Provides efficient and craft-friendly cable preparation
Medium-density polyethylene jacket
Makes cable rugged and durable while being flexible and
easy to strip
Corning ALTOS
®
double-jacket dielectric cables are
designed for duct and aerial (lashed) installation. The
double-jacket construction adds a layer of protection for
harsh environments. The loose tube cable design pro-
vides stable performance over a wide temperature range
and is compatible with any telecommunications-grade
optical fiber.
Standards
Design and Test Criteria
ANSI/ICEA S-87-640
Telcordia GR-20
RDUP PE-90
Polyethylene (PE)
Outer Jacket
Ripcord
Dielectric Central
Element
Dielectric Strength
Members
Fiber
Buffer
Tube
Water-Swellable
Tape
Water-Swellable
Tape
Polyethylene (PE)
Inner Jacket
ALTOS Double-Jacket Dielectric Cables, 72 Fibers
| Photo PIM1322
Family Spec Sheet 0039_NAFTA_AEN
Page 1 | Revision date 2014-08-08
ALTOS Double-Jacket Dielectric Cables, 72 Fibers
| Photo PIM2220
ALTOS
®
Double-Jacket Dielectric Cables,
12-288 Fibers, Enhanced
Polyethylene (PE)
Outer Jacket
Ripcord
Dielectric Central
Element
Dielectric Strength
Members
Fiber
Water-Swellable
Tape
Buffer
Tube
Water-Swellable
Tape
Water-Swellable
Tape
Polyethylene (PE)
Inner Jacket
ALTOS Double-Jacket Dielectric Cables, 288 Fibers
| Photo PIM1327
ALTOS Double-Jacket Dielectric Cables, 288 Fibers
| Photo PIM2225
Specifications
Temperature Range
Storage
Installation
Operation
-40 °C to 70 °C (-40 °F to 158 °F)
-30 °C to 70 °C (-22 °F to 158 °F)
-40 °C to 70 °C (-40 °F to 158 °F)
*
Note: Corning recommends storing cable in a proper temperature environment prior to installation to allow the cable temperature to meet installation tempera-
ture range specifications for best installation results.
Max. Tensile Strength, Short-Term
Max. Tensile Strength, Long-Term
2700 N (600 lbf)
890 N (200 lbf)
Mechanical Characteristics Cable
Fiber Count
Maximum
Fibers per
Tube
12
12
12
Number of
Tube Posi-
tions
6
8
12
Number of
Weight
Active Tubes
1-6
8
12
114 kg/km
(76 lb/1000 ft)
146 kg/km
(98 lb/1000 ft)
224 kg/km
(150 lb/1000 ft)
Nominal
Outer Dia-
meter
12.5 mm
(0.49 in)
14.2 mm
(0.56 in)
17.7 mm
(0.70 in)
Min. Bend
Radius
Installation
188 mm
(7.4 in)
213 mm
(8.4 in)
213 mm
(8.4 in)
Min. Bend
Radius Ope-
ration
125 mm
(4.9 in)
142 mm
(5.6 in)
142 mm
(5.6 in)
12 - 72
96
144
Family Spec Sheet 0039_NAFTA_AEN
Page 2 | Revision date 2014-08-08
ALTOS
®
Double-Jacket Dielectric Cables,
12-288 Fibers, Enhanced
Mechanical Characteristics Cable
Fiber Count
Maximum
Fibers per
Tube
12
12
Number of
Tube Posi-
tions
18
24
Number of
Weight
Active Tubes
16 - 18
24
217 kg/km
(146 lb/1000 ft)
279 kg/km
(187 lb/1000 ft)
Nominal
Outer Dia-
meter
17.9 mm
(0.70 in)
20.1 mm
(0.79 in)
Min. Bend
Radius
Installation
269 mm
(10.6 in)
302 mm
(11.9 in)
Min. Bend
Radius Ope-
ration
179 mm
(7.0 in)
201 mm
(7.9 in)
192 - 216
288
Chemical Characteristics
RoHS
Free of hazardous substances according to RoHS 2002/95/
EG
Transmission Performance
Multimode
Fiber Core Diameter
(
µm
)
Fiber Category
Fiber Code
Performance Option Code
Wavelengths
(
nm
)
Maximum Attenuation
(
dB/km
)
Serial 1 Gigabit Ethernet
(
m
)
Serial 10 Gigabit Ethernet
(
m
)
Min. Overfilled Launch (OFL)
Bandwidth
(
MHz*km
)
Minimum Effective Modal
Bandwidth (EMB)
(
MHz*km
)
62.5
OM1
K
30
850/1300
3.4/1.0
300/550
33/-
200/500
220/-
50
OM2
T
31
850/1300
3.0/1.0
750/500
150/-
700/500
950/-
50
OM3
T
80
850/1300
3.0/1.0
1000/600
300/-
1500/500
2000/-
50
OM4
T
90
850/1300
3.0/1.0
1100/600
550/-
3500/500
4700/-
Family Spec Sheet 0039_NAFTA_AEN
Page 3 | Revision date 2014-08-08
ALTOS
®
Double-Jacket Dielectric Cables,
12-288 Fibers, Enhanced
Single-mode
Fiber Name
Fiber Category
Fiber Code
Performance Option Code
Wavelengths
(
nm
)
Maximum Attenuation
(
dB/km
)
Typical Attenuation*
(
dB/km
)
Fiber Name
Fiber Category
Fiber Code
Performance Option Code
Wavelengths
(
nm
)
Maximum Attenuation
(
dB/km
)
Typical Attenuation*
(
dB/km
)
SMF-28e+
®
fiber
G.652.D
E
00
1310/1383/1550
0.35/0.35/0.25
0.33/0.33/0.19
SMF-28
®
ULL
G.652
P
19
1310/1383/1550
0.33/-/0.19
0.31/-/0.17
SMF-28e+
®
fiber
G.652.D
E
01
1310/1383/1550
0.4/0.4/0.3
0.33/0.33/0.19
LEAF
®
G.655
F
01
1310/1383/1550
-/-/0.25
-/-/0.19
SMF-28e+
®
LL
G.652.D
L
22
1310/1383/1550
0.34/0.34/0.22
0.32/0.32/0.18
SMF-28
®
Ultra**
ClearCurve
®
XB**
G.652.D/G.657.A1 G.652.D/G.657.A1
Z
22
1310/1383/1550
0.34/0.34/0.22
0.32/0.32/0.18
H
01
1310/1383/1550
0.4/0.4/0.3
0.35/0.35/0.20
*
Typical attenuation values match the attenuation values listed in the optical fiber specifications. See
www.corning.com/opticalfiber
for Corning optical fiber
specifications. Better attenuation performance options are available for some fiber and cable types. Contact Customer Care for additional fiber options.
*
* SMF-28
®
Ultra and ClearCurve
®
XB fiber deliver up to 10x better macrobend loss performance compared to the G.652.D standard and up to 33 percent better
macrobend loss performance than the G.657.A1 standard for 10mm radii bends.
Family Spec Sheet 0039_NAFTA_AEN
Page 4 | Revision date 2014-08-08
ALTOS
®
Double-Jacket Dielectric Cables,
12-288 Fibers, Enhanced
Ordering Information |
Note: Contact Customer Care at 1-800-743-2675 for other options.
Corning Optical Communications LLC • PO Box 489 • Hickory, NC 28603-0489 USA