Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
1583A Multi-Conductor - Category 5e Nonbonded-Pair Cable
For more Information
please call
1-800-Belden1
Description:
24 AWG Solid Bare Copper Conductors, Polyolefin Insulation, Twisted pairs, Rip Cord, PVC Jacket.
Usage (Overall)
Suitable Applications:
Horizontal Gigabit Ethernet, 100BaseTX, 100BaseVG ANYLAN, 155ATM,
622ATM, NTSC/PAL Component or Composite Video, AES/EBU Digital Video,
RS-422
Physical Characteristics (Overall)
Conductor
AWG:
# Pairs AWG Stranding Conductor Material
4
24
Solid
BC - Bare Copper
Total Number of Conductors:
8
Insulation
Insulation Material:
Insulation Material
PO - Polyolefin
Outer Shield
Outer Shield Material:
Outer Shield Material
Unshielded
Outer Jacket
Outer Jacket Material:
Outer Jacket Material
PVC - Polyvinyl Chloride
Outer Jacket Diameter:
Nom. Dia. (in.)
0.190
Outer Jacket Ripcord:
Yes
Pair
Pair Color Code Chart:
Number Color
1
2
3
4
White/Blue Stripe & Blue
White/Orange Stripe & Orange
White/Green Stripe & Green
White/Brown Stripe & Brown
Mechanical Characteristics (Overall)
Storage Temperature Range:
Installation Temperature Range:
Operating Temperature Range:
Bulk Cable Weight:
-20°C To +75°C
0°C To +60°C
-20°C To +60°C
18 lbs/1000 ft.
Page 1 of 4
09-04-2012
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
1583A Multi-Conductor - Category 5e Nonbonded-Pair Cable
Max. Recommended Pulling Tension:
Min. Bend Radius/Minor Axis:
Min. Bend/Installation:
35 lbs.
1 in.
1.900 in.
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification:
NEC Articles:
CEC/C(UL) Specification:
Other Standards:
EU CE Mark:
EU Directive 2000/53/EC (ELV):
EU Directive 2002/95/EC (RoHS):
EU RoHS Compliance Date (mm/dd/yyyy):
EU Directive 2002/96/EC (WEEE):
EU Directive 2003/11/EC (BFR):
CA Prop 65 (CJ for Wire & Cable):
MII Order #39 (China RoHS):
Telecommunications Standards:
Other Specification:
CMR
800
CMR
ISO/IEC 11801 ed 2.1 (2008) Class D
Yes
Yes
Yes
01/01/2004
Yes
Yes
Yes
Yes
Category 5e - TIA 568.C.2
NEMA WC-63.1 Category 5e, UL Verified to Category 5e
Flame Test
UL Flame Test:
C(UL) Flame Test:
CSA Flame Test:
IEEE Flame Test:
UL1666 Vertical Riser
FT4
FT4
1202
Suitability
Suitability - Indoor:
Suitability - Outdoor:
Suitability - Aerial:
Suitability - Burial:
Sunlight Resistance:
Oil Resistance:
Non-halogenated:
Yes
No
No
No
No
No
No
Plenum/Non-Plenum
Plenum (Y/N):
No
Electrical Characteristics (Overall)
Nom. Mutual Capacitance:
Capacitance (pF/ft)
15
Maximum Capacitance Unbalance (pF/100 m):
Nominal Velocity of Propagation:
VP (%)
70
330
Maximum Delay:
Delay (ns/100 m)
Page 2 of 4
09-04-2012
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
1583A Multi-Conductor - Category 5e Nonbonded-Pair Cable
538 @ 100MHz
Max. Delay Skew:
Delay Skew (ns/100 m)
45
Maximum Conductor DC Resistance:
DCR @ 20°C (Ohm/100 m)
9.38
Max. Operating Voltage - UL:
Voltage
300 V RMS
Maximum DCR Unbalanced:
DCR Unbalance @ 20°C (%)
3
Electrical Characteristics-Premise (Overall)
Premise Cable Electrical Table 1:
Freq. (MHz) Max. Attenuation (dB/100 m) Min. NEXT (dB) Min. PSNEXT (dB) Min. ACR (dB) Min. PSACR (dB) Min RL (dB)
1
4
8
10
16
20
25
31.25
62.5
100
155
200
2.000
4.100
5.800
6.500
8.200
9.300
10.400
11.700
17.000
22.000
28.100
32.400
65.3
56.3
51.8
50.3
47.3
45.8
44.3
42.9
38.4
35.3
32.5
30.8
62.3
53.3
48.8
47.3
44.3
42.8
41.3
39.9
35.4
32.3
29.5
27.8
63.0
51.0
46.0
43.0
39.0
36.5
33.9
31.0
22.0
14.0
4.4
4.0
60.3
49.2
43.0
40.8
36.0
33.5
30.9
28.2
19.0
10.3
1.4
1.0
20.000
23.000
24.500
25.000
25.000
25.000
24.300
23.600
21.500
20.100
15.800
15.000
Premise Cable Electrical Table 2:
Freq. (MHz) Input (Unfitted) Imp. (Ohms) Min. ELFEXT (dB) Min. PSELFEXT (dB)
1
4
8
10
16
20
25
31.25
62.5
100
155
200
100 ± 15
100 ± 15
100 ± 15
100 ± 15
100 ± 15
100 ± 15
100 ± 15
100 ± 15
100 ± 15
100 ± 15
100 ± 25
100 ± 25
63.8
51.7
45.7
43.8
39.7
37.7
35.8
33.9
27.8
23.8
19.9
17.7
60.8
48.7
42.7
40.8
36.7
34.7
32.8
30.9
24.9
20.8
16.9
14.7
Notes (Overall)
Notes:
Jacket sequentially marked at 2 ft. intervals. Third party verified to ANSI/TIA-568-C.2, Category 5e.
