CPFE1000F Series
www.uk.tdk-lambda.com/cpfe
Industrial
Test
Broadcast
Comms
Renewable
1000W single output, conduction/
baseplate cooled power supply
Features
•
Fanless
•
Baseplate cooled
•
Wide range ac input
•
I²C interface
•
2 Year Warranty
Benefits
Longer field life and no fan noise
Conducts heat outside of the system
Supports global use
Allows remote monitoring
Low cost of ownership
Input
Input Voltage
Input Harmonics
Input Fuse
Earth Leakage
Current
90-265Vac
EN61000-3-2 compliant
Fast acting
(not user accessible)
1.5mA at 23Vac (50Hz)
Input Frequency
Power Factor
Inrush Current
47 - 63Hz
(440Hz with reduced PFC
- consult sales office
)
0.95 typical (meets EN61000-3-2)
<40A at 25°C and 230Vac (cold start)
(meets EN61000-3-3)
QUICK SELECTOR - example configurations
Output Voltage
12V
28V
48V
Adjstment Range
9.6 - 14.4V
22.4 - 33.6V
38.4 - 57.6V
Maximum Output Current
60A
36A
21A
Description
CPFE1000F-12
CPFE1000F-28
CPFE1000F-48
Global Signals
Remote on/off
Standby supply
Output good (ENA)
IOG Signal
Opto isolated, 2.5mA (10-14V) to enable power supply, less than 0.15mA (0.5V) to disable
12V±2V / 20mA isolated supply, not affected by remote on/off.
Open collector (10mA sink current). Low (on) when output is in regulation
Normal or abnormal operation of the power module can be monitored by using the IOG terminal. This signal
monitor output is located at secondary side (output side) and is an open collector output. This signal is LOW
when inverter is normally operating and HIGH when inverter stops or when inverter is operating abnormally.
(maximum sink current is 5mA, maximum applied voltage is 35V). See handbook for details.
By connecting the PC terminal of each CPFE1000Fxx, output current can be equally drawn from each unit. A
maximum of 6 units of the same model can be connected. See handbook for details.
Provides manufacturing location, date, serial number, part number, unit revision, output voltage & current read
back, base plate temperature, remote on/off, IOG, DC good and over temperature warning
Current Share (PC)
I²C
Isolation
Input to Output
Input to Earth
4.24kVdc
2.12kVdc
Output to Earth
500Vdc
CPFE1000F Series
1
Output Specification
Total Output Power
Turn on time
Efficiency
Hold up
Ripple and Noise
Voltage Setting Accuracy
Remote Sense
Minimum Load
Total Regulation
Transient Response
Recovery
Over Voltage Protection
Short Circuit Protection
Over Temperature Protection
1008W
1.5s max
79-86%
25ms
<1%
±2%
Yes
No
<4%
<10%
500µs
Yes
Yes
Yes
Continuous. (12V versions = 720W)
at 90Vac and 100% rated output power
typical (model dependent)
typcial at 230Vac, 100% load
pk-pk, using EIAJ test method & 20MHz bandwidth
(2% below 0°C)
at 50% load
Max 0.5V total line drop
Including Line (for 90-264Vac input change), Load (for 0-100% load change) and
Temperature (0-50°C).
of set voltage for 50% load change
(in 50µs within the range 25-100% load)
for recovery to 2% of set voltage
Auto recovery
Auto recovery after removal of short circuit
Auto recovery
Environment
Baseplate
Temperature
(CPFE1000F-28 and CPFE1000F-48, -40°C to 70°C below
170Vac input)
-40°C to 85°C operational
-40°C to 100°C storage (max 12 months).
Ambient Temperature See ‘Ambient Temperature Operating Limits’
Low Temp Startup
-40°C
20 - 95% RH non condensing
(non operating 10-95% RH)
Humidity
(PCB assembly protective coated)
Ambient Temperature Operating Limits
Model No
Input
Voltage
Derating
50°C 60°C 70°C 85°C Factor
720W
720W
864W
1008W
864W
1008W
576W
670W
720W
958W
720W
958W
360W 14.4W/°C
595W 5W/°C
14.4W/°C
883W 5W/°C
14.4W/°C
883W 5W/°C
Output Power
Shock
Vibration
Altitude
Pollution
Conforms to MIL-STD-810E/F, Method 516.5, Pro
I, IV, VI
Conforms to MIL-STD-810E, Method 514.4, Pro I,
Cat 1,9
-200 to 2000 metres operational (-200 to 5000m
storage/transportation)
Degree 2, Material group IIIb
85-170Vac
170-265Vac
85-170Vac
CPFE1000F-28
170-265Vac
85-170Vac
CPFE1000F-48
170-265Vac
CPFE1000F-12
720W
720W
1008W
1008W
1008W
1008W
Immunity EN61000-6-2:2005, EN60601-1-2:2001
Electrostatic Discharge
Electromagnetic Field
Fast / Burst Transient
Surge Immunity
Conducted RF Immunity
Power Frequency Magnetic Field
Voltage Dips, Variations, Interruptions
Ring Wave
Voltage Fluctuations
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
EN61000-4-11
EN61000-4-12
EN61000-4-14
Level 2
Level 3
Level 3
Level X
Level 3
Level 4
Class 3
Level 3
Class 3
Air discharge level 3, Contact discharge level 2
12V/m
Criteria
A
A
A
B
A
A
A
A
A
(better than level 4)
Common mode - 6kVac, Differential - 3kVac
12V
30A/m
Criteria B for 5 sec interruption
Common mode - 2.2kV, Differential - 1.1kV
Emissions EN61000-6-3:2007, EN60601-1-2:2001
Radiated Electric Field
Conducted Emissions
Conducted Harmonics
Flicker
EN55011, EN55022
EN55011, EN55022
MIL STD 461E/462D CE102
EN61000-3-2
EN61000-3-3
Class B
see application note for details.
Class B
Compliant - d
max
<4% only
2
CPFE1000F Series
Safety Approvals
IEC/EN 60950-1, UL60950-1 / CSA 22.2 No 60950-1
CE Mark (EN60950-1)
CB certificate and Report available on request
Notes
File E135494
LV Directive 2006/95/EC
Please check with technical sales for status of approvals
Outline & Connection Drawings
Output Signals
Housing: Molex 22-01-1102
crimps: 08-20-0064 (22-30 awg)
J2,J3
Function
Pin
1
+ Sense
2
- Sense
3
COM
4
-remote on/off
5
+remote on/off
6
Aux
7
Current share (PC)
8
Trim
9
ENA
10
IOG
ac input connector
Housing Tyco 350766-1
Crimp 3 off
926895-1 (24-18 awg)
926893-1 (*20-14 awg)
or equivalent
Earth Neutral
Live
dc output
M6 x 18 stud for +ve output
M6 x 18 stud for -ve output
M6 nut, spring washer and flat
washer supplied for each terminal
Maximum tightening torque 10Nm
I2C
Molex 22-01-2037
Pins: Molex 2759 series
Notes
1. Customer fixings 12 x M4 clearance holes
2. All tolerances +/-0.5mm
CPFE1000F Series
3
TDK-Lambda France SAS
ZAC des Delaches
CS 41077
9 rue Thuillere
91978 Villebon Courtaboeuf
France
Tel: +33 1 60 12 71 65
Fax: +33 1 60 12 71 66
france@fr.tdk-lambda.com
www.fr.tdk-lambda.com
TDK-Lambda UK Ltd.
Kingsley Avenue
Ilfracombe
Devon EX34 8ES
United Kingdom
Tel: +44 (0) 12 71 85 66 66
Fax: +44 (0) 12 71 86 48 94
powersolutions@uk.tdk-lambda.com
www.uk.tdk-lambda.com
Italy Sales Office
Via dei Lavoratori 128/130
20092 Cinisello Balsamo (MI)
Italy
Tel: +39 02 61 29 38 63
Fax: +39 02 61 29 09 00
info.italia@it.tdk-lambda.com
www.it.tdk-lambda.com
TDK-Lambda Ltd.
Kibbutz
Givat Hashlosha 48800
Israel
Tel: +9 723 902 4333
Fax: +9 723 902 4777
info@tdk-lambda.co.il
www.tdk-lambda.co.il
Netherlands
info@tdk-lambda.nl
www.tdk-lambda.nl
Russia
Technical Support:
St Petersburg
Tel: +7 (812) 6580463
Sales:
Moscow
info@tdk-lambda.ru
www.tdk-lambda.ru
TDK-Lambda Germany GmbH
Karl-Bold-Strasse 40
77855 Achern
Germany
Tel: +49 7841 666 0
Fax: +49 7841 5000
info.germany@de.tdk-lambda.com
www.de.tdk-lambda.com
Local Distribution
Austria Sales Office
Aredstrasse 22
2544 Leobersdorf
Austria
Tel: +43 2256 655 84
Fax: +43 2256 645 12
info.germany@de.tdk-lambda.com
www.de.tdk-lambda.com
Scandinavia Sales Office
Valdemarsgade 7
4100 Ringsted
Denmark
Tel: +45 24 63 95 65
Fax: +45 69 80 44 99
info@de.tdk-lambda.com
www.emea.tdk-lambda.com
Switzerland Sales Office
Bahnhofstrasse 50
8305 Dietlikon
Switzerland
Tel: +41 44 850 53 53
Fax: +41 44 850 53 50
info@de.tdk-lambda.com
www.de.tdk-lambda.com
CPFE1000F 71639 - Rev 3-November 2013
www.emea.tdk-lambda.com
4
CPFE1000F Series