Solid State Contactors (Three-phase)
G3PB-2/-3
CSM_G3PB-2_-3_DS_E_2_1
Compact, Low-cost Solid State Contactors
of an Innovative Construction Ideal for
Three-phase Heaters
• Slim Units with three-phase output.
• Optimum heat sinks attach to models without built-in heat sinks.
• Compact design achieved by optimizing heat sink shape.
• DIN track mounting possible (when using the Y92B-P50 Heat
Sink) in addition to screw mounting.
• Comply with EN60947-4-3 (IEC947-4-3) UL508, and
CSA22.2 No. 14, and bear CE marking.
Refer to
Safety Precautions for All Solid State
Relays.
Model Number Structure
■
Model Number Legend
G3PB-@@@-@@-@
1
2 3 4
5 6
7
1. Basic Model Name
G3PB:
Solid State Relay
2. Rated Load Power Supply Voltage
2:
200 VAC
4:
400 VAC
3. Rated Load Current
15:
15 A
25:
25 A
35:
35 A
45:
45 A
4. Terminal Type
B:
Screw terminals
5. Single-phase/3-phase and Number of Elements for 3-phase
2:
3-phase, 2-element models
3:
3-phase, 3-element models
6. 3-phase Type
Blank:
Built-in heat sink
H:
No heat sink (“hockey puck” type)
7. Certification
VD:
Certified by UL, CSA, and VDE
1
G3PB-2/-3
Ordering Information
■
List of Models
Models with Built-in Heat Sinks
Number of
phases
3
Main circuit voltage
100 to 240 VAC
Zero cross
function
Yes
Applicable load current
(with Class-1 AC resistive load)
15 A max.
25 A max.
35 A max.
45 A max.
200 to 400 VAC
15 A max.
25 A max.
35 A max.
45 A max.
3
2
3
2
3
2
3
2
3
2
3
2
3
2
3
2
Number of
elements
Model
G3PB-215B-3-VD
G3PB-215B-2-VD
G3PB-225B-3-VD
G3PB-225B-2-VD
G3PB-235B-3-VD
G3PB-235B-2-VD
G3PB-245B-3-VD
G3PB-245B-2-VD
G3PB-415B-3-VD
G3PB-415B-2-VD
G3PB-425B-3-VD
G3PB-425B-2-VD
G3PB-435B-3-VD
G3PB-435B-2-VD
G3PB-445B-3-VD
G3PB-445B-2-VD
Note: 1.
The applicable load current depends on the ambient temperature. For details, refer to
Load Current vs. Ambient Temperature
in,
Engineering Data
on page 7.
2.
When ordering, specify the rated input voltage.
Models without Built-in Heat Sinks
Number of
phases
3
Main circuit voltage
100 to 240 VAC
Zero cross
function
Yes
Applicable load current
15 A max.
25 A max.
35 A max.
45 A max.
200 to 400 VAC
15 A max.
25 A max.
35 A max.
45 A max.
3
2
3
2
3
2
3
2
3
2
3
2
3
2
3
2
Number of
elements
Model
G3PB-215B-3H-VD
G3PB-215B-2H-VD
G3PB-225B-3H-VD
G3PB-225B-2H-VD
G3PB-235B-3H-VD
G3PB-235B-2H-VD
G3PB-245B-3H-VD
G3PB-245B-2H-VD
G3PB-415B-3H-VD
G3PB-415B-2H-VD
G3PB-425B-3H-VD
G3PB-425B-2H-VD
G3PB-435B-3H-VD
G3PB-435B-2H-VD
G3PB-445B-3H-VD
G3PB-445B-2H-VD
Note: 1.
The applicable load current depends on the heat sink that is connected and the ambient temperature. For details, refer to
Load Current
vs. Ambient Temperature
in,
Engineering Data
on page 7.
2.
When ordering, specify the rated input voltage.