Put Ups and Colors:
Item #
1583A 002U1000
1583A 0021000
1583A 003U1000
1583A 0031000
1583A 004U1000
1583A 0041000
1583A 005U1000
Putup
1,000 FT
1,000 FT
1,000 FT
1,000 FT
1,000 FT
1,000 FT
1,000 FT
Ship Weight
24.000 LB
21.000 LB
24.000 LB
21.000 LB
24.000 LB
21.000 LB
24.000 LB
Color
RED
RED
ORANGE
ORANGE
YELLOW
YELLOW
GREEN, DARK
C
C
C
Notes
Item Desc
CAT5E 4PR U/UTP CMR BOX
CAT5E 4PR U/UTP CMR REEL
CAT5E 4PR U/UTP CMR BOX
CAT5E 4PR U/UTP CMR REEL
CAT5E 4PR U/UTP CMR BOX
CAT5E 4PR U/UTP CMR REEL
CAT5E 4PR U/UTP CMR BOX
Page 3 of 4
09-04-2012
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
1583A Multi-Conductor - Category 5e Nonbonded-Pair Cable
1583A 0051000
1583A 006U1000
1583A 0061000
1583A 0061640
1583A 0063000
1583A 008U1000
1583A 0081000
1583A 0081640
1583A 0083000
1583A 009U1000
1583A 0091000
1583A 0093000
1583A 010U1000
1583A 0101000
1583A 012U1000
1583A 0121000
Notes:
C = CRATE REEL PUT-UP.
1,000 FT
1,000 FT
1,000 FT
1,640 FT
3,000 FT
1,000 FT
1,000 FT
1,640 FT
3,000 FT
1,000 FT
1,000 FT
3,000 FT
1,000 FT
1,000 FT
1,000 FT
1,000 FT
21.000 LB
24.000 LB
21.000 LB
34.440 LB
60.000 LB
21.000 LB
21.000 LB
34.440 LB
60.000 LB
24.000 LB
21.000 LB
60.000 LB
24.000 LB
21.000 LB
24.000 LB
21.000 LB
GREEN, DARK
BLUE, LIGHT
BLUE, LIGHT
BLUE, LIGHT
BLUE, LIGHT
GRAY
GRAY
GRAY
GRAY
WHITE
WHITE
WHITE
BLACK
BLACK
PINK
PINK
C
C
C
C
C
C
C
C
C
C
C
CAT5E 4PR U/UTP CMR REEL
CAT5E 4PR U/UTP CMR BOX
CAT5E 4PR U/UTP CMR REEL
CAT5E 4PR U/UTP CMR REEL
CAT5E 4PR U/UTP CMR REEL
CAT5E 4PR U/UTP CMR BOX
CAT5E 4PR U/UTP CMR REEL
CAT5E 4PR U/UTP CMR REEL
CAT5E 4PR U/UTP CMR REEL
CAT5E 4PR U/UTP CMR BOX
CAT5E 4PR U/UTP CMR REEL
CAT5E 4PR U/UTP CMR REEL
CAT5E 4PR U/UTP CMR BOX
CAT5E 4PR U/UTP CMR REEL
CAT5E 4PR U/UTP CMR BOX
CAT5E 4PR U/UTP CMR REEL
Revision Number: 4
© 2012 Belden, Inc
All Rights Reserved.
Revision Date: 07-10-2012
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications
described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not
ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express,
statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or
exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the
compliance date may be in stock at Belden facilities and in our Distributor’s inventory. The information provided in this Product Disclosure, and
the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden’s knowledge,
information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide
for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not
to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for
determining the applicability of legislation and regulations based on their individual usage of the product.
Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC.
Page 4 of 4
09-04-2012