SBLP65 AC-DC Single-Output Series Data Sheet
65 Watts
Features
RoHS compliant for all six substances
Typical 80-85% efficiency
Quasi-resonant ZVS topology with synchronous
rectification
Compact size of 2” x 4” x 1.30”
65 Watts with only 4-5 CFM forced-air cooling
60 Watts with convection cooling
90-264 VAC wide-range input
FCC & CISPR 22, Class "B" – Conducted EMI
Height meets 1U chassis constraints
Two-year limited warranty
Safety Agency pending to UL60960-1, CSA 22.2 No.
60950-1-03, and TUV EN60950/IEC 60950-1
Compliance with EN 61000-4-2 level 4 (ESD),
EN 61000-4-3 (RF), EN 61000-4-4 level 3 (Fast
Transient/Burst), EN 61000-4-5 class 3 (Surge)
Applications
Telecom, datacom
Networking
Industrial
Consumer
Gaming
Description
The SBLP65 is a compact and efficient series of AC-DC power supplies suited for telecom, datacom, and many
other applications. The SBLP65 Series meets the international information technology safety standards with the CE-
Mark for the European Low Voltage Directive (LVD). Its high efficiency allows a very minimal power loss in end
equipment, resulting in higher reliability, ease of thermal management, and regulatory approvals for an
environmentally friendly end product.
Single-Output Model Selection
Model
Nominal
Output Voltage
(VDC)
3.3
5
12
15
24
48
Min-Max Output
Current (Amps),
Convection
0 - 11
0 - 11
0-5
0-4
0 - 2.5
0 - 1.25
Min-Max Output
Current (Amps),
1
Forced Air
0 - 11
0 - 11
0 - 5.4
0 - 4.3
0 - 2.7
0 - 1.35
Peak Output
Current
2
(Amps)
19
12
6.25
5
3.1
1.56
Total
Regulation
3
(%)
2
2
2
2
2
2
Ripple &
Noise mV
4
pk-pk %
1.5
1.0
1.0
1.0
1.0
1.0
SBLP65-1003G
SBLP65-1005G
SBLP65-1012G
SBLP65-1015G
SBLP65-1024G
SBLP65-1048G
1
4 CFM or 105 LFM (average measurement of six equally-distributed points through a 3.5" x 1.6" (9 cm x 4 cm cross-sectional area) with power
supply mounted on a 0.25" (6.35 mm) standoffs. Recommended airflow direction is from the AC input to the DC output.
2
Peak current duration for less than 30 seconds with a maximum duty cycle of 10%. During peak loading, output may exceed total regulation
limits.
3
At 25
C
ambient including voltage set point tolerance, line and load regulation
4
Maximum peak-to-peak noise at 20 MHz bandwidth measured at the end of a twisted pair cable across a bypass capacitor.
MCD10023 Rev. 1.7, 30-Mar-09
Page 1 of 6
www.power-one.com
SBLP65 AC-DC Single-Output Series Data Sheet
65 Watts
ELECTRICAL SPECIFICATIONS
Input Specifications
Parameter
AC Input Voltage
Range
DC Input Voltage
Range
Frequency
Power Factor
Conditions/Description
Continuous voltage range
For DC input applications, please consult
factory.
AC Input
Complies with EN61000-3-2 Standard for Line
Current Harmonics with input power less than
75 Watts, at <60W output power
At 90 VAC input and max rating
115 VAC, Max power, 25 °C
230 VAC, Max power, 25 °C
Input fuse
Efficiency
Non-user serviceable internally located AC
input line fuse is provided.
At maximum power, 110 VAC
Single output models above 24V output
Single output 12V model
Single output models below 12V
85
84
80
1.5
30
60
Amps
rms
A pk
A pk
A
47
50 - 60
63
Min.
90
Nom.
100 - 250
Max.
264
Units
VAC
VDC
Hz
Input current
Inrush current
%
%
%
MCD10023 Rev. 1.7, 30-Mar-09
Page 2 of 6
www.power-one.com
SBLP65 AC-DC Single-Output Series Data Sheet
65 Watts
Output Specifications
Parameter
Output power
Conditions/Description
With convection cooling
With 3 CFM forced-air cooling for single output
models
Vo1 output is adjustable -5/+10 % of nominal
Min.
1
1
Nom.
Max.
60
65
Units
Watts
Output DC voltages
Output DC current
Minimum load
Leakage current
Output ripple & noise
Overshoot
Load transient
Turn-On & Turn-Off
characteristics
1
A
A
mA
mV
pk-pk
%
%
Required to meet total regulation
At 264 VAC/60 Hz
1
0.75
1
Vo1 overshoot at turn-on
Vo1 deviation due to a 50 to 100%
load change at a rate of 1A/µs
Outputs turn ON monotonically at minimum
output current or at full load.
