28/07/2014
www.crouzet.com
83581 Telescopic top-mounted plunger Part number 835810
Compact dimensions
Contact element : IP67
Part numbers
Type
83 581 0
Telescopic top-mounted plunger
Features
Standard
Function
I (Changeover)
Specifications
Conformity to standards
Degree of protection IEC 60529
NFC 20030 class II
Outer casing : IP57
Contact element : IP67
Electrical characteristics
Assigned operating current (Ie)
Electrical endurance - Standard (operations)
Electrical endurance - Dual-current
Standard : 8 A - 250 VAC
Bi-niveau : 0,1 A - 250 VAC
8 A - 250 VAC : 40000
5 A - 250 VAC : 100000
This version is designed to operate both on dual-current (1 mA 4 V minimum) and medium-current (5A) circuits. However, a given
product should only be used to switch one type of circuit during its working life.
Connections
Connection
Flexible leads : PVC 3x1 mm
2
- Length 0.50 m - ext. Ø 2 mm (on the right or left)
Cable : 3x0.75 mm
2
- Length 0.50 m - ext. Ø 5 mm (on left only)
Mechanical characteristics
Minimum operating force (N)
Minimum total travel force (N)
Differential travel (mm)
Minimum operating travel mm
Maximum total travel (mm)
Mechanical life (operations)
Operating temperature (°C)
Weight (g)
5
20
1
2.5
5
10
5
-20 →+85
40
Connections
Wire output on right
Wire output on left
Cable output
D
G
C
Principles
Function
Single break two-way contact element (form C : changeover)
N
o
Legend
Black (common)
Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected
28/07/2014
Brown (NC)
Blue (NO)
www.crouzet.com
Dimensions (mm)
Product
83 581 0 / 83 581 8
N
o
Legend
R10 spherical
Nuts 14 across flats Thickness 2
Output on right
Output on left
Product adaptations
Length of cable/connector
Approvals
Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected