OM1805NKM OM1815NKM
OM1812NKM
HERMETIC TO-3 FIXED VOLTAGE REGULATORS
APPROVED TO DESC DRAWINGS
Three Terminal, Fixed Voltage, 1.5 Amp
Precision Positive Regulators In Hermetic
JEDEC TO-3 Package
FEATURES
•
•
•
•
•
•
Output Voltages: 5V, 12V, 15V
Output Voltages Set Internally to ±1%
Built-In Thermal Overload Protection
Short Circuit Current Limiting
Similar To Industry Standards 7805, 7812, 7815
Hi-Rel Screening Available
DESCRIPTION
These three terminal positive regulators are supplied in a hermetically sealed metal
TO-3 package. All protective features are designed into the circuit, including thermal
shutdown, current limiting and safe-area control. With heat sinking, they can deliver
over 1.5 amps of output current. These units feature internally trimmed output
voltages ±1% of nominal voltage. These units are ideally suited for Military
applications where a hermetically sealed package is required.
PART NUMBER DESIGNATOR
Standard Military Drawing Number
5962-8778201 YX
5962-8777601 YX
5962-8855301 YX
Omnirel Part Number
OM1805NKM
OM1812NKM
OM1815NKM
3.3
4 11 R0
3.3 - 51
OM1805NKM - OM1815NKM
ABSOLUTE MAXIMUM RATINGS
@ 25°C
Input Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +35 V
Operating Junction Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . - 55°C to + 150°C
Storage Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - 65°C to + 150°C
Typical Power/Thermal Charateristics:
Rated Power @ 25° C T
C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20W
T
A
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.3W
Thermal Resistance
q
JC
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3°C/W
q
JA
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29°C/W
a
ELECTRICAL CHARACTERISTICS 5 Volt
Parameter
Output Voltage
Symbol
V
OUT
V
IN
= 10V, I
o
= 500mA, -55°C T
A
125°C (unless otherwise specified)
Min.
4.92
Max.
5.08
5.15
Unit
V
V
Test Conditions
T
A
= 25°C
V
IN
= 7.5V to 20V
I
O
= 5mA to 1.0A, P < 20 W
•
4.85
Line Regulation
(Note 1)
(Note 4)
V
RLINE
V
IN
= 7.5V to 20V
5
mV
mV
mV
mV
mV
mV
mV
mV
mA
mA
mA
•
V
IN
= 8.0V to 12V
12
4
•
Load Regulation
(Note 1)
V
RLOAD
I
O
= 5mA to 1.5 Amp
I
O
= 5mA to 1.0Amp
I
O
= 250mA to 750 mA
10
12
•
•
25
6
15
6
Standby Current Drain
I
SCD
DI
SCD
(Line)
DI
SCD
(Load)
V
DO
I
O (pk)
I
DS
DV
IN
DV
OUT
N
O
DV
OUT
Dt
T
A
= 25°C,
DV
OUT
= 100mV, I
O
=
1.0A
T
A
= 25°C
V
IN
= 35V
1.5
I
O
= 5mA to 1000mA
V
IN
= 7.5V to 20V
Standby Current Drain
Change With Line
Standby Current Drain
Change With Load
Dropout Voltage
Peak Output Current
Short Circuit Current
(Note 2)
•
•
•
6.5
0.8
0.5
mA
2.5
3.3
1.2
V
A
A
A
dB
dB
•
f =120 Hz,
DV
IN
= 10V
(Note 3)
T
A
= 25°C, f =10 Hz to 100KHz
T
A
= 25°C, t = 1000 hrs.
66
2.8
3.3
Ripple Rejection
•
60
40
Output Noise Voltage
(Note 3)
Long Term Stability
(Note 3)
µV/V
RMS
75
mV
Notes:
1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used.
Changes in output voltage due to heating effects must be taken into account separately.
2. Short Circuit protection is only assured up to V
IN
= 35V.
3. If not tested, shall be guaranteed to the specified limits.
The • denotes the specifications which apply over the full operating temperature range.
4. Minimum load current for full line regulation = 5.0 mA.
3.3 - 52
OM1805NKM - OM1815NKM
ELECTRICAL CHARACTERISTICS 12 Volt
Parameter
Output Voltage
Symbol
V
OUT
V
IN
= 19V, I
o
= 500mA, -55°C T
A
125°C (unless otherwise specified)
Min.
11.88
Max.
12.12
12.36
Unit
V
V
Test Conditions
T
A
= 25°C
V
IN
= 14.5V to 27V
I
O
= 5mA to 1.0 A, P < 20W
•
11.64
Line Regulation
(Note 1)
(Note 4)
V
RLINE
V
IN
= 14.5V to 27V
18
mV
mV
mV
mV
mV
mV
mV
mV
mA
mA
mA
•
V
IN
= 16V to 22V
50
9
•
Load Regulation
(Note 1)
V
RLOAD
I
O
= 5mA to 1.5 Amp
I
O
= 5mA to 1.0 Amp
I
O
= 250mA to 750 mA
30
32
•
•
60
20
40
6.0
Standby Current Drain
I
SCD
DI
SCD
(Line)
DI
SCD
(Load)
V
DO
I
O (pk)
I
DS
DV
IN
DV
OUT
N
O
DV
OUT
Dt
DV
OUT
= 100mV, I
O
=
1.0A
T
A
= 25°C
V
IN
= 35V
I
O
= 5mA to 1000mA
V
IN
= 15V to 30V
Standby Current Drain
Change With Line
Standby Current Drain
Change With Load
Dropout Voltage
Peak Output Current
Short Circuit Current
(Note 2)
Ripple Rejection
•
•
•
•
1.5
6.5
0.8
0.5
mA
2.5
3.3
1.2
V
A
A
A
dB
dB
•
f =120 Hz,
DV
IN
= 10V
(Note 3)
T
A
= 25°C, f =10 Hz to 100KHz
T
A
= 25°C, t = 1000 hrs.
61
2.8
•
54
40
Output Noise Voltage
(Note 3)
Long Term Stability
(Note 3)
µV/V
RMS
120
mV
Notes:
1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used.
Changes in output voltage due to heating effects must be taken into account separately.
2. Short Circuit protection is only assured up to V
IN
= 35V.
3. If not tested, shall be guaranteed to the specified limits.
The • denotes the specifications which apply over the full operating temperature range.
4. Minimum load current for full line regulation = 5.0 mA.
3.3
MECHANICAL OUTLINE
1.53
REF.
0.875
MAX.
0.135
MAX.
0.450
0.250
0.312
MIN.
SEATING
PLANE
0.043
0.038
2 PLCS.
0.225
0.205
0.161
0.151
0.525 R.
MAX.
1.197
1.177
0.675
0.655
2
1
0.188 R.
MAX.
0.440
0.420
Pin Connection
Pin 1: Input
Pin 2: Output
Case: Ground
3.3 - 53
OM1805NKM - OM1815NKM
ELECTRICAL CHARACTERISTICS 15 Volt
Parameter
Output Voltage
Symbol
V
OUT
V
IN
= 23V, I
o
= 500mA, -55°C T
A
125°C (unless otherwise specified)
Min.
14.8
Max.
15.2
15.4
Unit
V
V
Test Conditions
T
A
= 25°C
V
IN
= 18.5V to 30V
I
O
= 5mA to 1.0 A, P < 20W
•
14.6
Line Regulation
(Note 1)
(Note 4)
V
RLINE
V
IN
= 17.5V to 30V
20
mV
mV
mV
mV
mV
mV
mV
mV
mA
mA
mA
•
V
IN
= 20V to 26V
50
15
•
Load Regulation
(Note 1)
V
RLOAD
I
O
= 5mA to 1.5 Amp
I
O
= 5mA to 1.0 Amp
I
O
= 250mA to 750 mA
25
35
•
•
75
21
45
6.0
Standby Current Drain
I
SCD
DI
SCD
(Line)
DI
SCD
(Load)
V
DO
I
O (pk)
I
DS
DV
IN
DV
OUT
N
O
DV
OUT
Dt
T
A
= 25°C,
DV
OUT
= 100mV, I
O
=
1.0A
T
A
= 25°C
V
IN
= 35V
1.5
I
O
= 5mA to 1000mA
V
IN
= 18.5V to 30V
Standby Current Drain
Change With Line
Standby Current Drain
Change With Load
Dropout Voltage
Peak Output Current
Short Circuit Current
(Note 2)
Ripple Rejection
•
•
•
6.5
0.8
0.5
mA
2.5
3.3
1.2
V
A
A
A
dB
dB
•
f =120 Hz,
DV
IN
= 10V
(Note 3)
T
A
= 25°C, f =10 Hz to 100KHz
T
A
= 25°C, t = 1000 hrs.
54
2.8
•
52
40
Output Noise Voltage
(Note 3)
Long Term Stability
(Note 3)
µV/V
RMS
150
mV
Notes:
1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used.
Changes in output voltage due to heating effects must be taken into account separately.
2. Short Circuit protection is only assured up to V
IN
= 35V.
3. If not tested, shall be guaranteed to the specified limits.
The • denotes the specifications which apply over the full operating temperature range.
4. Minimum load current for full line regulation = 5.0 mA.
TYPICAL PERFORMANCE CHARACTERISTICS
3.3
3.5
3
PEAK OUTPUT
2.5
DROPOUT VOLTAGE
100
RIPPLE REJECTION
T
j
= -55°C
2
Output Current (A)
2.5
1.5
2
T
j
= 25°C
I
OUT
= 500mA
Ripple Rejection (dB)
I
OUT
= 1A
80
V
OUT
= 5V
60
1.5
1
T
j
= 150°C
1
I
OUT
= 0A
40
V
IN
- V = 8V
DC
+3.5V
rms
I
OUT
= 1A
T
j
= 25°C
0.5
DV
OUT
= 100MV
0.5
0
0
20
DV
OUT
= 100mV
5
10
15
20
25
30
35
0
-75 -50 -25
0
25 50 75 100 125 150
0
10
100
1k
10k
100k
Input To Output Differential (V)
Junction Temperature (°C)
Frequency (Hz)