ø30mm - TWTD Series
Switches & Pilot Devices
Switches & Pilot Devices
TWTD Series — Full Size NEMA Pushbuttons
Relays & Sockets
Signaling Lights
TWTD Series: Heavy duty switches built to last
Key features:
•
Variety of button sizes up to 2 9/16” (65mm)
•
Rugged construction includes chrome plated zinc locking ring die cast zinc
mounting threads, screw mounted contact blocks
•
LED or incandescent illumination
•
Transformer or full voltage
•
Transparent contact windows
•
Slow make, double break self-cleaning contacts
•
Modular construction for maximum flexibility
•
Double nickel plated terminal screws
•
Available assembled or as sub-components
•
Type 4x and IP65 watertight/oiltight panel
•
Large M3.5 screw terminals with captive sems plate
The rugged series of TWTD switches offers both variety and durability in an
attractive design.
With button sizes up to 2 9/16” (65mm), chrome plated zinc locking rings, die
cast zinc mounting threads, steel anti-rotation rings, and self cleaning contacts,
the TWTDs are here to stay.
The TWTD series also offers either LED or incandescent illumination in full volt-
age and transformer models.
Transparent contact windows allow the viewing of IDEC’s self cleaning slow-
make/slow-break contacts.
Regardless of your switching needs, the TWTD series provides the kind of long
lasting, industrial strength quality you’ve come to expect from IDEC.
Contactors
Timers
UL Listed
File No. E68961
File No. LR21451
Ref No. 117617MC
Certificate No.
2005010305145658
Circuit Breakers
Terminal Blocks
660
www.IDEC.com
Switches & Pilot Devices
Specifications
Conforming to Standards
EN60947-1, EN60947-5-1, VDE0660-200, UL508, CSA C22-2 No.14
ø30mm - TWTD Series
Switches & Pilot Devices
Approvals
CSA:
pushbuttons and selector switches: A600 pilot lights and illuminated pushbuttons, direct supply pilot lights and illuminated pushbut-
tons with integral transformer (100/110, 115, 120, 200/220, 230, 240, 380, 400/440, 480V)
UL:
pushbuttons and selector switches: A600 pilot lights and illuminated pushbuttons, direct supply pilot lights and illuminated pushbuttons
with integral transformer (100/110, 115, 120, 200/220, 230, 240, 380, 400/440, 480V)
TÜV:
pushbuttons and selector switches: A600=P600 (NO, NC)/Q600 (NO-EM, NC-LB) pilot lights and illuminated pushbuttons, direct supply
pilot lights and illuminated pushbuttons with integral transformer (100/110, 115, 120, 200/220, 230, 240, 380, 400/440, 480V)
Operation: –25 to +50°C (without freezing)
Storage: –40 to +70°C (without freezing)
10 to 55Hz, 98m/sec
2
(10g) conforming to IEC6068-2-6
980m/sec
2
(100g) conforming to IEC6068-2-7
Class 0 conforming to IEC60536
IP65 (from front of the panel) (conforming to IEC60529)
IP54 (key switches)
Type 1, 2, 3, 3R, 3S, 4, 4X, 5, 12, 13 (conforming to NEMA ICS6-110)
Momentary pushbuttons: 5,000,000 (900 operations per hour)
All other switches: 500,000
3 for switches not using a transformer
2 for switches using a transformer
Operating Temperature
Vibration Resistance
Shock Resistance
Electric Shock Protection
Degree of Protection
Mechanical Life
Pollution Degree
(conforming to IEC60947-1)
Signaling Lights
Relays & Sockets
Mechanical-Electrical Specifications
Rated Operational Characteristics
AC-15: A600 or Ue = 250V, le = 3A (NO, NC, NO-EM, NC-LB)
DC-13: P600 or Ue = 125V, le = 1.1A (NO, NC)
DC-13: Q600 or Ue = 125V, le = 0.9A (NO-EM, NC-LB)
600V
Less than 4kV, conforming to IEC60947-1
4kV for contact circuit
2.5kV for lamp circuit
10 Amp
5 mA at 3V AC/DC
Slow break NC or NO, self-cleaning
Flush and extended pushbuttons—with 1NO or 1NC contact: 6.2±2N (momentary),
7.0±2N (maintained)
Additional contacts—1NO or 1NC: +3.2N (momentary), + 3.3N (maintained)
Conforming to CENELEC EN50005
0.8 N m (7.1 in lb.)
10A 250V fuse conforming to IEC60269-1
Minimum 1 x 22 AWG, max. 2 x 14 AWG or 1 x 12 AWG
Initial contact resistance of 50mΩ or less
4mm (NO and NC)
2mm (NO-EM and NC-LB)
Incandescent: 1 W
LEDs: 6V: 17mA, 12V: 11mA, 24V: 11mA, / 120, 240V: 10mA
40 A (40 msec)
Silver
Rated Insulation Voltage
Rated Switching Overvoltage
Rated Impulse Withstanding Voltage
Rated Thermal Current
Minimum Switching Capacity
Contact Operation
Operating Force
Terminal Referencing
Recommended Terminal Torque
External Short-Circuit Protection
Applicable Wire Size
Contact Resistance
Contact Gap
Lamp Ratings
Maximum Inrush Current
Contact Material
Timers
Contactors
Terminal Blocks
Contact Ratings
Contact Ratings by Utilization Category IEC 60947-5-1
AC-15 (A600)
DC-13 (P600)
Contact Ratings by Utilization Category
Operational Voltage
AC 50/60 Hz
Operation Current
DC
AC-12 Control of resistive loads & solid state loads
AC-15 Control of electromagnetic loads (> 72VA)
DC-12 Control of resistive loads & solid state loads
DC-13 Control of electromagnets
24V
10A
10A
8A
5A
48V
—
—
5A
2A
50V
10A
7A
—
—
110V
10A
5A
2.2A
1.1A
220V
6A
3A
1.1A
0.6A
440V
2A
1A
—
—
Circuit Breakers