Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
9451 Multi-Conductor - Single-Pair Cables
For more Information
please call
1-800-Belden1
Description:
22 AWG stranded (7x30) TC conductors, polypropylene insulation, twisted pair, overall Beldfoil shield
(100% coverage), 22 AWG stranded TC drain wire, PVC jacket.
Physical Characteristics (Overall)
Conductor
AWG:
# Pairs AWG Stranding Conductor Material
1
22
7x30
TC - Tinned Copper
Total Number of Conductors:
2
Insulation
Insulation Material:
Insulation Material Wall Thickness (in.)
PP - Polypropylene .008
Outer Shield
Outer Shield Material:
Outer Shield Trade Name Type Outer Shield Material
Beldfoil®
Coverage (%)
Tape Aluminum Foil-Polyester Tape 100
Outer Shield Drain Wire AWG:
AWG Stranding Drain Wire Conductor Material
22
7x30
TC - Tinned Copper
Outer Jacket
Outer Jacket Material:
Outer Jacket Material
Nom. Wall Thickness (in.)
PVC - Polyvinyl Chloride .020
Overall Cable
Overall Nominal Diameter:
0.135 in.
Pair
Pair Color Code Chart:
Number Color
1
Black & Red
Mechanical Characteristics (Overall)
Operating Temperature Range:
UL Temperature Rating:
Bulk Cable Weight:
Max. Recommended Pulling Tension:
Min. Bend Radius/Minor Axis:
-20°C To +75°C
60°C
14 lbs/1000 ft.
27 lbs.
1.500 in.
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification:
CMR
Page 1 of 3
09-04-2012
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
9451 Multi-Conductor - Single-Pair Cables
CEC/C(UL) Specification:
EU CE Mark:
EU Directive 2000/53/EC (ELV):
EU Directive 2002/95/EC (RoHS):
EU RoHS Compliance Date (mm/dd/yyyy):
EU Directive 2002/96/EC (WEEE):
EU Directive 2003/11/EC (BFR):
CA Prop 65 (CJ for Wire & Cable):
MII Order #39 (China RoHS):
CMG
Yes
Yes
Yes
01/01/2004
Yes
Yes
Yes
Yes
Flame Test
UL Flame Test:
CSA Flame Test:
UL1666 Vertical Shaft
FT4
Plenum/Non-Plenum
Plenum (Y/N):
No
Electrical Characteristics (Overall)
Nom. Characteristic Impedance:
Impedance (Ohm)
45
Nom. Inductance:
Inductance (µH/ft)
.17
Nom. Capacitance Conductor to Conductor:
Capacitance (pF/ft)
35
Nom. Capacitance Cond. to Other Conductor & Shield:
Capacitance (pF/ft)
67
Nominal Velocity of Propagation:
VP (%)
66
Nominal Delay:
Delay (ns/ft)
1.5
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/1000 ft)
14.1
Nominal Outer Shield DC Resistance:
DCR @ 20°C (Ohm/1000 ft)
14.3
Max. Operating Voltage - UL:
Voltage
300 V RMS
Max. Recommended Current:
Current
2.9 Amps per conductor @ 25°C
Notes (Overall)
Notes:
The jacket and shield are bonded so both can be removed on automatic stripping equipment. Drain wire is inside foil shield.
For cross-connect use with 1814R (et. al.) Snake Cables.
Page 2 of 3
09-04-2012
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
9451 Multi-Conductor - Single-Pair Cables
Put Ups and Colors:
Item #
9451 N3UU1000
9451 N3U5000
9451 001U1000
9451 0015000
9451 002U1000
9451 0025000
9451 003U1000
9451 0035000
9451 004U1000
9451 0045000
9451 006U1000
9451 0065000
9451 007U1000
9451 0075000
9451 008T1000
9451 008U1000
9451 008U500
9451 008500
9451 0085000
9451 009U1000
9451 0095000
9451 010U1000
9451 0105000
Putup
1,000 FT
5,000 FT
1,000 FT
5,000 FT
1,000 FT
5,000 FT
1,000 FT
5,000 FT
1,000 FT
5,000 FT
1,000 FT
5,000 FT
1,000 FT
5,000 FT
1,000 FT
1,000 FT
500 FT
500 FT
5,000 FT
1,000 FT
5,000 FT
1,000 FT
5,000 FT
Ship Weight
16.000 LB
70.000 LB
16.000 LB
70.000 LB
16.000 LB
75.000 LB
16.000 LB
75.000 LB
16.000 LB
75.000 LB
16.000 LB
75.000 LB
16.000 LB
75.000 LB
16.000 LB
16.000 LB
8.500 LB
8.000 LB
75.000 LB
16.000 LB
75.000 LB
16.000 LB
75.000 LB
Color
GREEN, MIL
GREEN, MIL
BROWN
BROWN
RED
RED
ORANGE
ORANGE
YELLOW
YELLOW
BLUE, LIGHT
BLUE, LIGHT
VIOLET
VIOLET
GRAY
GRAY
GRAY
GRAY
GRAY
WHITE
WHITE
BLACK
BLACK
CN
CN
CN
CN
CN
CN
CN
CN
CN
CN
Notes
Item Desc
2 #22 PP FS PVC FR
2 #22 PP FS PVC FR
2 #22 PP FS PVC FR
2 #22 PP FS PVC FR
2 #22 PP FS PVC FR
2 #22 PP FS PVC FR
2 #22 PP FS PVC FR
2 #22 PP FS PVC FR
2 #22 PP FS PVC FR
2 #22 PP FS PVC FR
2 #22 PP FS PVC FR
2 #22 PP FS PVC FR
2 #22 PP FS PVC FR
2 #22 PP FS PVC FR
2 #22 PP FS PVC FR
2 #22 PP FS PVC FR
2 #22 PP FS PVC FR
2 #22 PP FS PVC FR
2 #22 PP FS PVC FR
2 #22 PP FS PVC FR
2 #22 PP FS PVC FR
2 #22 PP FS PVC FR
2 #22 PP FS PVC FR
Notes:
C = CRATE REEL PUT-UP.
N = FINAL PUT-UP LENGTH MAY VARY -0% TO +10% FROM LENGTH SHOWN.
Revision Number: 1
© 2012 Belden, Inc
All Rights Reserved.
Revision Date: 08-08-2012
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications
described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not
ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express,
statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or
exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the
compliance date may be in stock at Belden facilities and in our Distributor’s inventory. The information provided in this Product Disclosure, and
the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden’s knowledge,
information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide
for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not
to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for
determining the applicability of legislation and regulations based on their individual usage of the product.
Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC.
Page 3 of 3
09-04-2012