Outputs turn OFF monotonically at minimum
output current or at full load.
Time required for output within regulation after
initial application of AC input @ 90 VAC.
Time required for output voltage to rise from
10% to 90%.
Time Vo1 is required to stay within 95%
regulation after removal of AC measure from
the last peak of the AC line at 120 VAC and
max power.
Maximum compensation.
Phase margin.
Gain margin.
45
10
16
5
±5
Turn-on Delay
Turn-on Rise Time
Hold-up Time
3
20
Sec
ms
ms
Remote Sense
Control loop stability
500
mV
Degrees
dB
1
See Model Selection table.
Fault Protection
Parameter
Current Limit
Protection
Short-circuit Protection
OVP Trip
Conditions/Description
Protection is provided.
Provided with auto-recovery.
Vo1, 3.3 V
Vo1, 5 V
Vo1, 12 V
Vo1, 24 V
Vo1, 48 V
3.6
5.6
14
29
55
3.75
6.2
15.35
31.6
57.5
3.95
6.9
16.7
34.2
60
ADC
Min.
Nom.
Max.
Units
VDC
MCD10023 Rev. 1.7, 30-Mar-09
Page 3 of 6
www.power-one.com
SBLP65 AC-DC Single-Output Series Data Sheet
65 Watts
Isolation Requirements
Parameter
Input-to-Chassis
Input-to-Output
Output-to-Chassis
Conditions/Description
Min.
2121
4242
500
Nom.
Max.
Units
VDC
VDC
VDC
EMC Immunity
Parameter
ESD
RF Susceptibility
Fast Transient/Burst
Surge
RF Immunity
Magnetic Fields
Voltage Interruptions
Conditions/Description
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6.
EN 61000-4-8.
EN 61000-4-11.
Level 2.
Level 3.
Level 3.
Class 3.
Class 3.
EMC Emmisions
Parameter
FCC Part 15
CISPR 22
Conditions/Description
Conducted Class B, Radiated Class A.
Conducted Class B, Radiated Class A.
Environmental Specifications
Parameter
Cooling
Audible Noise
Operating Temp
-10 ºC to 50 ºC with linear derating to 50% at
70 ºC. Unit will start up at -10 ºC, but will not
meet all published specifications.
Operating.
Non-Operating.
-40
95% relative humidity @ 40 ºC, non-condensing
Operating: Random vibration; 5 to 500 Hz
(10 minutes, each axis).
Non-Operating: Random vibration; 5 to 500 Hz
(10 minutes, each axis).
Shock
Operating: half-sine, 11
±3
ms, 3-axis.
Non-Operating: half-sine, 11
±3
ms, 3-axis.
2.4
Grms
-10
50
Conditions/Description
Rated for convection and forced-air cooling.
0
70
dBA
ºC
Min.
Nom.
Max.
Units
Altitude
Storage Temp
Humidity
Vibration
10K
50K
85
ASL ft
ASL ft
ºC
6
15
40
Grms
G
G
MCD10023 Rev. 1.7, 30-Mar-09
Page 4 of 6
www.power-one.com
SBLP65 AC-DC Single-Output Series Data Sheet
65 Watts
Regulatory & Safety Approvals
Parameter
UL60950-1
CSA-C22.2,
No. 60950-1-03
EN 60950-1
/IEC 60950-1
CE Mark for LVD
CB Approval
Ground Continuity
Conditions/Description
3.3V and 5V single-output models are pending.
3.3V and 5V single-output models are pending.
3.3V and 5V single-output models are pending.
3.3V and 5V single-output models are pending.
3.3V and 5V single-output models are pending.
At 12 VAC.
40
A
Min.
Nom.
Max.
Units
Mechanical Specifications
Parameter
Dimensions
Length
Width
Height, including component or component lead
protrusion on the bottom of the PCB.
Power Density
Mounting
Input
Output
Remote Sense
Outline Drawing
Pins/Functions
Weight
Connector kit
Mounting distance
Consult factory
Distance from the bottom of the components or
component leads (solder side) or top of the
components (component side) to the
customer's metal chassis
2.87
mm
With forced-air cooling.
(Location/Hardware); see Outline Drawing.
(Location/Connector);
J1 - Molex 41791 series or equivalent
(Location/Connector);
J2 - Molex 41791 series or equivalent
Combined into J2, pins 5 & 6 for single-output
models.
See Mechanical Drawing.
0.115
kg
Conditions/Description
Min.
Nom.
Max.
101.6
50.8
33.02
4.81
Units
mm
mm
mm
W/cu in
Reliability
Parameter
Calculated MTBF
Demonstrated MTBF
Conditions/Description
Min.
250,000
550,000
Nom.
Max.
Units
Hours
Hours
MCD10023 Rev. 1.7, 30-Mar-09
Page 5 of 6
www.power-one.com