Power Relays ( Over 2 A )
DW RELAYS
Product Catalog
2023.4
Power Relays ( Over 2 A )
DW RELAYS
1 Form A 8 A/16 A, Small, Polarized power relays ( latching type )
Protective construction
:
Flux-resistant type
24
10
15.8
FEATURES
● Low profile type available ( height: 15.8 mm )
● Reflow possible ( Pin-in-Paste )
● Conforms to various safety standards ( UL/
C-UL, VDE, CQC )
10
18.8
Low profile type
(
Inrush type
)
24
10
18.8
24
● Inrush type available, TV-8 rating ( UL/C-UL
approved )
● IEC60335-1* compliant type available, PTI
325V ( VDE approved )
● Compliant with IEC62368-1* ( VDE approved )
2
1
Reflow compatible type
(
Standard type
)
(
Standard & Inrush type
)
(
Unit
:
mm
)
IEC60335-1 compliant type
*1: Common safety standard for major electrical appliance
*2: Audio/video, information and communication technology
equipment - Part 1: Safety requirements
TYPICAL APPLICATIONS
● Smart meters
● Home appliances
● Various power supplies
● Lighting control equipment
● Industrial equipment
● Security equipment
ORDERING INFORMATION ( PART NO. )
ADW 1
Contact arrangement
1
:
1 Form A
Operating function
1
:
1 coil latching
2
:
2 coil latching
W
(
Rated coil voltage DC
)
03
:
3V, 05
:
5V, 06
:
6V
09
:
9V, 12
:
12V, 24
:
24V
Type classification
Contact capacity
(
Nil
:
Reflow compatible type
Nil
:
Standard type 8A
)
L
:
Low profile type
H
:
Inrush type
(
16A, Inrush current 100A
)
T
:
IEC60335-1 compliant type
“
and
Notes
:
1. L
” “
T
”
type are non-compliant reflow soldering.
(
2. Low profile type is available inrush type only
)
.
“
on
3. The suffix W
”
the part number is only displayed on the inner and outer packaging.
It is not displayed on the relay.
(
4. 5A 277V AC Inrush current 320A
)
compliant with Electronic ballast is also available.
5. Inrush type (20A) is also available.
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
ー1ー
Panasonic Industry Co., Ltd. 2023
ASCTB8E 202304
Power Relays ( Over 2 A ) DW RELAYS
TYPES
■ Standard type ( 8 A )
● Reflow compatible type
Contact arrangement
Rated coil voltage
3 V DC
5 V DC
1 Form A
6 V DC
9 V DC
12 V DC
24 V DC
Part No.
1 coil latching
ADW1103W
ADW1105W
ADW1106W
ADW1109W
ADW1112W
ADW1124W
2 coil latching
ADW1203W
ADW1205W
ADW1206W
ADW1209W
ADW1212W
ADW1224W
100 pcs.
500 pcs.
Standard packing
Inner carton
Outer carton
Note) Carton packing is standard. Tube packing type is also available. Please consult us for details.
● IEC60335-1 compliant type
Contact arrangement
Rated coil voltage
3 V DC
5 V DC
1 Form A
6 V DC
9 V DC
12 V DC
24 V DC
Part No.
1 coil latching
ADW1103TW
ADW1105TW
ADW1106TW
ADW1109TW
ADW1112TW
ADW1124TW
2 coil latching
ADW1203TW
ADW1205TW
ADW1206TW
ADW1209TW
ADW1212TW
ADW1224TW
100 pcs.
500 pcs.
Standard packing
Inner carton
Outer carton
Note) Carton packing is standard. Tube packing type is also available. Please consult us for details.
■ Inrush type ( 16 A )
● Inrush current 100 A, IEC60335-1 compliant type
Contact arrangement
Rated coil voltage
3 V DC
5 V DC
1 Form A
6 V DC
9 V DC
12 V DC
24 V DC
Part No.
1 coil latching
ADW1103HTW
ADW1105HTW
ADW1106HTW
ADW1109HTW
ADW1112HTW
ADW1124HTW
2 coil latching
ADW1203HTW
ADW1205HTW
ADW1206HTW
ADW1209HTW
ADW1212HTW
ADW1224HTW
100 pcs.
500 pcs.
Standard packing
Inner carton
Outer carton
Notes) 1: Carton packing is standard. Tube packing type is also available. Please consult us for details.
2: Please consult us for the reflow compatible type of inrush type.
● Inrush current 100 A, low profile type
Contact arrangement
Rated coil voltage
3 V DC
5 V DC
1 Form A
6 V DC
9 V DC
12 V DC
24 V DC
Note) Carton packing is standard.
Part No.
1 coil latching
ADW1103HLW
ADW1105HLW
ADW1106HLW
ADW1109HLW
ADW1112HLW
ADW1124HLW
2 coil latching
ADW1203HLW
ADW1205HLW
ADW1206HLW
ADW1209HLW
ADW1212HLW
ADW1224HLW
Standard packing
Inner carton
Outer carton
100 pcs.
500 pcs.
■ Compliant with Electronic ballast
Please contact our sales representative for 5 A 277 V AC ( Inrush current 320 A ) compliant with Electronic ballast.
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
ー2ー
Panasonic Industry Co., Ltd. 2023
ASCTB8E 202304
Power Relays ( Over 2 A ) DW RELAYS
RATING
■ Coil data
• Operating characteristics such as " Operate voltage " and " Release voltage " are influenced by mounting conditions or
ambient temperature, etc.
Therefore, please use the relay within ±5 % of rated coil voltage.
• " Initial " means the condition of products at the time of delivery.
