OBID i-scan
®
INSTALLATION
ID ISC.PRH101-A
ID ISC.PRH101-B
ID ISC.PRH101-USB
final
public (B)
2006-07-06
M50800-2e-ID-B.doc
OBID i-scan
®
Installation
ID ISC.PRH101
Note
©
Copyright 2005 by
FEIG ELECTRONIC GmbH
Lange Strasse 4
D-35781 Weilburg-Waldhausen
Tel.: +49 6471 3109-0
http://www.feig.de
With the edition of this document, all previous editions become void. Indications made in this manual may be
changed without previous notice.
Copying of this document, and giving it to others and the use or communication of the contents thereof are forbidden
without express authority. Offenders are liable to the payment of damages. All rights are reserved in the event of the
grant of a patent or the registration of a utility model or design.
Composition of the information in this document has been done to the best of our knowledge. FEIG
ELECTRONIC GmbH does not guarantee the correctness and completeness of the details given in this
manual and may not be held liable for damages ensuing from incorrect or incomplete information. Since,
despite all our efforts, errors may not be completely avoided, we are always grateful for your useful tips.
The instructions given in this manual are based on advantageous boundary conditions. FEIG ELECTRONIC
GmbH does not give any guarantee promise for perfect function in cross environments and does not give
any guaranty for the functionality of the complete system which incorporates the subject of this document.
FEIG ELECTRONIC call explicit attention that devices which are subject of this document are not designed
with components and testing methods for a level of reliability suitable for use in or in connection with surgical
implants or as critical components in any life support systems whose failure to perform can reasonably be
expected to cause significant injury to a human. To avoid damage, injury, or death, the user or application
designer must take reasonably prudent steps to protect against system failures.
FEIG ELECTRONIC GmbH assumes no responsibility for the use of any information contained in this docu-
ment and makes no representation that they free of patent infringement. FEIG ELECTRONIC GmbH does
not convey any license under its patent rights nor the rights of others.
OBID
®
and OBID i-scan
®
are registered trademarks of FEIG ELECTRONIC GmbH.
I-CODE
®
is a registered trademark of Philips Electronics N.V.
Tag-it
TM
is a registered trademark of Texas Instruments Incorporated.
Bluetooth
®
is a registered trademark of Bluetooth SIG Inc.
FEIG ELECTRONIC GmbH
Page 2 of 19
M50800-2e-ID-B.doc
OBID i-scan
®
Installation
ID ISC.PRH101
Contents
1. Safety Instructions / Warning - Read before start-up !
2. Performance Features of the ID ISC.PRH101
4
5
2.1. Performance features .........................................................................................................5
2.2. Available Reader-Types......................................................................................................5
3. Control and Display Elements
6
3.1. Signal buzzer .......................................................................................................................6
3.2. Scan - button .......................................................................................................................6
3.3. LED .......................................................................................................................................7
4. Assembly and Wiring
8
4.1. Reader with asynchronous interface ID ISC.PRH101-A ..................................................8
4.1.1. Asynchronous interface RS232 .....................................................................................8
4.1.2. Supply voltage ...............................................................................................................9
4.2. Reader with Bluetooth™ interface ID ISC.PRH101-B.....................................................10
4.2.1. Bluetooth™(BT) interface ............................................................................................10
4.2.2. Supply voltage .............................................................................................................11
4.2.3. Charging the batteries .................................................................................................12
4.2.4. Reset - button (ID ISC.PRH101-B only) ......................................................................13
4.3. Reader with USB-interface ID ISC.PRH101-U .................................................................14
5. Technical Data
6. Approvals
15
17
6.1. USA (FCC) .........................................................................................................................17
6.2. USA (UL, ID ISC.PRH100 Type A and Type USB) ..........................................................17
6.3. Europe (CE).......................................................................................................................17
7. Appendix
19
7.1. Accessories .......................................................................................................................19
7.2. Scope of delivery...............................................................................................................19
FEIG ELECTRONIC GmbH
Page 3 of 19
M50800-2e-ID-B.doc
OBID i-scan
®
Installation
ID ISC.PRH101
1. Safety Instructions / Warning - Read before start-up !
•
•
•
The device may only be used for the intended purpose designed by for the manufacturer.
The operation manual should be conveniently kept available at all times for each user.
Unauthorized changes and the use of spare parts and additional devices which have not been
sold or recommended by the manufacturer may cause fire, electric shocks or injuries. Such
unauthorized measures shall exclude any liability by the manufacturer.
The liability-prescriptions of the manufacturer in the issue valid at the time of purchase are valid
for the device. The manufacturer shall not be held legally responsible for inaccuracies, errors,
or omissions in the manual or automatically set parameters for a device or for an incorrect
application of a device.
Repairs may only be executed by the manufacturer.
Installation, operation, and maintenance procedures should only be carried out by qualified
personnel.
Use of the device and its installation must be in accordance with national legal requirements
and local electrical codes .
When working on devices the valid safety regulations must be observed.
Special advice for carriers of cardiac pacemakers:
Although this device doesn't exceed the valid limits for electromagnetic fields you should keep
a minimum distance of 25 cm between the device and your cardiac pacemaker.
•
•
•
•
•
•
FEIG ELECTRONIC GmbH
Page 4 of 19
M50800-2e-ID-B.doc
OBID i-scan
®
Installation
ID ISC.PRH101
2. Performance Features of the ID ISC.PRH101
2.1. Performance features
The ID ISC.PRH101 are devices for contactless data exchange with common Transponder ac-
cording ISO 15693. The readers have an internal antenna and will be delivered ready for connec-
tion. The device is designed as a handheld.
An anti-collision function enables simultaneous reading of several transponders per second.
The Reader electronic is fitted in a plastic housing with a protection class IP30.
The Reader ID ISC.PRH101-A has an asynchronous RS232 interface, the ID ISC.PRH101-B has
an Bluetooth interface and the ID ISC.PRH101-USB has an USB interface.
2.2. Available Reader-Types
Following Reader-Types are available at present:
Reader-Types
ID ISC.PRH101-A
ID ISC.PRH101-B
ID ISC.PRH100-USB
Tabelle 1: Reader-Types
Description
asynchronous RS232 interface with internal antenna and
voltage supply by means of external 5 V DC/
power supply.
Bluetooth interface with internal antenna and
voltage supply by means of 4 rechargeable Mignon AA batteries
USB interface with internal antenna and
voltage supply by means of USB-High Powered Interface
FEIG ELECTRONIC GmbH
Page 5 of 19
M50800-2e-ID-B.doc