Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
9258 Coax - RG-8X Type
For more Information
please call
1-800-Belden1
Description:
RG-8X type, 16 AWG stranded (19x29) .058" bare copper conductor, gas-injected FPE insulation, bare
copper braid shield (95% coverage), PVC jacket.
Physical Characteristics (Overall)
Conductor
AWG:
# Coax AWG Stranding Conductor Material Dia. (in.)
1
16
19x29
BC - Bare Copper
.058
Total Number of Conductors:
1
Insulation
Insulation Material:
Insulation Material
Dia. (in.)
Gas-injected FPE - Foam Polyethylene .155
Outer Shield
Outer Shield Material:
Type Outer Shield Material Coverage (%)
Braid BC - Bare Copper
95
Outer Jacket
Outer Jacket Material:
Outer Jacket Material
PVC - Polyvinyl Chloride
Overall Cable
Overall Nominal Diameter:
0.242 in.
Mechanical Characteristics (Overall)
Operating Temperature Range:
UL Temperature Rating:
Bulk Cable Weight:
Max. Recommended Pulling Tension:
Min. Bend Radius/Minor Axis:
-40°C To +80°C
80°C (UL AWM Style 1354)
37 lbs/1000 ft.
75 lbs.
2.500 in.
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification:
CEC/C(UL) Specification:
AWM Specification:
EU CE Mark:
EU Directive 2000/53/EC (ELV):
EU Directive 2002/95/EC (RoHS):
EU RoHS Compliance Date (mm/dd/yyyy):
CM
CM
UL Style 1354 (30 V 80°C)
No
Yes
Yes
01/01/2004
Page 1 of 3
09-26-2012
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
9258 Coax - RG-8X Type
EU Directive 2002/96/EC (WEEE):
EU Directive 2003/11/EC (BFR):
CA Prop 65 (CJ for Wire & Cable):
MII Order #39 (China RoHS):
RG Type:
Yes
Yes
Yes
Yes
8/X
Flame Test
UL Flame Test:
UL1685 UL Loading
Suitability
Suitability - Indoor:
Suitability - Outdoor:
Suitability - Aerial:
Yes
Yes
Yes
Plenum/Non-Plenum
Plenum (Y/N):
No
Electrical Characteristics (Overall)
Nom. Characteristic Impedance:
Impedance (Ohm)
50
Nom. Inductance:
Inductance (µH/ft)
.065
Nom. Capacitance Conductor to Shield:
Capacitance (pF/ft)
24.8
Nominal Velocity of Propagation:
VP (%)
82
Nominal Delay:
Delay (ns/ft)
1.2
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/1000 ft)
4.3
Nominal Outer Shield DC Resistance:
DCR @ 20°C (Ohm/1000 ft)
3.3
Nom. Attenuation:
Freq. (MHz) Attenuation (dB/100 ft.)
1
10
50
100
200
400
700
900
1000
.3
.9
2.1
3.1
4.5
6.6
9.1
10.7
11.2
Max. Power Rating:
Freq. (MHz) Rating (W)
10
50
1000
370
Page 2 of 3
09-26-2012
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
9258 Coax - RG-8X Type
100
200
400
700
1000
250
190
110
75
60
Max. Operating Voltage - UL:
Voltage
300 V RMS
Put Ups and Colors:
Item #
9258 0091000
9258 010U1000
9258 010U500
9258 0101000
9258 010500
Notes:
C = CRATE REEL PUT-UP.
Putup
1,000 FT
1,000 FT
500 FT
1,000 FT
500 FT
Ship Weight
40.000 LB
39.000 LB
20.000 LB
40.000 LB
20.000 LB
Color
WHITE
BLACK
BLACK
BLACK
BLACK
C
C
Notes
Item Desc
RG-8X TYPE COAX
RG-8X TYPE COAX
RG-8X TYPE COAX
RG-8X TYPE COAX
RG-8X TYPE COAX
Revision Number: 1
© 2012 Belden, Inc
All Rights Reserved.
Revision Date: 09-20-2012
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications
described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not
ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express,
statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or
exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the
compliance date may be in stock at Belden facilities and in our Distributor’s inventory. The information provided in this Product Disclosure, and
the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden’s knowledge,
information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide
for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not
to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for
determining the applicability of legislation and regulations based on their individual usage of the product.
Page 3 of 3
09-26-2012