● 1 coil latching
Rated coil
voltage
3 V DC
5 V DC
6 V DC
9 V DC
12 V DC
24 V DC
* Square, pulse drive
Set voltage*
( at 20 ℃ )
Reset voltage*
( at 20 ℃ )
Rated operating
current
( ±10 %, at 20 ℃ )
66.7 mA
Coil resistance
( ±10 %, at 20 ℃ )
45 Ω
125 Ω
180 Ω
405 Ω
720 Ω
2,880 Ω
Rated operating
power
Max. allowable
voltage
( at 20 ℃ )
Max. 80 % V
of rated coil
voltage
( Initial )
Max. 80 % V
of rated coil
voltage
( Initial )
40
mA
33.3 mA
22.2 mA
16.7 mA
8.3 mA
200 mW
110 % V of
rated coil
voltage
● 2 coil latching
Rated coil
voltage
3 V DC
5 V DC
6 V DC
9 V DC
12 V DC
24 V DC
* Square, pulse drive
Set voltage*
( at 20 ℃ )
Reset voltage*
( at 20 ℃ )
Rated operating
current
( ±10 %, at 20 ℃ )
Set coil
133.3 mA
80
mA
Reset coil
133.3 mA
80
mA
66.7 mA
44.4 mA
33.3 mA
16.7 mA
Coil resistance
( ±10 %, at 20 ℃ )
Set coil
22.5 Ω
62.5 Ω
90
360
1,440
Ω
Ω
Ω
202.5 Ω
Reset coil
22.5 Ω
62.5 Ω
90
360
1,440
Ω
Ω
Ω
202.5 Ω
Rated operating
power
Set coil
Reset coil
Max. allowable
voltage
( at 20 ℃ )
Max. 80 % V
of rated coil
voltage
( Initial )
Max. 80 % V
of rated coil
voltage
( Initial )
66.7 mA
44.4 mA
33.3 mA
16.7 mA
400 mW
400 mW
110 % V of
rated coil
voltage
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
ー3ー
Panasonic Industry Co., Ltd. 2023
ASCTB8E 202304
Power Relays ( Over 2 A ) DW RELAYS
■ Specifications
Item
Contact
arrangement
Contact resistance
( initial )
Contact material
Contact rating
( resistive )
Contact data
Max. switching
power ( resistive )
Max. switching
voltage
Max. switching
current
Min. switching load
( reference value ) *
1
Insulation resistance ( initial )
Dielectric
strength
( initial )
Surge
withstand
voltage
( initial ) *
2
Time
characteristics
( initial )
Shock
resistance
Vibration
resistance
Expected life
Between open
contacts
Between contact
and coil
Between contact
and coil
Set time
Reset time
Functional
Destructive
Functional
Destructive
Mechanical life
Conditions for
usage, transport
and storage*
3
1 Form A
Max. 100 mΩ ( by voltage drop 6 V DC 1 A )
AgSnO
2
type
8 A 250 V AC
2,000 VA
250 V AC
8 A ( AC )
100 mA 5 V DC
Min. 1,000 MΩ ( at 500 V DC, Measured portion is the same as the case of dielectric strength. )
1,000 V rms for 1 min ( detection current: 10 mA )
5,000 V rms for 1 min ( detection current: 10 mA )
16 A 277 V AC
4,432 VA
277 V AC
16 A ( AC )
Specifications
Standard type ( 8 A )
Inrush type ( 16 A )
12,000 V
Max. 15 ms at rated coil voltage ( at 20 ℃, without bounce )
Max. 15 ms at rated coil voltage ( at 20 ℃, without bounce )
100 m/s
2
( half-sine shock pulse: 11 ms, detection time: 10 µs )
1,000 m/s
2
( half-sine shock pulse: 6 ms )
10 to 55 Hz ( at double amplitude of 2 mm, detection time: 10 µs )
10 to 55 Hz ( at double amplitude of 3 mm )
Min. 10
6
ope. ( switching frequency: at 180 times/min )
Ambient temperature: −40 to +85 ℃
( −40 to +70 ℃ at our standard packing condition )
Humidity: 5 to 85 % RH ( Avoid icing and condensation )
Approx. 8 g ( Low profile type: Approx. 7.5 g )
Ambient temperature: −40 to +70 ℃ ( Over 8 A to 16 A )
( −40 to +70 ℃ at our standard packing condition ) ,
−40 to +85 ℃ ( Max. 8 A )
Humidity: 5 to 85 % RH ( Avoid icing and condensation )
Conditions
Unit weight
*1: This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2: Wave is standard shock voltage of ±1.2 × 50 µs according to JEC-212-1981
*3: For ambient temperature, please read " GUIDELINES FOR RELAY USAGE ".
■ Expected electrical life
Conditions: Switching frequency at 20 times/min
Type
Standard type
(8A)
Resistive load: Type
Resistive load:
IEC60335-1 compliant type
Resistive load
Switching capacity
8 A 250 V AC
5 A 250 V AC
8 A 250 V AC
Inrush type
( 16 A )
16 A 277 V AC
Inrush current 100 A 600 W 120 V AC
Number of operations
Min. 50 × 10
3
ope.
Min. 100 × 10
3
ope.
Min. 50 × 10
3
ope.
Min. 20 × 10
3
ope.
( switching frequency ON : OFF = 1 s : 5 s )
Min. 25 × 10
3
ope.
( switching frequency ON : OFF = 1 s : 59 s )
Tungsten load
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
ー4ー
Panasonic Industry Co., Ltd. 2023
ASCTB8E 202304