3120-F324-H7T1-W19QG2-0.8A

产品描述2 POLE(S), 0.8A, 250 V(AC), 50 V(DC), PANEL MOUNT, THERMAL CIRCUIT BREAKER,
产品类别电路保护    电路保护   
文件大小441KB,共5页
制造商E-T-A [E-T-A Circuit Breakers]
下载文档 详细参数 全文预览

3120-F324-H7T1-W19QG2-0.8A概述

2 POLE(S), 0.8A, 250 V(AC), 50 V(DC), PANEL MOUNT, THERMAL CIRCUIT BREAKER,

3120-F324-H7T1-W19QG2-0.8A规格参数

参数名称属性值
Objectid1297345130
Reach Compliance Codecompliant
执行器类型ROCKER
主体宽度21 mm
主体高度33 mm
主体长度或直径56 mm
电路功能MANUAL ON/OFF
电路保护类型THERMAL CIRCUIT BREAKER
环境特性CORROSSION RESISTANT
安装特点PANEL MOUNT
极数2
最高工作温度60 °C
最低工作温度-30 °C
物理尺寸56mm x 21mm x 33mm
额定分断能力8 A
额定电流0.8 A
额定电压(交流)250 V
额定电压(直流)50 V
参考标准CCC; CSA; UL; VDE
表面贴装NO
端子形状QUICK CONNECT

文档预览

下载PDF文档
Thermal Overcurrent Circuit Breaker 3120-F...
Description
An extremely versatile range of rocker switch/thermal circuit breakers
(S-type TO CBE to EN 60934 with trip free mechanism) offering the choice
of single pole, double pole with single pole protection, and double pole
with protection on both poles. Designed for snap-in panel mounting with
versions available for three different panel cut-out sizes. Illumination is
optional and there is a range of colours and markings for the rocker.
Add on modules:
Under voltage release coil (for double pole versions only).
Magnetic trip coil for short circuit protection.
Magnetic trip coil for remote relay trip.
Auxiliary contacts for status signalling.
Approved to CBE standard EN 60934 (IEC 60934).
Meets the requirements regarding fire resistance of EN 60335-1 : 2007-02
Safety of household and similar electrical appliances.
3120-F3...F5
Typical applications
Technical data
Motors, transformers, solenoids, extra low voltage wiring systems, office
machines, electro-medical equipment, power supplies, communications
systems, medical equipment to EN 60601.
Standard current ratings and typical internal resistance values
Current rating
(A)
0.1
0.2
0.3
0.4
0.5
0.6
0.8
1
1.2
1.5
2
2.5
3
3.5
Internal
resistance
per pole (Ω)
94
24
12
5.30
4.20
2.90
1.50
0.9
0.80
0.45
0.27
0.0785
0.0595
0.0565
Current rating
(A)
4
4.5
5
6
7
8
10
12
14
15
16
18
20
Internal
resistance
per pole (Ω)
0.0435
0.0435
0.0325
0.0215
0.0165
0.0165
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
Dielectric strength
(IEC 60664 and 60664A)
operating area
between poles (2-pole)
Insulation resistance
Interrupting capacity I
cn
3120-F7
2
For further details please see chapter: Technical Information
Voltage rating
AC 240 V; DC 50 V
(AC 415 V to special order)
(UL: AC 250 V; DC 50 V)
Current ratings
0.1...20 A
(up to 30 A to special order, single pole only)
Typical life
AC 240 V:
DC 50 V:
DC 28 V:
AC 415 V:
AC 240 V:
0.1...20 A
0.1...4 A
4.5...16 A
0.1...20 A
0.1...16 A
0.1...16 A
17...20 A
DC 50 V:
0.1...16 A
17...20 A
Ambient temperature
Insulation co-ordination
(IEC 60664 and 60664 A
1-pole
30,000 operations at 1 x I
N
, inductive
30,000 operations at 1 x I
N
, inductive
30,000 operations at 1 x I
N
, resistive
30,000 operations at 1 x I
N
, inductive
2-pole
10,000 operations at 1 x I
N
, inductive
50,000 operations at 1 x I
N
, inductive
30,000 operations at 1 x I
N
, inductive
50,000 operations at 1 x I
N
, inductive
10,000 operations at 1 x I
N
, inductive
-30...+60 °C (-22...+140 °F)
rated impulse
pollution
withstand voltage
degree
2.5 kV
2
reinforced insulation in operating area
Illumination voltage/power consumption
operating voltage
12 V DC
24 V DC
115 V AC
230 V AC
power consumption
Y+R
2 mA
2 mA
0.9 mA
0.9 mA
G
3.5 mA
3.5 mA
2.8 mA
2.8 mA
test voltage
AC 3,000 V
AC 1,500 V
> 100 MΩ (DC 500 V)
0.1...2 A 10 x I
N
2.5...20 A 250 A 2-pole, or 150 A 1-pole
Interrupting capacity (UL 1077)
I
N
1, 2-pole
1, 2-pole
Degree of protection
(IEC 60529/DIN 40050)
Vibration
0.1...20 A
0.1...20 A
U
N
AC 250 V
DC 50 V
I
nc
5000 A
1000 A
Approvals
Authority
VDE (EN 60934)
Voltage ratings
AC 240 V; DC 28 V
DC 50 V
DC 50 V
AC 250 V; DC 50 V
AC 250 V; DC 50 V
Current ratings
0.1...20 A
0.1...20 A
2-pole
0.1...10 A
1-pole
0.1...20 A
0.1...20 A
Shock
Corrosion
Humidity
Mass
UL, CSA
CCC
operating area IP40
(IP54 with water splash protection)
terminal area IP00
8 g (57-500 Hz), ± 0.61 mm (10-57 Hz)
to IEC 60068-2-6, test Fc
10 frequency cycles/axis
30 g (11 ms)
to IEC 60068-2-27, test Ea
96 hours at 5 % salt mist,
to IEC 60068-2-11, test Ka
240 hours at 95 % RH,
to IEC 60068-2-78, test Cab
approx. 33 g (double pole)
approx. 27 g (single pole)
Issue D
www.e-t-a.de
2
- 67
招聘兼职电子工程师
现在做一个平台,想找人做电子电路控制部分。有兴趣的可以联系我。最好人在广州啦,方便沟通些。qq:2425910325...
念念 求职招聘
ce 6 eboot 下载NK 启动后挂了
平台2440 使用NBOOT+EBOOT 下载NK DNW信息如下 : Enter your selection: d INFO: Probe: DM9000 is detected. DM9000: MAC Address: 0:11:22:33:44:55 System ready! Prepari ......
easyhrh 嵌入式系统
单片机的C语言轻松入门
单片机的C语言轻松入门...
zhengda06 单片机
电子工程师 毕业3年,工资从5k到20k的经历
前一阵子从网上看到一篇文章说 一个美女程序员毕业3年半,工资从2k到8k,换了3个工作。看后颇有同感,一直想也写一篇自己的经历。     1〉我的背景:生于江南,自认为较有追求,本科是二本 ......
eeleader 工作这点儿事
求大神解释一下这个主程序什么意思?特别是标红的意思
main() { unsigned int tem_c=0; unsigned char B_k1=0,B_k2=0; for(tem_c=0;tem_cIDR&0x80)==0x80)B_k1=0; //PG7为高电平,未有按键 else if(B_k1==0)//PG6按下时,指示灯亮 { ......
KCP stm32/stm8
郭天祥AD09视频教程(全13部分)
百度云分享 ...
白手梦想家 PCB设计

 
EEWorld订阅号

 
EEWorld服务号

 
汽车开发圈

 
机器人开发圈

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程 索引文件: 1987  147  174  1063  2323  52  43  13  50  11 

器件索引   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

北京市海淀区中关村大街18号B座15层1530室 电话:(010)82350740 邮编:100190

电子工程世界版权所有 京B2-20211791 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号 Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved