SMD Power chokes- SPD Series
SPD series chokes For High Current Use
Features
1.Shielded construction.
2.High current rating up to DC 50Amp
3.High frequency range up to 5.0MHz
4.Ultra low buzz noise, due to composite construction.
Applications
Netebook/Deaktop/Server applications
low profile high current power supplise
Battery powered devices
DC/DC Converter for field programmable gate arrary (FPGA)
Product Identification
SPD 0735 – 1R2 M
SPD: SERIES NAME
0735:DIMENSION SIZE CODE
1R2: INDUCTANCE CODE.
M: TOLERANCE, J=5% K=10% M=20%.
Dimensions
(mm)
SERIES
SPD0718
SPD0724
SPD0730
SPD0735
SPD1040
SPD1338
SPD1350
SPD1367
A
6.8 max
6.8 max
6.8 max
6.8 max
10.2 max
12.9 max
12.9 max
12.9 max
B
7.3 max
7.3 max
7.3 max
7.3 max
11.5 max
13.8max
13.8max
13.8max
C
1.8 max
2.4 max
3.0max
3.5max
4.0max
3.8max
5.0max
6.7max
D
3.2±0.2
3.2±0.2
3.2±0.2
3.2±0.2
4.1±0.3
4.7±0.3
4.7±0.3
4.7±0.3
E
4.2 ref
4.2 ref
4.2 ref
4.2 ref
6.3 ref
8.4ref
8.4ref
8.4ref
F
1.3 ref
1.3 ref
1.3 ref
1.3 ref
2.2ref
2.4ref
2.4ref
2.4ref
RECOMMENDER P.C.B LAYOUT
SERIES
SPD0718
SPD0724
SPD0730
SPD0735
SPD1040
SPD1338
SPD1350
SPD1367
L
7.4
7.4
7.4
7.4
12.0
13.8
13.8
13.8
H
3.45
3.45
3.45
3.45
4.80
5.15
5.15
5.15
W
3.7
3.7
3.7
3.7
5.0
7.6
7.6
7.6
SPD 0718 Series
Electrical Characteristics
Part Number
SPD0718-R33M
SPD0718-R68M
SPD0718-R82M
SPD0718-1R0M
SPD0718-1R5M
SPD0718-2R2M
SPD0718-3R3M
SPD0718-4R7M
Inductance
L0 (uH)±20%
@200KHz/0.25V
0.33
0.68
0.82
1.00
1.50
2.20
3.30
4.70
DCR
(mΩ) max.
7.00
13.90
15.90
18.50
34.00
46.00
60.10
78.00
I rms
(A) typ.
12.00
9.00
8.00
7.00
6.00
5.00
3.25
3.00
I sat
(A) typ.
18.00
15.00
14.00
11.50
10.00
8.50
6.00
5.50
Note:
(1). All test data is referenced to 25℃ ambient.
(2). Operating Temperature Range-55℃ to +125℃.
(3). DC current(A)that will cause an approximate△T
of 40℃.
(4). DC current(A)that will cause Lo to drop approximately
20%.
(5). The part temperature(ambient + temp rise)should not exceed
125℃ under worst case operating conditions. Circuit design, component placement, PWB trace size and thickness, airflow and
other cooling provisions all affect the part temperature Part temperature should be verified in the end application.
Typical Performance Curves
100
10
Inductance (uH)
1. 0
0. 1
0
100
1000
10000
DC current(mA)
100000
Temperature rise
℃
80
70
60
50
40
30
20
10
0
3000
6000
9000
12000 15000 18000
DC current(mA)
SPD 0724 Series
Electrical Characteristics
Part Number
SPD0724-R47M
SPD0724-R56M
SPD0724-R68M
SPD0724-R82M
SPD0724-1R0M
SPD0724-1R5M
SPD0724-2R2M
SPD0724-3R3M
SPD0724-4R7M
SPD0724-6R8M
SPD0724-100M
Inductance
L0 (uH)±20%
@200KHz/0.25V
0.47
0.56
0.68
0.82
1.00
1.50
2.20
3.30
4.70
6.80
10.00
DCR
(mΩ) max.
6.50
7.50
9.40
11.80
14.20
21.20
34.00
51.60
63.00
95.00
129.00
I rms
(A) typ.
13.50
12.00
11.00
10.00
9.00
7.50
6.50
5.00
4.50
3.50
2.50
I sat
(A) typ.
21.00
19.00
18.00
17.00
16.00
13.00
11.00
9.00
7.00
6.00
5.00
Note:
(1). All test data is referenced to 25℃ ambient.
(2). Operating Temperature Range-55℃ to +125℃.
(3). DC current(A)that will cause an approximate△T
of 40℃.
(4). DC current(A)that will cause Lo to drop approximately
20%.
(5). The part temperature(ambient + temp rise)should not exceed
125℃ under worst case operating conditions. Circuit design, component placement, PWB trace size and thickness, airflow and
other cooling provisions all affect the part temperature Part temperature should be verified in the end application.
Typical Performance Curves
100
10
y
Inductance (uH)
100
1R5
1. 0
R47
0. 1
0
100
1000
10000
100000
DC current(mA)
Temperature rise
℃
80
70
60
50
40
30
20
10
0
100
1R5
R47
5000
10000
15000
20000
25000
DC current(mA)
SPD 0730 Series
Electrical Characteristics
Part Number
SPD0730-R22N
SPD0730-R33M
SPD0730-R47M
SPD0730-R56M
SPD0730-R68M
SPD0730-R82M
SPD0730-1R0M
SPD0730-1R5M
SPD0730-2R2M
SPD0730-2R5M
SPD0730-3R3M
SPD0730-4R7M
SPD0730-5R6M
SPD0730-6R8M
SPD0730-8R2M
SPD0730-100M
SPD0730-220M
Inductance
L0 (uH)±20%
@200KHz/0.25V
0.22
0.33
0.47
0.56
0.68
0.82
1.00
1.50
2.20
2.50
3.30
4.70
5.60
6.80
8.20
10.00
22.00
DCR
(mΩ) max.
3.10
3.90
4.20
5.30
5.50
8.00
10.00
15.00
20.00
22.00
30.00
40.00
54.00
60.00
68.00
105.00
230.00
I rms
(A) typ.
22.00
20.00
17.50
15.50
15.50
13.00
11.00
9.00
8.00
8.00
6.00
5.00
5.00
4.50
4.00
3.00
2.00
I sat
(A) typ.
34.00
28.00
24.00
23.00
22.00
19.00
17.00
15.00
12.00
11.00
10.00
8.00
7.50
7.00
6.00
5.50
3.00
Note:
(1). All test data is referenced to 25℃ ambient.
(2). Operating Temperature Range-55℃ to +125℃.
(3). DC current(A)that will cause an approximate△T
of 40℃.
(4). DC current(A)that will cause Lo to drop approximately
20%.
(5). The part temperature(ambient + temp rise)should not exceed
125℃ under worst case operating conditions. Circuit design, component placement, PWB trace size and thickness, airflow and
other cooling provisions all affect the part temperature Part temperature should be verified in the end application.
Typical Performance Curves
100
220
Inductance (uH)
10
1. 0
0. 1
0
80
70
60
50
40
30
20
10
0
1R5
R22
100
1000
DC current(mA)
10000
100000
Temperature rise
℃
220
1R5
R22
5000
10000
15000
20000
25000 30000
35000 40000
DC current(mA)
SPD 0735 Series
Electrical Characteristics
Part Number
SPD0735-R22N
SPD0735-R33M
SPD0735-R47M
SPD0735-R56M
SPD0735-R68M
SPD0735-R82M
SPD0735-1R0M
SPD0735-1R5M
SPD0735-2R2M
SPD0735-2R5M
SPD0735-3R3M
SPD0735-4R7M
SPD0735-5R6M
SPD0735-6R8M
SPD0735-8R2M
SPD0735-100M
SPD0735-220M
Inductance
L0 (uH)±20%
@200KHz/0.25V
0.22
0.33
0.47
0.56
0.68
0.82
1.00
1.50
2.20
2.50
3.30
4.70
5.60
6.80
8.20
10.00
22.00
DCR
(mΩ) max.
3.10
3.90
4.20
5.30
5.50
8.00
10.00
15.00
20.00
22.00
30.00
40.00
54.00
60.00
68.00
105.00
230.00
I rms
(A) typ.
22.00
20.00
17.50
15.50
15.50
13.00
11.00
9.00
8.00
8.00
6.00
5.50
5.00
4.50
4.00
3.00
2.00
I sat
(A) typ.
36.00
30.00
26.00
24.00
23.00
20.00
18.00
16.00
12.50
11.50
10.50
8.50
8.00
7.50
6.50
6.00
3.50
Note:
(1). All test data is referenced to 25℃ ambient.
(2). Operating Temperature Range-55℃ to +125℃.
(3). DC current(A)that will cause an approximate△T
of 40℃.
(4). DC current(A)that will cause Lo to drop approximately
20%.
(5). The part temperature(ambient + temp rise)should not exceed
125℃ under worst case operating conditions. Circuit design, component placement, PWB trace size and thickness, airflow and
other cooling provisions all affect the part temperature Part temperature should be verified in the end application.
Typical Performance Curves
100
y
220
Inductance (uH)
10
1. 0
0. 1
0
1R5
R22
100
1000
DC current(mA)
10000
100000
80
Temperature rise
℃
70
60
50
40
30
20
10
0
5000
10000 15000
20000 25000 30000
35000 40000
220
1R5
R22
DC current(mA)