C 091
C 091 B
Bayonet locking
Plastic locking ring
3 - 8, 12 and 14 positions for crimp and solder
IP 40
Internal strain relief
Male and female cable connectors straight and angled
Male and female receptacles for front and
rear panel mounting and PCB mounting
• Coloured back shells optional
• UL registered under file number E 63 093 UL
•
•
•
•
•
•
•
24
C 091 B
Characteristics
Standard
Characteristics
3
2+3
2
1
3
1
General Characteristics
Number of contacts
View on termination side
of male contact insert
Contact arrangement
Contact arrangement
Electrical Characteristics
Rated voltage
Rated voltage
Pollution degree
Installation category
Insulation group
Current rating
Insulation resistance
Contact resistance
Climatic Characteristics
Climatic category
Temperature range
Mechanical Characteristics
IP-degree
4
4
2 3
2
4
1
5
5
3
4
5
5 Stereo
5
Stereo
4
1
2
5
3
2
1
6
6
3
4
6
5
5
6
7
7
4
7
1
3
2
7
7
4
1
6
2
7
5
3
4
1
8
8
2
6
8
7
5
3
12
12
E
F
G
DC
M
K
H J
L
A
B
14
14
E
F
G
D C
B
L
O N A
M
K
H J
DIN EN
61076-2-106
IEC 60130-9
1)
IEC 60664-1
UL 1977
03-a
ü
ü
04-a
ü
ü
300 V ≃
1500 V
05-a
ü
05-b
ü
ü
100 V ≃
06-a
ü
ü
07-a
ü
07-b
ü
ü
08-a
ü
ü
12-a
ü
14-a
ü
300 V ≃
1500 V
1
I
II, 400 ≤ CTI < 600
100 V ≃
1200 V
150 V ≃
60 V
250 V
1200 V
Rated impulse withstand voltage IEC 60664-1
IEC 60664-1
IEC 60664-1
IEC 60664-1
IEC 60512-5-2
UL 1977
IEC 60512-3-1
IEC 60512-2-1
IEC 60668-1
IEC 60668-1
IEC 60529
25 N
90.oz
10 A / + 40 °C
7 A / + 40 °C
> 10
10
Ω
2)
<5mΩ
40 / 100 / 56
- 40 °C ... + 100 °C / - 40 °F ... + 212 °F
IP 40
please refer also to current derating curves page 59
3 A / + 40 °C /
+ 104 °F
Insertion and withdrawal forces IEC 60512-13-2
Mechanical operation
Materials
Housing material
Dielectric material
Contact plating
Further Characteristics
Termination technique
Wire gauge
IEC 60512-9-1
30 N
110.oz
35 N
125.oz
50 N
180.oz
55 N
200.oz
60 N
220.oz
50 N
180.oz
Silver ≥ 500 mating cycles
Gold ≥ 1000 mating cycles
brass or zinc die cast nickel plated or thermoplast
thermoplastic
silver plated / gold plated
3)
solder, crimp
solder: ≤ 0,5 mm
2
/ 20 AWG
crimp: 2 - 6 pol (excluding 5S): 0,09 - 1,00 mm
2
/ 28 - 18 AWG
crimp: 5S, 7, 7S and 8-pol.: 0,09 - 0,75 mm
2
/ 28 - 20 AWG
UL 94 V0
solder: ≤ 0,25 mm² /
24 AWG
crimp: 0,09-0,25 mm²
/ 28 – 24 AWG
Flammability
Locking system
bayonet
Caution:
Do not connect or disconnect under load. Metal housing parts shall be securely incorporated to protected ground.
1)
Edition 2000-05
2)
Under operating conditions >10
8
Ω
3)
Remark for gold plated contacts: In order to avoid brittle inter-metallic connections, gold-plated terminals have to be tin-plated in the solder area.
^
IEC 60 664 ^ DIN VDE 0110; IEC 60 512-x = DIN EN 60 512-x; IEC 60 130-9 ^ DIN EN 60 130-9; IEC 61076-2-106 ^ DIN EN 61076-2-106
=
=
=
25
C 091 B
Male cable connector | bayonet locking inside
(mateable with locking outside)
Part Number
crimp termination
T 3274 551
T 3324 551
T 3374 551
T 3394 551
T 3424 551
T 3434 551
T 3444 551
T 3524 551
T 3624 551
T 3644 551
T 3274 552
T 3324 552
T 3374 552
T 3394 552
T 3424 552
T 3434 552
T 3444 552
T 3524 552
T 3624 552
T 3644 522
T 3274 554
T 3324 554
T 3374 554
T 3394 554
T 3424 554
T 3434 554
T 3444 554
T 3524 554
T 3624 554
T 3644 554
67,5
(2.658)
44,5
(1.752)
No. of Part Number solder termination
cont. silver plating
Locking inside | straight
3
4
5
5S
2)
6
7
7
2)
8
12
14
3
4
5
5S
2)
6
7
7
2)
8
12
14
3
4
5
5S
2)
6
7
7
2)
8
12
14
T 3274 501
T 3324 501
T 3374 501
T 3394 501
T 3424 501
T 3434 501
T 3444 501
T 3524 501
T 3624 501
T 3644 501
T 3274 502
T 3324 502
T 3374 502
T 3394 502
T 3424 502
T 3434 502
T 3444 502
T 3524 502
T 3624 502
T 3644 502
T 3274 504
T 3324 504
T 3374 504
T 3394 504
T 3424 504
T 3434 504
T 3444 504
T 3524 504
T 3624 504
T 3644 504
T 3274 518
T 3324 518
T 3374 518
T 3394 518
T 3424 518
T 3434 518
T 3444 518
T 3524 518
T 3624 518
T 3644 518
T 3274 528
T 3324 528
T 3374 528
T 3394 528
T 3424 528
T 3434 528
T 3444 528
T 3524 528
T 3624 528
T 3644 528
T 3274 548
T 3324 548
T 3374 548
T 3394 548
T 3424 548
T 3434 548
T 3444 548
T 3524 548
T 3624 548
T 3644 548
gold plating
1)
Drawing
Fig. C 091B-9a
Figure
(Please order crimp contacts separately, see page 56)
for cable diameter 4-6mm
Fig. C 091B-10a
62
(2.441)
53
(2.087)
PG 9
for cable diameter 6-8mm
Fig. C 091B-11a
62
(2.441)
53
(2.087)
PG 7
for cable diameter 4-6mm
Locking inside | straight | full plastic
3
4
5
5S
2)
6
7
7
2)
8
12
14
T 3274 991
T 3324 991
T 3374 991
T 3394 991
T 3424 991
T 3434 991
T 3274 998
T 3324 998
T 3374 998
T 3394 998
T 3424 998
T 3434 998
Fig. C 091B-54a
(Please order crimp contacts separately, see page 56)
T 3274 951
T 3324 951
T 3374 951
T 3424 951
T 3434 951
T 3444 951
T 3524 951
ca. 72
(2.835)
50
(1.969)
Locking inside | right-angled
3
4
5
5S
2)
6
7
7
2)
8
12
14
T 3274 005
T 3324 005
T 3374 005
T 3394 005
T 3424 005
T 3434 005
T 3444 005
T 3524 005
T 3624 005
T 3644 005
T 3274 058
T 3324 058
T 3374 058
T 3394 058
T 3424 058
T 3434 058
T 3444 058
T 3524 058
T 3624 058
T 3644 058
(Please order crimp contacts separately, see page 56)
T 3274 055
T 3324 055
T 3374 055
T 3394 055
T 3424 055
T 3434 055
T 3444 055
T 3524 055
T 3624 055
T 3644 055
64,5
(2.539)
for cable diameter 4-6mm
C 091B-43a
Fig.
20
(DIA.788)
for cable diameter 4-6mm
26
1)
See remark page 25
2)
Contact arrangement acc. to DIN EN 61076-2-106 "0X-b"
36
(1.417)
20
(DIA.788)
20
(DIA.788)
20
(DIA.788)
20
(DIA.788)
C 091 B
Male cable connector | bayonet locking inside
(mateable with locking outside)
Assembly instruction
1)
, cable diameter 4-6mm
tightening torque 0,3Nm
2)
20
2,5
5
fold back
shielding
2,5
tightening torque 0,4Nm
20
Assembly instruction
1)
, cable diameter 4-6mm or 6-8mm
tightening torque 1Nm
tightening torque 0,3Nm
2)
20
2,5
5
fold back
shielding
2,5
tightening torque 0,4Nm
20
Assembly instruction
1)
, right-angled, can be keyed to 8 angle positions
tightening torque 0,4Nm
fold back
shielding
2)
32
32
2,5
2,5
5
1)
For further information see page 60
2)
Solder version only
27
C 091 B
Male cable connector | bayonet locking outside
(mateable with locking inside)
Part Number
crimp termination
T 3279 551
T 3329 551
T 3379 551
T 3399 551
T 3429 551
T 3439 551
T 3449 551
T 3529 551
T 3629 551
T 3649 551
T 3279 552
T 3329 552
T 3379 552
T 3399 552
T 3429 552
T 3439 552
T 3449 552
T 3529 552
T 3629 552
T 3649 552
T 3279 554
T 3329 554
T 3379 554
T 3399 554
T 3429 554
T 3439 554
T 3449 554
T 3529 554
T 3629 554
T 3649 554
Drawing
Fig. C 091B-18a
No. of Part Number solder termination
cont. silver plating
Locking outside | straight
3
4
5
5S
2)
6
7
7
2)
8
12
14
3
4
5
5S
2)
6
7
7
2)
8
12
14
3
4
5
5S
2)
6
7
7
2)
8
12
14
T 3279 501
T 3329 501
T 3379 501
T 3399 501
T 3429 501
T 3439 501
T 3449 501
T 3529 501
T 3629 501
T 3649 501
T 3279 502
T 3329 502
T 3379 502
T 3399 502
T 3429 502
T 3439 502
T 3449 502
T 3529 502
T 3629 502
T 3649 502
T 3279 504
T 3329 504
T 3379 504
T 3399 504
T 3429 504
T 3439 504
T 3449 504
T 3529 504
T 3629 504
T 3649 504
T 3279 518
T 3329 518
T 3379 518
T 3399 518
T 3429 518
T 3439 518
T 3449 518
T 3529 518
T 3629 518
T 3649 518
T 3279 528
T 3329 528
T 3379 528
T 3399 528
T 3429 528
T 3439 528
T 3449 528
T 3529 528
T 3629 528
T 3649 528
T 3279 548
T 3329 548
T 3379 548
T 3399 548
T 3429 548
T 3439 548
T 3449 548
T 3529 548
T 3629 548
T 3649 548
gold plating
1)
Figure
(Please order crimp contacts separately, see page 56)
67,5
(2.658)
44,5
(1.752)
for cable diameter 4-6mm
Fig. C 091B-19a
62
(2.441)
53
(2.087)
PG 9
for cable diameter 6-8mm
Fig. C 091B-20a
62
(2.441)
53
(2.087)
PG 7
for cable diameter 4-6mm
28
1)
See remark page 25
2)
Contact arrangement acc. to DIN EN 61076-2-106 "0X-b"
20
(DIA.788)
20
(DIA.788)
20
(DIA.788)