SKiiP 1242 GB 120 - 407 CTV
Absolute Maximum Ratings
Symbol
V
isol
T
op
,T
stg
4)
Conditions
1)
Values
3000
-25...+85
1200
900
1200
-40...+150
1200
2400
8640
373
18
30
14
75
Units
V
°C
V
V
A
°C
A
A
A
2
kAs
V
V
kHz
kV/µs
AC, 1min
Operating / stor. temperature
IGBT and Inverse Diode
V
CES
5)
V
CC
Operating DC link voltage
I
C
IGBT
3)
T
j
IGBT + Diode
I
F
Diode
I
FM
Diode, t
p
< 1 ms
I
FSM
Diode, T
j
= 150 °C, 10ms; sin
2
I t (Diode) Diode, T
j
= 150 °C, 10ms
Driver
V
S1
Stabilized Power Supply
V
S2
Non-stabilized Power Supply
f
smax
Switching frequency
dV/dt
Primary to secondary side
SKiiPPACK
®
SK integrated intelligent
Power PACK
halfbridge
SKiiP
7,9)
1242 GB 120 - 407 CTV
Preliminary Data
Case S4
Characteristics
Symbol
11)
IGBT
V
(BR)CES
I
CES
V
TO
r
T
V
Cesat
V
Cesat
E
on
+ E
off
C
CHC
L
CE
Conditions
1)
min.
≥V
CES
−
−
−
−
−
−
−
−
−
−
−
−
−
−
−
−
−
typ.
−
−
60
−
−
−
−
−
5,6
4
−
−
−
0,91
1,0
−
−
−
max.
−
1,8
−
1,38
1,8
3,2
3,05
360/586
−
−
2,43
2,55
48
−
−
0,023
0,063
0,033
Units
V
mA
mA
V
mΩ
V
V
mJ
nF
nH
V
V
mJ
V
mΩ
°C/W
°C/W
°C/W
mA
mA
µs
A
A
°C
V
Driver without supply
V
GE
= 0,
T
j
= 25 °C
T
j
= 125 °C
V
CE
= V
CES
T
j
= 125 °C
T
j
= 125 °C
I
C
= 1000A,
T
j
= 125 °C
I
C
= 1000A,
T
j
= 25 °C
V
CC
=600/900V,I
C
=1200A
T
j
= 125 °C
per SkiiP, AC side
Top, Bottom
2)
Inverse Diode
V
F
= V
EC
I
F
= 1000A;
V
F
= V
EC
I
F
= 1000A;
E
on
+ E
off
I
F
= 1200A;
V
TO
T
j
= 125 °C
r
T
T
j
= 125 °C
Features
•
Short circuit protection, due to
evaluation of current sensor
signals
•
Isolated power supply
•
Low thermal impedance
•
Optimal thermal management
with integrated heatsink
•
Pressure contact technology
with increased power cycling
capability, compact design
•
Low stray inductance
•
High power, small losses
•
Over-temperature protection
1)
T
j
= 125 °C
T
j
= 25 °C
T
j
= 125 °C
2)
3)
4)
Thermal Characteristics
10)
R
thjs
per IGBT
10)
R
thjs
per Diode
6,10)
R
thsa
P16 heatsink; see case S4
Driver
I
S1
Supply current 15V-supply
I
S2
Supply current 24V-supply
t
interlock-driver
Interlock-time
SKiiPPACK protection
I
TRIPSC
Short circuit protection
I
TRIPLG
Ground fault protection
T
TRIP
Over-temp. protection
9)
U
DCTRIP
U
DC
-protection
Mechanical Data
M1
DC terminals, SI Units
M2
AC terminals, SI Units
©by
SEMIKRON
5)
6)
7)
290+580*f
s
/f
smax
+1,3*I
AC
/A
220+420*f
s
/f
smax
+1,0*I
AC
/A
3,3
1500
±
2%
-
115
±
5%
920
±
2%
4
8
−
−
28.01.99
6
10
8)
9)
10)
11)
Nm
Nm
T
heatsink
= 25 °C, unless
otherwise specified
CAL = Controlled Axial Lifetime
Technology (soft and fast)
without driver
Driver input to DC link/ AC
output to heatsink
with Semikron-DC link (low
inductance)
other heatsinks on request
C - Integrated current sensors
T - Temperature protection
V - 15 V or 24 V power supply
AC connection busbars must be
connected by the user; copper
busbars available on request
options available for driver:
U - DC link voltage sense
F – Fiber optic connector
“
s
” referenced to temperature
sensor
NPT-technology with homo-
genous current-distribution