FEA121500G1S0N3J1A1A4A2A3Y1概述

Sensor/Transducer,

FEA121500G1S0N3J1A1A4A2A3Y1规格参数

参数名称属性值
Objectid145181546912
Reach Compliance Codeunknown
其他特性IP 67; IP68
主体高度80 mm
主体长度或直径100 mm
最高工作温度60 °C
最低工作温度-20 °C
封装主体材料ALUMINIUM
封装形状/形式CIRCULAR
传感器/温度传感器类型LIQUID FLOW SENSOR
最大供电电压230 V
最小供电电压100 V

FEA121500G1S0N3J1A1A4A2A3Y1文档预览

A B B ME A SUREME NT & ANA LY TICS | DATA SHE ET
AquaProbe FEA100
Insertion-type electromagnetic flow
sensor with WaterMaster transmitter
Measurement made easy
Maximum performance,
minimum hassle
Suitable for permanent or temporary installation
• total user flexibility
The most stable transmitter in the world
• self-calibrating transmitter and ultra-low temperature coefficient for
highest accuracy
One solution for all your needs
• designed for use in all clean water applications
Quick transmitter exchange
• revolutionary data storage enables transmitter interchange /
commissioning without reconfiguration
Advanced infrared service port
• supports simultaneous and parallel operation of HART, remote HMI,
cyclic data output and parameter dump
OIML R49 permanent self-checking
• type P approved transmitter
• continuous self-checking of flow sensor and transmitter ensures
highest accuracy / long term performance
3-Year material defect warranty (AquaProbe sensor)
'Hot tap' capability
• enables installation with no interruption to water supply
AQ UA P R OB E F EA 100
I N S ER T I ON F LOW S E NS O R W IT H WAT E RM A ST E R T R AN SMI T TE R | D S/F EA 100- EN RE V. B
3
AquaProbe FEA100
The AquaProbe FEA100 extends the capability of the ABB
AquaProbe flowmeter by bringing together the proven
AquaProbe flow sensor with the innovative WaterMaster
transmitter.
AquaProbe has been designed, in close consultation with the
water industry, as an economic alternative to full-bore
metering. It comprises an electromagnetic sensing head
mounted on the end of a support rod. The sensing head can
be installed in existing pipelines without the need for the
major excavations or alterations to pipework associated with
full-bore meters. It can be fitted without interrupting the
water supply and can be removed easily for periodic
calibration or inspection.
AquaProbe is designed for installation in existing pipelines by
means of a small valved tapping. It is normally installed with
the sensing head on the pipe centreline, but may be located
at the critical position (the mean velocity position) a distance
of 1/8 of the pipe diameter away from the wall.
It provides an accurate local measurement of the water
velocity and, provided the flow profile is developed fully, a
good flow volume measurement.
Figure 1
AquaProbe flow sensor
The high sensitivity of AquaProbe enables it to traverse the
pipe to establish the flow profile and so identify hydraulic
problems in complex systems or ensure maximum accuracy
from an AquaProbe that has been installed in a non-ideal
location.
If the profile is not fully developed, a traverse of the pipe can
be performed, enabling an accurate flow volume
measurement to be obtained in non-ideal networks.
Key features include the wide flow range with the minimum
measured velocity (well below that detected by insertion
turbine or DP devices), no moving parts resulting in increased
reliability and reduced maintenance.
AquaProbe is ideal for permanent installation to monitor
potable or clean water flow. Also through the provision of
multiple tappings on the supply pipelines, AquaProbe can be
used as a portable survey tool to assist in the building of an
accurate network model, locate leaks and check the operation
of installed full-bore meters.
Based on ABB-proven technology, AquaProbe is supported by
the expertise of ABB, the world’s leading flow meter
manufacturer with many pioneering advances in water flow
metering over the last decade – for example, AquaMag™,
WaterMaster™, AquaProbe™ and CalMaster™.
ABB operate nationally- and internationally-accredited flow
calibration facilities in the UK, Germany, USA, Australia, China
and India. We also offer comprehensive, locally based before-
and after-sales service.
4
AQ UA P RO B E F E A 10 0
I N S E R T I O N F LOW S E N S O R W I T H WAT E RMA STER T R A NS MIT TER | D S/F EA 100- EN REV. B
Comprehensive features
A wide range of features and user benefits are built into
WaterMaster as standard:
• bi-directional flow
• unique, self-calibrating transmitter (patent approval in
progress) for the ultimate in stability and repeatability
• OIML R49 Type P continuous self-checking transmitter,
with alarms, ensures both flow sensor and transmitter
accuracy
• true electrode and coil impedance measurement
• comprehensive simulation mode
• universal switch mode power supply (options are
available for AC and DC supplies)
• comprehensive self-diagnostics compliant with
NAMUR NE107
• programmable multiple alarm capability
• HART protocol over 4 to 20 mA and infrared link
• 3 configurable pulse / frequency and alarm outputs
• advanced infrared service port supports remote HMI,
HART, cyclic data out and parameter dump
• read-only switch and ultra-secure service password for
total security
• PROFIBUS DP v1 option
Menu
Easy Setup
Exit
Select
Figure 2
Comprehensive display
Figure 3 FEA100 remote system
AQ UA P R OB E F EA 100
I N S ER T I ON F LOW S E NS O R W IT H WAT E RM A ST E R T R AN SMI T TE R | D S/F EA 100- EN RE V. B
5
Support software
AquaProbe FEA100 also has on-board remote communication
ability, such as interfacing to PROFIBUS DP and HART, that
enables the user to collect data remotely.
ABB also supply ScrewDriver, an enhanced software that
provides users with all-round improved profile analysis, flow
profiling set-up, downloading and display options when used
in conjunction with a WaterMaster transmitter.
Improved performance through
Digital Signal Processing (DSP)
Advanced Digital Signal Processing (DSP) gives improved
performance and enables real-time measurements for
maximum reliability.
DSP enables the transmitter to separate the real signal from
the noise, providing high quality outputs especially in harsh
environments involving vibration, hydraulic noise and
temperature fluctuation.
Figure 4
PC software support
Intuitive navigation and configuration
The user-friendly interface enables fast and simple data entry
for all parameters. 'Easy Setup' guides the operator step-by-
step through the menu to set parameters as quickly as
possible, simplifying the commissioning phase.
大四了我的迷茫
五年大学快读完了,回首这几年自己到底学到了什么,为什么说我读了五年了,大专三年+本科两年=五年大学生涯,有时候想想我是怎么熬过来的,大专三年浑浑噩噩的混了过去,本科也快毕业了,虽然 ......
tangjianyuan 聊聊、笑笑、闹闹
AVR-HID:HID接口实现传感数据采集
因为系统自带HID驱动,所以省去了上位机驱动开发的环节,对于一些简单的设备,这是一个非常经典的实现方案。本文涉及的内容很多,从下位机HID设备端的开发,一直延伸到上位机应用软件的开发。 ......
cscl 测试/测量
CCSv5.4.0 Beta 1来啦!希望能够支持ubuntu下调试430LaunchPad
在http://e2e.ti.com/support/development_tools/code_composer_studio/f/81/t/251388.aspx一帖子中unfortunately the mps430 launchpad and eZ sticks are not yet supported under linux.Sorr ......
qinkaiabc 微控制器 MCU
TI 微控制器I8669/I44445(MCU)MSP430让低功耗与高性能兼得
通过检测门窗打开等事件,家庭安防传感器能够为居民们带来安全感。工业泵上的传感器发出的数据可以帮助工厂所有者及早检测到警示信号,从而防止出现故障并降低随着时间的推移而产生的维护成本。 ......
火辣西米秀 微控制器 MCU
后海初春雨雪诗配画
昨天晚上雨和雪今晨后海好风光春雨春雪喜煞人都说春雨贵如油春雪赛过白兰花大白天梦回唐朝对话唐代大文豪韩愈岑冲孟浩然春眠不觉晓很早处处闻啼鸟很闹夜来风雨声很轻花落知多少很少天街小雨润如 ......
jameswangsynnex 聊聊、笑笑、闹闹
CString 转换成char*问题
CString c_sTime("010904"); CString hour =c_sTime.Left(2); int num=atoi((char*)(LPCTSTR)hour); 转换后得到的num为0为什么;那一步出错了...
luyuanle 嵌入式系统

 
EEWorld订阅号

 
EEWorld服务号

 
汽车开发圈

 
机器人开发圈

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程 索引文件: 1815  232  1957  673  1507  37  5  40  14  31 

器件索引   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

北京市海淀区中关村大街18号B座15层1530室 电话:(010)82350740 邮编:100190

电子工程世界版权所有 京B2-20211791 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号 Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved