Surge protection device - CN-LAMBDA/4-2.2-BB - 2800024
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Attachment plug with Lambda/4 technology as surge protection for coaxial signal interfaces. Connection: N
connectors socket-socket
Your advantages
Maintenance-free surge protection with LAMBDA/4 technology
Low protection level
High HF power in the kW range
Key Commercial Data
Packing unit
GTIN
GTIN
4046356367967
1 pc
Technical data
Dimensions
Height
Width
Depth
66 mm
26.1 mm
83 mm
Ambient conditions
Ambient temperature (operation)
Degree of protection
-40 °C ... 90 °C
IP68
General
Housing material
Color
Mounting type
Type
Direction of action
Brass (CuZn)
nickel
Connection-specific intermediate plugging
Attachment plug
Line-Shield/Earth Ground
10/29/2018 Page 1 / 3
https://www.phoenixcontact.com/pi/products/2800024
Surge protection device - CN-LAMBDA/4-2.2-BB - 2800024
Technical data
Protective circuit
IEC test classification
C2
C3
D1
VDE requirement class
C2
C3
D1
Nominal current I
N
Nominal discharge current I
n
(8/20) µs (line-earth)
Nominal discharge current I
n
(8/20) µs (line-shield)
Total surge current (8/20) µs
Total surge current (10/350) µs
Max. discharge current I
max
(8/20) µs maximum (line-earth)
Max. discharge current I
max
(8/20) µs maximum (line-shield)
Impulse discharge current (10/350) µs, peak value l
imp
Output voltage limitation at 1 kV/µs (line-earth) spike
Output voltage limitation at 1 kV/µs (line-shield) spike
Output voltage limitation at 1 kV/µs (line-earth) static
Output voltage limitation at 1 kV/µs (line-shield) static
Voltage protection level U
p
(line-earth)
Voltage protection level U
p
(line-shield)
Input attenuation aE, asym.
Frequency range
Standing wave ratio SWR in a 50 Ω system
Permissible HF power P
max
at VSWR = xx (50 ohm system)
Surge protection fault message
Impulse durability (line-earth)
Impulse durability (line-shield)
5 A (25 °C)
50 kA
50 kA
60 kA
20 kA
60 kA
60 kA
≤ 20 kA
≤ 12 V (6 kV / 3 kA)
≤ 12 V (6 kV / 3 kA)
≤ 12 V (6 kV / 3 kA)
≤ 12 V (6 kV / 3 kA)
≤ 12 V (6 kV / 3 kA)
≤ 12 V (6 kV / 3 kA)
typ. 0.05 dB (≤ 0.15 dB)
0.82 GHz ... 2.2 GHz
typ. 1.1 (≤ 1.20 (0.82 GHz...2.2 GHz))
≤ 500 W
≤ 4 kW (peak)
none
C2 - 10 kV/5 kA
D1 - 2.5 kA
C2 - 10 kV/5 kA
D1 - 2.5 kA
Connection data
Connection method
Connection method IN
Connection method OUT
N Connector
N connector, female
N connector, female
Standards and Regulations
Standards/regulations
Standards/specifications
IEC 61643-21
IEC 61643-21 2005
Drawings
10/29/2018 Page 2 / 3
https://www.phoenixcontact.com/pi/products/2800024
Surge protection device - CN-LAMBDA/4-2.2-BB - 2800024
Circuit diagram
λ/4
Phoenix Contact 2018 © - all rights reserved
http://www.phoenixcontact.com
PHOENIX CONTACT GmbH & Co. KG
Flachsmarktstr. 8
32825 Blomberg
Germany
Tel. +49 5235 300
Fax +49 5235 3 41200
http://www.phoenixcontact.com
10/29/2018 Page 3 / 3