02/11/2015
www.crouzet.com
Electromechanical Cam Timer 882564 Part number 88256403
Relay output
Mono-function
Mono-range
Mono-voltage
Manual reset
Progress of cycle displayed
Output : 1,2 or 3 changeover contacts (max of 16 A per contact)
Mounting option
Part numbers
Type
88 256 403
882564
Voltage
127/230 V AC 50 Hz
Relay outputs
1 timed
Breaking capacity per contact
16 A
Version
30 min
Maximum available timing
28 min
Dial graduation
1 min
Specifications
Precision limit error
Timed two-pole
Thermal rating
Mechanical life (operations)
Rating (cos
φ =
0.41) 10
4
operations
Voltage variation at maximum temperature of 55
o
C
according to IEC 255 100
Absorbed power-motor
Operating factor
Temperature limits use (°C)
Temperature limits stored (°C)
Environmental protection Protected metal components -
Insulated motor coil
Vibration withstand on 3 axes (Veritas standard)
Dielectric test voltage according to IEC 255-5 or VDE
0435
Insulation according to standard VDE 0110 group C
Protection : terminal
Operating position- any
Connection : Tags
Connection : Motor leads
Mounting by screw
Weight (g)
±4%
1 or 2 or 3
20 A
> 10
7
16 A - 230 V
+10 % -15 % Un
3,1 VA cos
φ 0,8
100 %
-5→+70
-40→+80
4 G - 55 Hz
1000 V -
Un ≤ 60 V
380 V AC
440 V DC
IP10
6,35
250 mm
2 x M3 - 2 x M4
225 / 245
Accessories
Accessories
Invertor for DC supply 24-48 V DC
Invertor for DC supply 110-127 V DC
Code
84 861 501
84 861 503
Dimensions (mm)
Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected
02/11/2015
Dimensions (mm)
Panel cut-out
www.crouzet.com
Dimensions (mm)
Dimensions (mm)
Inverter for DC supply
84 861 501 : 24 48 V DC
84 861 503 : 110 127 V DC
Weight 150 g
48 V DC
84 861 503 : 110 127 V DC
Weight 150 g" class="link_produits thickbox"> Zoom