MCC
TM
Micro Commercial Components
omponents
20736 Marilla Street Chatsworth
!"#
$
% !"#
182KD14JX*
thru
180LD14JX*
11 to 1000 Volts
Varistor
5.2 to 510 Joule
Features
•
•
•
•
•
High Surge, High Energy
Designed to be Operated Continuously Across AC Power Lines
No Derating Up to 85 Ambient
Available in Tape and Reel or Bulk Pack
UL Recognized File # E306895(UL1449) and E306942(UL1414)
Maximum Ratings
•
•
•
•
Operating Ambient Temperature Range: -55 to +85
Storage Temperature Range: -55 to +125
Temperature Coefficient ( V) of Clamping Voltage (V
C
) at
Specified Test Current:<0.05%/
Varistor voltage temperature coefficient:
Vb at 25 - Vb at 85
Vb at 25
x
1
x(100/
60
)
120
100
80
60
L: 20mm Min.
DIMENSIONS
Unit: mm
Size D max
H max
S
11
13
18
22
28
C/I/Y
13
15
19.5
23
30
D±
0.05
All
0.6
0.6
0.6
0.8
0.8
1
0.8
1
E±
1.0
All
5
5
5
7.5
7.5
10
7.5
10
40
20
Lead
05D
07D
-55
60
80
100
120
140
160
All
7.5
9
12.5
16.5
23
0
10D
14D
20D
AMBIENT TEMPERATURE (°C)
PERCENT OF RATED VALUE
CURRENT, ENERGY AND POWER DERATING
CURVE
Note :
'X' can be S, C, I or Y .
'S'
'C'
'I'
'Y'
denotes
denotes
denotes
denotes
straight lead
out crimped lead
inner crimped lead
kink lead
*
www.mccsemi.com
Revision: 2
1 of 6
2006/09/09
182KD14JX thru 180LD14JX
MCC
Withstanding Surge
Current 8/20us
Rated Wattage
Varistor Voltage
Maximum
Clamping
Voltage
V50A
(V)
2970
1815
1650
1500
1355
1290
1240
1120
1025
920
845
775
710
650
595
550
505
455
395
360
330
300
250
200
165
135
*135
*110
*93
*77
*65
*53
*43
*38
TM
Micro Commercial Components
Electrical Characteristics @ 25
O
C Unless Otherwise Noted
Maximum Allowable
Voltage
Part Number
ACrms
(V)
182KD14J X
112KD14J X
102KD14J X
911KD14J X
821KD14J X
781KD14J X
751KD14J X
681KD14J X
621KD14J X
561KD14J X
511KD14J X
471KD14J X
431KD14J X
391KD14J X
361KD14J X
331KD14J X
301KD14J X
271KD14J X
241KD14J X
221KD14J X
201KD14J X
181KD14J X
151KD14J X
121KD14J X
101KD14J X
820KD14J X
680KD14J X
560KD14J X
470KD14J X
390KD14J X
330KD14J X
270KD14J X
220KD14J X
180LD14J X
1000
680
625
550
510
485
460
420
385
350
320
300
275
250
230
210
195
175
150
140
130
115
95
75
60
50
40
35
30
25
20
17
14
11
DC
(V)
1465
895
825
745
670
640
615
560
505
460
418
385
350
320
300
275
250
225
200
180
170
150
125
100
85
65
56
45
38
31
26
22
18
14
10/1000us
(J)
510
310
283
255
235
233
230
225
215
205
190
175
155
140
130
115
105
99
84
78
70
65
53
44
36
28
20
16
14
11
9.5
7.8
6.3
5.2
2000
1000
0.1
6000
4500
0.6
1 time
(A)
2 times
(W)
(V)
1800(1620-1980)
1100(990-1210)
1000(900-1100)
910(819-1001)
820(738-902)
780(702-858)
750(675-825)
680(612-748)
620(558-682)
560(504-616)
510(459-561)
470(423-517)
430(387-473)
390(351-429)
360(324-396)
330(297-363)
300(270-330)
270(243-297)
240(216-264)
220(198-242)
200(180-220)
180(162-198)
150(135-165)
120(108-132)
100(90-110)
82(74-90)
68(61-75)
56(50-62)
47(42-52)
39(35-43)
33(30-36)
27(24-30)
22(20-24)
18(15-21)
V1mA
Maximum
Energy
*680K-180L Max. Clamping Voltage testing current 10A
.
www.mccsemi.com
Revision: 2
2 of 6
2006/09/09
182KD14JX thru 180LD14JX
MCC
Max.
Clamping Voltage
182KD14
152KD14
112KD14
102KD14
911KD14
821KD14
781KD14
751KD14
681KD14
621KD14
TM
Micro Commercial Components
V-I Curve (621K to 182K)
5000
Max.
Leakage Current
4000
3000
2000
V
1000
700
600
500
400
300
200
10
-6
Test current waveform
-6
-3
10 to 10 A: Direct current
-1
4
10 to 10 A: 8/20µs
10
-5
10
-4
10
-3
10
-2
10
-1
10
0
10
1
10
2
10
3
10
4
10
5
A
V-I Surge Life Time Ratings
(180L to 680K)
10000
10000
V-I Surge Life Time Ratings
(820K to182K)
1 time
2 times
1000
1 time
2 times
10 times
A
100
10 times
10 times
10 times
10 times
10
10 times
6
4
5
3
2
1000
10 times
10 times
10 times
3
2
A
100
10 times
10 times
10 times
6
4
5
10
20
1000
µs
Impulse Current – Amperes
Impulse Width – Micro seconds
100
10000
20
1000
µs
Impulse Current – Amperes
Impulse Width – Micro seconds
100
10000
www.mccsemi.com
Revision: 2
4 of 6
2006/09/09