Features
•
•
•
•
•
•
•
AC and DC Models
Back−to−Back Dual SCRs (Non−Suffix)
Internal Snubbers on AC & DC Models
TRIAC Versions (T−Suffix)
Random Switching (R−Suffix)
MOSFET DC Versions (M−Suffix)
LED Input Status Indicator on Some Models
RS3 Series
Panel Mount, Heavy Duty, SPST−NO,
Solid State AC and DC Power Relays,
10 Amp to 75 Amp.
D31
8−32 Pan
Head Screw
Large
Saddle
Clamp
1.750 (44.45)
1.100 (27.94)
.187 (4.48)
Dia. Typ
2.250
(57.15)
1.700
(43.18)
1
2
1.875
(47.63)
Ratings
INPUT PARAMETERS
NTE TYPE No.
RS3−1D10−51
RS3−1D10−51R
RS3−1A10−52*
RS3−1A25−42
RS3−1D25−24T
RS3−1A40−22
RS3−1D40−41
RS3−1D40−21*
RS3−1D40−21R*
RS3−1A75−22
RS3−1D75−21*
RS3−1D75−41*
RS3−1D12−41M**
RS3−1D40−41M**
Control
Signal
Range
3−32VDC
3−32VDC
100−280VAC
90−280VAC
3−32VDC
90−280VAC
3−32VDC
3−32VDC
3−32VDC
90−280VAC
3−32VDC
3−32VDC
3.5−32VDC
3.5−32VDC
Must
Operate
Voltage
3VDC
3VDC
80VAC
90VAC
3VDC
90VAC
3VDC
—
—
90VAC
—
—
3.5VDC
3.5VDC
Must
Release
Voltage
1VDC MIN
1VDC MIN
20VAC MIN
10VAC MIN
1VDC
10VAC MIN
1VDC MIN
—
—
10VAC MIN
—
—
1VDC MIN
1VDC MIN
Input
Current
22mA MAX
3.4mA TYP
—
2mA MAX
4mA MAX
2mA MAX
4mA MAX
14mA MAX
34mA MAX
2mA MAX
34mA MAX
34mA MAX
1.6mA MAX
1.6mA MAX
−
4
3
+
.188 (4.77)
Small
Saddle
Clamp
6−32 Pan
Head Screw
1.000 (25.4)
.265 (6.73)
R Typ
.950
(24.13)
** Contains LED Input Status Indicator
** Does NOT meet CSA approval.
OUTPUT PARAMETERS
NTE TYPE No.
RS3−1D10−51
RS3−1D10−51R
RS3−1A10−52*
RS3−1A25−42
RS3−1D25−24T
RS3−1A40−22
RS3−1D40−41
RS3−1D40−21*
RS3−1D40−21R*
RS3−1A75−22
RS3−1D75−21*
RS3−1D75−41*
RS3−1D12−41M**
RS3−1D40−41M**
Line
Voltage
Range
24−240VAC
24−240VAC
24−330VAC
48−240VAC
48−280VAC
48−240VAC
80−530VAC
24−280VAC
24−280VAC
48−280VAC
24−280VAC
36−530VAC
0−100VDC
0−100VDC
Max
On−State
Current
10A
10A
10A
25A
25A
40A
40A
50A
45A
75A
75A
75A
12A
40A
Max
1−Cycle
Surge
40A
40A
40A
245
215
245
600
450
450
950
700
700
28
106
On−State
Voltage
Drop
1.5V
1.5V
1.5V
1.6V
1.6V
1.6V
1.6V
1.6V
1.6V
1.6V
1.6V
1.6V
1.6V
2.1V
.090 (2.28)
Products and specifications subject to change without notice
Electrical Specifications
Environmental Characteristics
Operating:
−40
°
C to +80
°
C
** Contains LED Input Status Indicator
** Does NOT meet CSA approval.
Note 1. Can be used with R95−186, R95−187 or NTE441A Heat Sink.
Note 2. Dust Cover R95−184 Available.
102
NTE Electronics, Inc.
D
Voice (973) 748−5089
D
FAX (973) 748−6224
D