.1
0.001
10
1
100
3
5
10
30
50
100
Time t (s)
Reverse voltage V
R
(V)
3
2001-11-14
30NWK2CZ47
RESTRICTIONS ON PRODUCT USE
000707EAA
·
TOSHIBA is continually working to improve the quality and reliability of its products. Nevertheless, semiconductor
devices in general can malfunction or fail due to their inherent electrical sensitivity and vulnerability to physical
stress. It is the responsibility of the buyer, when utilizing TOSHIBA products, to comply with the standards of
safety in making a safe design for the entire system, and to avoid situations in which a malfunction or failure of
such TOSHIBA products could cause loss of human life, bodily injury or damage to property.
In developing your designs, please ensure that TOSHIBA products are used within specified operating ranges as
set forth in the most recent TOSHIBA products specifications. Also, please keep in mind the precautions and
conditions set forth in the “Handling Guide for Semiconductor Devices,” or “TOSHIBA Semiconductor Reliability
Handbook” etc..
·
The TOSHIBA products listed in this document are intended for usage in general electronics applications
(computer, personal equipment, office equipment, measuring equipment, industrial robotics, domestic appliances,
etc.). These TOSHIBA products are neither intended nor warranted for usage in equipment that requires
extraordinarily high quality and/or reliability or a malfunction or failure of which may cause loss of human life or
bodily injury (“Unintended Usage”). Unintended Usage include atomic energy control instruments, airplane or
spaceship instruments, transportation instruments, traffic signal instruments, combustion control instruments,
medical instruments, all types of safety devices, etc.. Unintended Usage of TOSHIBA products listed in this
document shall be made at the customer’s own risk.
·
The information contained herein is presented only as a guide for the applications of our products. No
responsibility is assumed by TOSHIBA CORPORATION for any infringements of intellectual property or other
rights of the third parties which may result from its use. No license is granted by implication or otherwise under
any intellectual property or other rights of TOSHIBA CORPORATION or others.
·
The information contained herein is subject to change without notice.
5
2001-11-14