D
7.5
(3.45)
±0.10
B
First LF
contact D
F
±0.10
C
Pitch=2
A
TECHNICALS FEATURES
A
E
Last LF
contact G
MATERIAL
INSULATOR : Special PPS (Polyphenylene Sulfide Fiberglass
filled thermoplastic) UL 94-V0
Radiation resistance
No humidity absorption
Oxygen free
4
=
2
5.5
=
LF contacts
number
nn
10
3.75
1.75
4
3
2
1
A
B
C
D
Note : PPS characteristics are recognized for space applications
CRIMPING SIGNAL CONTACTS :
Female :
Body
Socket body
FIXING HARDWARE :
Jackscrew :
Stainless steel
Copper alloy / Ni + Au 0.2µ
Beryllium copper / Ni + Au 1.25µ
Knurling
(3.5)
A
(A)
B
±0.10
(3.5)
CONNECTOR SERIES 220 FEMALE
Distance in
Length
mm between
in mm
axies
LF contacts reference
mark number
Fixing
hardware
M10
ELECTRICAL for LF Contacts
4
Hex.2
All contacts
Working voltage (sea level)
Proof voltage
Contact resistance (initially)
Insulation resistance
D
E
F
G
04
2
9
14
1
2
3
4
06
4
11
16
1
3
4
6
08
6
13
18
1
4
5
8
10
8
15
20
1
5
6
10
12
10
17
22
1
6
7
12
14
12
19
24
1
7
8
14
16
14
21
26
1
8
9
16
CUT A-A
18
16
23
28
1
9
10
18
20
18
25
30
1
10
11
20
(2.5)
22
20
27
32
1
11
12
22
24
22
29
34
1
12
13
24
26
24
31
36
1
13
14
26
28
26
33
38
1
14
15
28
30
28
35
40
1
15
16
30
32
30
37
42
1
16
17
32
34
32
39
44
1
17
18
34
LF contact C13064-P
36
34
41
46
1
18
19
36
type "C" to crimp
38
36
43
48
1
19
20
38
or to solder
40
38
45
50
1
20
21
40
scale : 3:1
42
40
47
52
1
21
22
42
44
42
49
54
1
22
23
44
46
44
51
56
1
23
24
46
48
46
53
58
1
24
25
48
50
48
55
60
1
25
26
50
52
50
57
62
1
26
27
52
54
52
59
64
1
27
28
54
Crimping following cable instruction ICLF01
Tools
56
54
61
66
1
28
29
56
LF contacts insertion & withdrawal tool
recommended
Daniels MH800 hand crimp tool
58
56
63
68
1
29
30
58
for LF
Positioner K1692 for Daniels MH800 tool
contacts
60
58
65
70
1
30
31
60
AWG22 crimp tool setting
This document and drawings, sketches, and schematic drawings are the property of
the NICOMATIC company. and no parts thereof may be reproduced and used without
Catalogue
Reference
the written consent of the owner. Law dated 11.03.1902
3 A max. @ 25°C
2.2 A max. @ 85°C
Tested at 800 V DC
Tested at 1200 V DC
max. 10 mΩ
1000 MΩ min
3
MECHANICAL for LF Contacts
Mechanical operations
Contact insertion and withdrawal force
Contact retention in insulator
Contact replacement in insulator
500 cycles min. up to 2500.
2 N max. / 0.2 N min.
10 N min.
3 cycles
ENVIRONMENTAL
M2
B
±0.10
(2.5)
Temperature range
Vibration severity
C
Shock severity
Solvent resistance
Salt spray test
Humidity test
From -60°C to +260°C
0.75mm, 10 g RMS 6 hours long random
with superimposed sinusoid. No intermittencies
measured when using an H.S.L.I.
(High Speed Logic Interrupt) detector with a
trip threshold of 2 ns.
100g for 6 ms
HcFc 141 bMGX (ATOCHEM) solvent
96 hrs
56 days @ 90% Humidity
2
Conductor
Jacket
0.9
2
1.1 max.
AWG 22
3D view
scale ; 1.5:1
Marking as referenced in the CMM catalogue pages 12 & 13
2 17/01/13
www.nicomatic.com
Mail : nicomatic@nicomatic.fr
Tel : +33 (0)4.50.36.13.85
Iss
Date
A.Z.
Drawn
Checked
N.P.
Approved
1
Page
1/1
C12935
MH800
C12929
Position 6
Item : Connector CMM220 female on cables AWG22,
nn LF contacts, M10
General
tolerance
Folder :
X:\Méthodes\Plans clients\Plans clients 2D\10 - CMM220\Connecteurs femelles\222C\222CnnM10_cl
:
222CnnM10
±0.2
A4