Standard Frequencies – see Page 5 for developed frequencies.
* Check with factory for availability of frequencies not listed.
Applications
Automotive Electronics
Mobile Multimedia/Infotainment
Car Navigation Systems
Internet of Things [IoT, IIot]
Microcontrollers and FPGAs
Wireless Communication
Ethernet/GbE/SyncE
Medical Electronics
Commercial Military & Aerospace
Description
CTS Model SA324 incorporates a low cost, high Q, small size quartz resonator specifically developed to operate
over extended temperature ranges for use in automotive electronics.
Ordering Information
Model
SA324
Frequency Code
[MHz]
XXX or XXXX
Mode of
Oscillation
F
Tolerance
@ +25°C
3
Temperature
Stability
5
Temperature
Range
G
Load
Capacitance
A
Packaging
R
Code
Frequency
Product Frequency Code
1
Code
1
X
2
3
5
Tolerance
±10ppm
±15ppm
±20ppm
±30ppm
±50ppm
Code
I
G
H
N
P
M
Code
X
2
3
5
6
7
Stability
±15ppm
±20ppm
±30ppm
±50ppm
±100ppm
±150ppm
Temp. Range
-40°C to +85°C
2
-40°C to +105°C
3
-40°C to +125°C
4
-40°C to +150°C
5
-55°C to +105°C
5
-55°C to +125°C
5
Packing
Code
3k pcs./reel
R
Code
F
T
Mode
Fundamental
3rd Overtone
Code Capacitance Code Capacitance
7pF
16pF
V
C
8pF
18pF
K
D
9pF
20pF
J
E
10pF
24pF
A
F
12pF
30pF
L
G
13pF
Series
B
S
Notes:
1]
2]
3]
4]
5]
Refer to document 016-1454-0, Frequency Code Tables. 3-digits for frequencies <100MHz, 4-digits for frequencies 100MHz or greater.
Available with all stability codes.
Available with stability codes 3, 5, 6 and 7.
Available with stability codes 5, 6 and 7.
Stability codes 6 and 7. Contact factory for code 5 availability.
Not all performance combinations and frequencies may be available.
Contact your local CTS Representative or CTS Customer Service for availability.
This product is specified for use only in standard commercial applications. Supplier disclaims all express and implied warranties and liability in connection with any use of this
product in any non-commercial applications or in any application that may expose the product to conditions that are outside of the tolerances provided in its specification.
中国 北京—— Analog Devices, Inc. (纽约证券交易所代码 : ADI ),全球领先的高性能信号处理解决方案供应商,最新推出两款模拟输出驱动器—— AD5750 和 AD5751 ,能显著提高过程控制应用的效率和可靠性,包括那些在高恒流电压和高温条件下工作的过程控制应用。这两款器件基于 ADI 公司的 iCMOS ™工业工艺技术,输出驱动器的精度...[详细]
中风发生时,一切都是以秒来计算的。延误治疗可能导致大脑重大损伤。伦敦大学医学院的一位博士Alistair McEwan已经获得行为医学研究所(Action Medical Research)的同意,为急救人员开发一种无线诊断系统来减少时间延误。感谢抗血栓药物,一些病人在病情发作的三个小时之内可以完全恢复。但出血也会导致中风。医生在治疗之前需要确定发病原因,因为不适当的服用抗血栓药物会加重损害。...[详细]
目前医疗监护中无法动态掌握患者信息,一旦患者病情恶化,无法在第一时间实施抢救,对数据信息维护效率低。 文中首先阐述了蓝牙技术及其在医疗监护中应用的可行性,然后设计了系统框架,给出了具体功能,BlueTooth Wireless Communication Technology Application in Medical Monitoring包括数据采集和语音报警,最后对蓝牙信号在传输...[详细]