Heat Sinks
Heat resistance (°C/W)
1.67
1.01
0.63
0.43
0.36
Y92B-P50
Y92B-P100
Y92B-P150
Y92B-P200
Y92B-P250
Model
■
Accessories (Order Separately)
Mounting Track
50 cm (1) x 7.3 mm (t)
1 m (1) x 7.3 mm (t)
1 m (1) x 16 mm (t)
PFP-50N
PFP-100N
PFP-100N2
2
G3PB-2/-3
Specifications
■
Ratings (at an Ambient Temperature of 25°C)
Operating Circuit (Common)
Item
Rated voltage
Operating voltage range
Rated input current
Must operate voltage
Must release voltage
Insulation method
Operation indicator
12 to 24 VDC
9.6 to 30 VDC
10 mA max. (at 24 VDC)
9.6 VDC max.
1 VDC min.
Phototriac
Yellow LED
Common
Main Circuit of Models with Built-in Heat Sinks
Item
Rated load voltage
Load voltage range
Applicable load current
(See note.)
Inrush current resistance
(peak value)
Permissible I
2
t
(half 60-Hz wave)
Applicable load
(with Class-1 AC resistive
load)
Item
Rated load voltage
Load voltage range
Applicable load current
(See note.)
Inrush current resistance
(peak value)
Permissible I
2
t
(half 60-Hz wave)
Applicable load
(with Class-1 AC resistive
load)
G3PB-
215B-3-VD
75 to 264 VAC
0.2 to 15 A at 40°C
150 A
(60 Hz, 1 cycle)
121 A
2
s
5.1 kW max.
(at 200 VAC)
0.2 to 25 A at 40°C
220 A
(60 Hz, 1 cycle)
260 A
2
s
8.6 kW
(at 200 VAC)
0.5 to 35 A at 25°C
440 A
(60 Hz, 1 cycle)
1260 A
2
s
12.1 kW max.
(at 200 VAC)
15.5 kW max.
(at 200 VAC)
0.5 to 45 A at 25°C
G3PB-
215B-2-VD
G3PB-
225B-3-VD
G3PB-
225B-2-VD
G3PB-
235B-3-VD
G3PB-
235B-2-VD
G3PB-
245B-3-VD
G3PB-
245B-2-VD
100 to 240 VAC
G3PB-
415B-3-VD
G3PB-
415B-2-VD
G3PB-
425B-3-VD
G3PB-
425B-2-VD
G3PB-
435B-3-VD
G3PB-
435B-2-VD
G3PB-
445B-3-VD
G3PB-
445B-2-VD
200 to 400 VAC
180 to 440 VAC
0.5 to 15 A at 40°C
220 A
(60 Hz, 1 cycle)
260 A
2
s
10.3 kW max.
(at 400 VAC)
260 A
2
s
17.3 kW max.
(at 400 VAC)
0.5 to 25 A at 40°C
0.5 to 35 A at 25°C
440 A
(60 Hz, 1 cycle)
1260 A
2
s
24.2 kW max.
(at 400 VAC)
31.1 kW max.
(at 400 VAC)
0.5 to 45 A at 25°C
Note:
The applicable load current depends on the ambient temperature. For details, refer to
Load Current vs. Ambient Temperature
in,
Engineering
Data
on page 7.
3
G3PB-2/-3
Main Circuit of Models without Built-in Heat Sinks
Item
Rated load voltage
Load voltage range
Applicable load current
(See note.)
Inrush current resistance
(peak value)
Permissible I
2
t
(half 60-Hz wave)
Applicable load
(with Class-1 AC resistive
load)
Item
Rated load voltage
Load voltage range
Applicable load current
(See note.)
Inrush current resistance
(peak value)
Permissible I
2
t
(half 60-Hz wave)
Applicable load
(with Class-1 AC resistive
load)
G3PB-215B- G3PB-215B- G3PB-225B- G3PB-225B- G3PB-235B- G3PB-235B- G3PB-245B- G3PB-245B-
3H-VD
2H-VD
3H-VD
2H-VD
3H-VD
2H-VD
3H-VD
2H-VD
100 to 240 VAC
75 to 264 VAC
0.2 to 15 A at 40°C
150 A
(60 Hz, 1 cycle)
121 A
2
s
0.2 to 25 A at 40°C
220 A
(60 Hz, 1 cycle)
260 A
2
s
0.2 to 35 A at 25°C
440 A
(60 Hz, 1 cycle)
1260 A
2
s
0.2 to 45 A at 25°C
The applicable load varies with the heat radiation of the Unit. Refer to page 7,
Engineering Data
for details.
G3PB-415B- G3PB-415B- G3PB-425B- G3PB-425B- G3PB-435B- G3PB-435B- G3PB-445B- G3PB-445B-
3H-VD
2H-VD
3H-VD
2H-VD
3H-VD
2H-VD
3H-VD
2H-VD
200 to 400 VAC
180 to 440 VAC
0.5 to 15 A at 40°C
220 A
(60 Hz, 1 cycle)
260 A
2
s
260 A
2
s
0.5 to 25 A at 40°C
0.5 to 35 A at 25°C
440 A
(60 Hz, 1 cycle)
1260 A
2
s
0.5 to 45 A at 25°C
Refer to page 7,
Engineering Data
for details.
Note:
The applicable load current depends on the heat sink that is connected and the ambient temperature. For details, refer to
Load Current vs.
Ambient Temperature
in,
Engineering Data
on page 7.
4
G3PB-2/-3
■
Characteristics
Models with Built-in Heat Sinks
Item
Operate time
Release time
Output ON voltage drop
Leakage current
(See note.)
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Ambient temperature
Ambient humidity
Weight
Certified standards
EMC
G3PB-
215B-3-VD
G3PB-
215B-2-VD
G3PB-
225B-3-VD
G3PB-
225B-2-VD
G3PB-
235B-3-VD
G3PB-
235B-2-VD
G3PB-
245B-3-VD
G3PB-
245B-2-VD
1/2 of load power source cycle + 1 ms max. (DC input)
1/2 of load power source cycle + 1 ms max. (DC input)
1.6 V (RMS) max.
10 mA (at 200 VAC)
100 MΩ min. (at 500 VDC)
2,500 VAC, 50/60 Hz for 1 min
Destruction: 10 to 55 to 10 Hz, 0.375–mm single amplitude (Mounted to DIN track)
Destruction: 294 m/s
2
Operating:
Storage:
Approx.
750 g
–30°C to 80°C (with no icing or condensation)
–30°C to 100°C (with no icing or condensation)
Approx.
750 g
Approx.
900 g
Approx.
750 g
Approx.
1,150 g
Approx.
900 g
Approx.
1,500 g
Approx.
1,150 g
Operating: 45% to 85%
UL508, CSA22.2 No. 14, EN60947-4-3 (IEC947-4-3)
(From April 1999)
Emission: EN55011 Group 1 Class B
Immunity: EN61000-6-2
3 times larger if the 2-element model is applied.
G3PB-
425B-3-VD
G3PB-
425B-2-VD
G3PB-
435B-3-VD
G3PB-
435B-2-VD
G3PB-
445B-3-VD
G3PB-
445B-2-VD
Note:
The leakage current of phase S will be approximately
Item
Operate time
Release time
Output ON voltage drop
Leakage current
(See note.)
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Ambient temperature
Ambient humidity
Weight
Certified standards
EMC
G3PB-
415B-3-VD
G3PB-
415B-2-VD
1/2 of load power source cycle + 1 ms max. (DC input)
1/2 of load power source cycle + 1 ms max. (DC input)
1.8 V (RMS) max.
20 mA (at 400 VAC)
100 MΩ min. (at 500 VDC)
2,500 VAC, 50/60 Hz for 1 min
Destruction: 10 to 55 to 10 Hz, 0.375–mm single amplitude (Mounted to DIN track)
Destruction: 294 m/s
2
Operating:
Storage:
Approx.
750 g
–30°C to 80°C (with no icing or condensation)
–30°C to 100°C (with no icing or condensation)
Approx.
750 g
Approx.
900 g
Approx.
750 g
Approx.
1,150 g
Approx.
900 g
Approx.
1,500 g
Approx.
1,150 g
Operating: 45% to 85%
UL508, CSA22.2 No. 14, EN60947-4-3 (IEC947-4-3)
Emission: EN55011 Group 1 Class B
Immunity: EN61000-6-2
3 times larger if the 2-element model is applied.
Note:
The leakage current of phase S will be approximately
5