3120-F311-P7T1-W15QY2-0.6A

产品描述1 POLE(S), 0.6A, 250 V(AC), 50 V(DC), PANEL MOUNT, THERMAL CIRCUIT BREAKER,
产品类别电路保护    电路保护   
文件大小441KB,共5页
制造商E-T-A [E-T-A Circuit Breakers]
下载文档 详细参数 全文预览

3120-F311-P7T1-W15QY2-0.6A概述

1 POLE(S), 0.6A, 250 V(AC), 50 V(DC), PANEL MOUNT, THERMAL CIRCUIT BREAKER,

3120-F311-P7T1-W15QY2-0.6A规格参数

参数名称属性值
Objectid1297339592
Reach Compliance Codecompliant
执行器类型ROCKER
主体宽度21 mm
主体高度33 mm
主体长度或直径54 mm
电路功能MANUAL ON/OFF
电路保护类型THERMAL CIRCUIT BREAKER
环境特性CORROSSION RESISTANT
安装特点PANEL MOUNT
极数1
最高工作温度60 °C
最低工作温度-30 °C
物理尺寸54mm x 21mm x 33mm
额定分断能力6 A
额定电流0.6 A
额定电压(交流)250 V
额定电压(直流)50 V
参考标准CCC; CSA; UL; VDE
表面贴装NO
端子形状QUICK CONNECT

