Test disconnect terminal block, Connection method: Screw/plug-in connection, Cross section: 0.14 mm² - 6 mm²,
AWG: 26 - 10, Width: 6.2 mm, Color: gray, Mounting type: NS 35/7,5, NS 35/15
Key commercial data
Packing unit
Minimum order quantity
Weight per Piece (excluding packing)
Custom tariff number
Country of origin
11
50 1
15.6 GRM
85369010
Poland
Technical data
General
Number of levels
Number of connections
Color
Insulating material
Inflammability class according to UL 94
Maximum load current
Rated surge voltage
Surge voltage category
Insulating material group
Connection in acc. with standard
Nominal current I
N
Nominal voltage U
N
Open side panel
Insertion/withdrawal cycles mechanical
Surge voltage test setpoint
1
2
gray
PA
V0
28 A
6 kV
III
I
IEC 61984
28 A
500 V
ja
100
4.8 kV
31.10.2013 Page 1 / 24
https://www.phoenixcontact.com/us/products/3057432
Test disconnect terminal block - UTME 4-CT/1P - 3057432
Technical data
General
Result of surge voltage test
Conductor cross section tensile test
Tractive force setpoint
Conductor cross section tensile test
Tractive force setpoint
Conductor cross section tensile test
Tractive force setpoint
Tensile test result
Tight fit on carrier
Setpoint
Result of tight fit test
Conductor cross section short circuit testing
Short-time current
Conductor cross section short circuit testing
Short-time current
Conductor cross section short circuit testing
Short-time current
Short circuit stability result
Proof of thermal characteristics (needle flame) effective duration
Result of thermal test
Test specification, oscillation, broadband noise
Test spectrum
Test frequency
ASD level
Acceleration
Test duration per axis
Test directions
Oscillation, broadband noise test result
Test specification, shock test
Shock form
Acceleration
Shock duration
Number of shocks per direction
Test directions
Shock test result
Temperature index, insulating material (DIN EN 60216-1 (VDE 0304-21))
Static insulating material application in cold
Test passed
0.14 mm²
10 N
4 mm²
60 N
6 mm²
120 N
Test passed
NS 35
1N
Test passed
4 mm²
0.5 kA
4 mm²
0.15 kA
4 mm²
1.25 kA
Test passed
30 s
Test passed
DIN EN 50155 (VDE 0115-200):2008-03
Service life test category 1, class B, body mounted
f
1
= 5 Hz to f
2
= 150 Hz
0.02 g²/Hz
0.8 g
5h
X-, Y- and Z-axis
Test passed
DIN EN 50155 (VDE 0115-200):2008-03
Half-sine
5g
30 ms
3
X-, Y- and Z-axis (pos. and neg.)
Test passed
130 °C
-60 °C
31.10.2013 Page 2 / 24
https://www.phoenixcontact.com/us/products/3057432
Test disconnect terminal block - UTME 4-CT/1P - 3057432
Technical data
Dimensions
Width
Length
Height NS 35/7,5
Height NS 35/15
6.2 mm
86.5 mm
49.5 mm
57 mm
Connection data
Conductor cross section solid min.
Conductor cross section solid max.
Conductor cross section AWG/kcmil min.
Conductor cross section AWG/kcmil max
Conductor cross section stranded min.
Conductor cross section stranded max.
Min. AWG conductor cross section, stranded
Max. AWG conductor cross section, stranded
Conductor cross section stranded, with ferrule without plastic sleeve min.
Conductor cross section stranded, with ferrule without plastic sleeve max.
Conductor cross section stranded, with ferrule with plastic sleeve min.
Conductor cross section stranded, with ferrule with plastic sleeve max.
2 conductors with same cross section, solid min.
2 conductors with same cross section, solid max.
2 conductors with same cross section, stranded min.
2 conductors with same cross section, stranded max.
0.14 mm²
6 mm²
26
10
0.14 mm²
4 mm²
26
12
0.14 mm²
4 mm²
0.14 mm²
4 mm²
0.14 mm²
1.5 mm²
0.14 mm²
1.5 mm²
2 conductors with same cross section, stranded, TWIN ferrules with plastic
0.5 mm²
sleeve, min.
2 conductors with same cross section, stranded, TWIN ferrules with plastic
2.5 mm²
sleeve, max.
2 conductors with same cross section, stranded, ferrules without plastic
sleeve, min.
2 conductors with same cross section, stranded, ferrules without plastic
sleeve, max.
Connection method
Stripping length
Internal cylindrical gage
Screw thread
Tightening torque, min
Tightening torque max
0.14 mm²
1.5 mm²
Screw/plug-in connection
9 mm
A4
M3
0.6 Nm
0.8 Nm
31.10.2013 Page 3 / 24
https://www.phoenixcontact.com/us/products/3057432
Test disconnect terminal block - UTME 4-CT/1P - 3057432
Classifications
eCl@ss
eCl@ss 4.0
eCl@ss 4.1
eCl@ss 5.0
eCl@ss 5.1
eCl@ss 6.0
eCl@ss 7.0
eCl@ss 8.0
27141126
27141126
27141126
27141126
27141126
27141126
27141126
ETIM
ETIM 2.0
ETIM 3.0
ETIM 4.0
ETIM 5.0
EC000902
EC000902
EC000902
EC000902
UNSPSC
UNSPSC 6.01
UNSPSC 7.0901
UNSPSC 11
UNSPSC 12.01
UNSPSC 13.2
30211811
39121410
39121410
39121410
39121410
Approvals
Approvals
Approvals
UL Recognized / cUL Recognized / CSA / cULus Recognized
Ex Approvals
Approvals submitted
Approval details
31.10.2013 Page 4 / 24
https://www.phoenixcontact.com/us/products/3057432
Test disconnect terminal block - UTME 4-CT/1P - 3057432
Approvals
UL Recognized
mm²/AWG/kcmil
Nominal current IN
Nominal voltage UN
B
26-10
25 A
300 V
C
26-10
25 A
300 V
D
26-10
5A
600 V
cUL Recognized
mm²/AWG/kcmil
Nominal current IN
Nominal voltage UN
B
26-10
25 A
300 V
C
26-10
25 A
300 V
D
26-10
5A
600 V
CSA
mm²/AWG/kcmil
Nominal current IN
Nominal voltage UN
26-10
25 A
300 V
B
26-10
25 A
300 V
C
26-10
5A
600 V
D
cULus Recognized
Accessories
Accessories
Bridge
Connecting bridge - C-ME 4/2 - 3035759
Connection bridge, for connecting 2 test disconnect terminal blocks