文档预览

下载PDF文档
Thermal Overcurrent Circuit Breaker 3120-F...
Description
An extremely versatile range of rocker switch/thermal circuit breakers
(S-type TO CBE to EN 60934 with trip free mechanism) offering the choice
of single pole, double pole with single pole protection, and double pole
with protection on both poles. Designed for snap-in panel mounting with
versions available for three different panel cut-out sizes. Illumination is
optional and there is a range of colours and markings for the rocker.
Add on modules:
Under voltage release coil (for double pole versions only).
Magnetic trip coil for short circuit protection.
Magnetic trip coil for remote relay trip.
Auxiliary contacts for status signalling.
Approved to CBE standard EN 60934 (IEC 60934).
Meets the requirements regarding fire resistance of EN 60335-1 : 2007-02
Safety of household and similar electrical appliances.
3120-F3...F5
Typical applications
Technical data
Motors, transformers, solenoids, extra low voltage wiring systems, office
machines, electro-medical equipment, power supplies, communications
systems, medical equipment to EN 60601.
Standard current ratings and typical internal resistance values
Current rating
(A)
0.1
0.2
0.3
0.4
0.5
0.6
0.8
1
1.2
1.5
2
2.5
3
3.5
Internal
resistance
per pole (Ω)
94
24
12
5.30
4.20
2.90
1.50
0.9
0.80
0.45
0.27
0.0785
0.0595
0.0565
Current rating
(A)
4
4.5
5
6
7
8
10
12
14
15
16
18
20
Internal
resistance
per pole (Ω)
0.0435
0.0435
0.0325
0.0215
0.0165
0.0165
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
Dielectric strength
(IEC 60664 and 60664A)
operating area
between poles (2-pole)
Insulation resistance
Interrupting capacity I
cn
3120-F7
2
For further details please see chapter: Technical Information
Voltage rating
AC 240 V; DC 50 V
(AC 415 V to special order)
(UL: AC 250 V; DC 50 V)
Current ratings
0.1...20 A
(up to 30 A to special order, single pole only)
Typical life
AC 240 V:
DC 50 V:
DC 28 V:
AC 415 V:
AC 240 V:
0.1...20 A
0.1...4 A
4.5...16 A
0.1...20 A
0.1...16 A
0.1...16 A
17...20 A
DC 50 V:
0.1...16 A
17...20 A
Ambient temperature
Insulation co-ordination
(IEC 60664 and 60664 A
1-pole
30,000 operations at 1 x I
N
, inductive
30,000 operations at 1 x I
N
, inductive
30,000 operations at 1 x I
N
, resistive
30,000 operations at 1 x I
N
, inductive
2-pole
10,000 operations at 1 x I
N
, inductive
50,000 operations at 1 x I
N
, inductive
30,000 operations at 1 x I
N
, inductive
50,000 operations at 1 x I
N
, inductive
10,000 operations at 1 x I
N
, inductive
-30...+60 °C (-22...+140 °F)
rated impulse
pollution
withstand voltage
degree
2.5 kV
2
reinforced insulation in operating area
Illumination voltage/power consumption
operating voltage
12 V DC
24 V DC
115 V AC
230 V AC
power consumption
Y+R
2 mA
2 mA
0.9 mA
0.9 mA
G
3.5 mA
3.5 mA
2.8 mA
2.8 mA
test voltage
AC 3,000 V
AC 1,500 V
> 100 MΩ (DC 500 V)
0.1...2 A 10 x I
N
2.5...20 A 250 A 2-pole, or 150 A 1-pole
Interrupting capacity (UL 1077)
I
N
1, 2-pole
1, 2-pole
Degree of protection
(IEC 60529/DIN 40050)
Vibration
0.1...20 A
0.1...20 A
U
N
AC 250 V
DC 50 V
I
nc
5000 A
1000 A
Approvals
Authority
VDE (EN 60934)
Voltage ratings
AC 240 V; DC 28 V
DC 50 V
DC 50 V
AC 250 V; DC 50 V
AC 250 V; DC 50 V
Current ratings
0.1...20 A
0.1...20 A
2-pole
0.1...10 A
1-pole
0.1...20 A
0.1...20 A
Shock
Corrosion
Humidity
Mass
UL, CSA
CCC
operating area IP40
(IP54 with water splash protection)
terminal area IP00
8 g (57-500 Hz), ± 0.61 mm (10-57 Hz)
to IEC 60068-2-6, test Fc
10 frequency cycles/axis
30 g (11 ms)
to IEC 60068-2-27, test Ea
96 hours at 5 % salt mist,
to IEC 60068-2-11, test Ka
240 hours at 95 % RH,
to IEC 60068-2-78, test Cab
approx. 33 g (double pole)
approx. 27 g (single pole)
Issue D
www.e-t-a.de
2
- 67
arduino平台的点阵驱动程序设计
硬件平台: 1、CooCox官方推出的Cookie板,该板基于32位ARM Cortex M0/3/4 MCU,完全兼容arduino,同时更加丰富了其接口功能。 2、基于arduino平台的8*8点阵,驱动芯片是DM163。 软件平台: ......
mcy_cool 单片机
LM4F231在IAR下的float变量问题
芯片用的LM4F231,集成开发环境IAR 6.3。 1:当float变量定义成局部变量时,变量值并且也没分配变量地址。该如何解决。 void main(void) { float f1=1.1, f2= 1.2; f1= f1*f2; ......
yjf256156 微控制器 MCU
电源电路要诀分享
电源电路要诀分享 作者:rainysky rainysky和坛友一起学习分享电源电路要诀,互相交流,促进提高,学以致用,提高技能.谢谢你的支持鼓励! 1.直流稳压电源的组成 直流电源很重要,电子 ......
木犯001号 电源技术
Wince下Flash开发
我在找到了一个flash播放器的源码,flash5的,移植了下,在wince6的平台下运行起来了,有图像,但没声音.有没有那个大侠有wince下的flash源码,能正常播放的,有声音和图片的.帮忙发给个给我!...
dsx_msp430 嵌入式系统
只想问一下~~~
不知ST有没有计划做网口+外部总线的STM32呢?呵呵 发点消息出来呀~~~,没的话,就转Ti去了,呵呵...
yellowcrab stm32/stm8
关于超声波的阻抗匹配的问题
本人最近搞得一个课题是 超声波多普勒流量计。关于超声波的发射电路 有一个阻抗匹配的问题。。不知道还有大神知道的。。求指导、、QQ287997679 不胜感激啊...
tuxiaoli20 模拟电子

 
EEWorld订阅号

 
EEWorld服务号

 
汽车开发圈

 
机器人开发圈

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程 索引文件: 1723  2375  1477  1444  1185  43  15  42  39  2 

器件索引   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

北京市海淀区中关村大街18号B座15层1530室 电话:(010)82350740 邮编:100190

电子工程世界版权所有 京B2-20211791 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号 Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved