60-70MT..KPbF Series
Vishay High Power Products
Three Phase Bridge
(Power Modules), 60/70 A
FEATURES
• Package fully compatible with the industry
standard INT-A-PAK power modules series
• High thermal conductivity package, electrically
insulated case
RoHS
COMPLIANT
• Excellent power volume ratio, outline for easy connections
to power transistor and IGBT modules
• 4000 V
RMS
isolating voltage
• UL E78996 approved
• Totally lead (Pb)-free
MTK
• Designed and qualified for industrial level
DESCRIPTION
PRODUCT SUMMARY
I
O
60/70 A
A range of extremely compact, encapsulated three phase
bridge rectifiers offering efficient and reliable operation. They
are intended for use in general purpose and heavy duty
applications.
MAJOR RATINGS AND CHARACTERISTICS
SYMBOL
I
O
CHARACTERISTICS
60MT.K
60 (75)
T
C
50 Hz
60 Hz
50 Hz
60 Hz
85 (61)
420
440
870
790
8700
Range
Range
800 to 1600
- 40 to 150
70MT.K
70 (90)
85 (57)
480
500
1150
1050
11 500
UNITS
A
°C
A
I
FSM
I
2
t
I
2
√t
V
RRM
T
Stg
T
J
kA
2
s
kA
2
√s
V
°C
ELECTRICAL SPECIFICATIONS
VOLTAGE RATINGS
TYPE NUMBER
VOLTAGE
CODE
80
100
60-70MT..K
120
140
160
V
RRM
, MAXIMUM REPETITIVE
PEAK REVERSE VOLTAGE
V
800
1000
1200
1400
1600
V
RSM
, MAXIMUM NON-REPETITIVE
PEAK REVERSE VOLTAGE
V
900
1100
1300
1500
1700
10
I
RRM
MAXIMUM
AT T
J
MAXIMUM
mA
Document Number: 94356
Revision: 29-Apr-08
For technical questions, contact: ind-modules@vishay.com
www.vishay.com
1
60-70MT..KPbF Series
Vishay High Power Products
FORWARD CONDUCTION
PARAMETER
Maximum DC output
current at case temperature
Maximum peak, one-cycle
forward, non-repetitive
surge current
SYMBOL
I
O
TEST CONDITIONS
120° rect. conduction angle
t = 10 ms
I
FSM
t = 8.3 ms
t = 10 ms
t = 8.3 ms
t = 10 ms
Maximum I
2
t for fusing
I
2
t
t = 8.3 ms
t = 10 ms
t = 8.3 ms
Maximum I
2
√t
for fusing
Low level value of threshold voltage
High level value of threshold voltage
Low level value of forward slope resistance
High level value of forward
slope resistance
Maximum forward voltage drop
RMS isolation voltage
I
2
√t
V
F(TO)1
V
F(TO)2
r
f1
r
f2
V
FM
V
ISOL
No voltage
reapplied
100 % V
RRM
reapplied
No voltage
reapplied
100 % V
RRM
reapplied
Initial
T
J
= T
J
maximum
60MT.K
60 (75)
85 (61)
420
440
350
370
870
790
610
560
8700
0.85
1.07
8.04
7.08
1.75
4000
70MT.K
70 (90)
85 (57)
480
500
400
420
1150
1050
800
730
11 300
0.86
1.08
7.35
6.53
1.55
V
mΩ
A
2
√s
V
kA
2
s
A
UNITS
A
°C
Three Phase Bridge
(Power Modules), 60/70 A
t = 0.1 to 10 ms, no voltage reapplied
(16.7 % x
π
x I
F(AV)
< I <
π
× I
F(AV)
), T
J
maximum
(I >
π
x I
F(AV)
), T
J
maximum
(16.7 % x
π
x I
F(AV)
< I <
π
× I
F(AV)
), T
J
maximum
(I >
π
x I
F(AV)
), T
J
maximum
I
pk
= 100 A, T
J
= 25 °C, t
p
= 400 µs single junction
T
J
= 25 °C, all terminal shorted
f = 50 Hz, t = 1 s
THERMAL AND MECHANICAL SPECIFICATIONS
PARAMETER
Maximum junction operating and
storage temperature range
SYMBOL
T
J
, T
Stg
DC operation per module
Maximum thermal resistance,
junction to case
R
thJC
DC operation per junction
120° rect. conduction angle per module
120° rect. conduction angle per junction
Maximum thermal resistance,
case to heatsink per module
Mounting torque ± 10 %
Approximate weight
to heatsink
to terminal
R
thCS
Mounting surface smooth, flat and greased
A mounting compound is recommended and
the torque should be rechecked after a period
of 3 hours to allow for the spread of the
compound. Lubricated threads.
TEST CONDITIONS
60MT.K
70MT.K
UNITS
°C
- 40 to 150
0.37
2.22
0.40
2.42
0.03
4 to 6
3 to 4
176
0.29
1.75
0.34
2.01
K/W
Nm
g
www.vishay.com
2
For technical questions, contact: ind-modules@vishay.com
Document Number: 94356
Revision: 29-Apr-08
60-70MT..KPbF Series
Three Phase Bridge
(Power Modules), 60/70 A
60MT..K Series
140
Vishay High Power Products
130
120
110
100
90
80
70
60
50
Instantaneous Forward Current (A)
150
1000
Maximum Allowable Case
Temperature (°C)
120°
(Rect)
100
T
J
= 25 °C
T
J
= 150 °C
10
+
~
-
60MT..K Series
Per junction
1
0
10
20
30
40
50
60
70
80
0
1
2
3
4
5
Total Output Current (A)
Fig. 1 - Current Ratings Characteristics
Instantaneous Forward Voltage (V)
Fig. 2 - Forward Voltage Drop Characteristics
250
250
Maximum Total Power Loss (W)
225
200
175
150
125
100
75
50
25
0
60MT..K Series
T
J
= 150 °C
120°
(Rect)
Maximum Total Power Loss (W)
R
th
225
200
175
150
125
100
75
50
25
0
0.
0.3
0.5
SA
K/
W
0.
2
K/
K/
W
W
12
=
0.
05
8
W
K/
R
-
Δ
K/W
K/W
0.7
1 K/W
1.5 K
/W
0
10
20
30
40
50
60
70
80
0
25
50
75
100
125
150
Total Output Current (A)
Fig. 3 - Total Power Loss Characteristics
Maximum Allowable Ambient
Temperature (°C)
400
350
Peak Half Sine Wave
Forward Current (A)
Peak Half Sine Wave
Forward Current (A)
300
250
200
150
100
At any rated load condition and with
rated V
RRM
applied following surge.
Initial T
J
= 150 °C
at 60 Hz 0.0083 s
at 50 Hz 0.0100 s
450
400
350
300
250
200
150
100
50
Maximum non-repetitive surge current
versus pulse train duration.
Initial T
J
= 150 °C
No voltage reapplied
Rated V
RRM
reapplied
60MT..K Series
60MT..K Series
1
10
100
0.01
0.1
1.0
Number of Equal Amplitude
Half Cycle Current Pulses (N)
Fig. 4 - Maximum Non-Repetitve Surge Current
Pulse Train Duration (s)
Fig. 5 - Maximum Non-Repetitive Surge Current
Document Number: 94356
Revision: 29-Apr-08
For technical questions, contact: ind-modules@vishay.com
www.vishay.com
3
60-70MT..KPbF Series
Vishay High Power Products
150
140
Three Phase Bridge
(Power Modules), 60/70 A
Instantaneous Forward Current (A)
1000
70MT..K Series
Maximum Allowable Case
Temperature (°C)
130
120
110
100
90
80
70
60
50
120°
(Rect)
100
T
J
= 25 °C
10
+
~
-
T
J
= 150 °C
70MT..K Series
Per junction
0
20
40
60
80
100
1
0
1
2
3
4
5
Total Output Current (A)
Fig. 6 - Current Ratings Characteristics
Instantaneous Forward Voltage (V)
Fig. 7 - Forward Voltage Drop Characteristics
300
300
Maximum Total Power Loss (W)
250
200
150
100
50
0
70MT..K Series
T
J
= 150 °C
120°
(Rect)
Maximum Total Power Loss (W)
R
th
250
0.2
200
150
100
50
0
0.
1
SA
0.3
0.5
K/
K/
=
05
0.
W
W
W
K/
K/
W
R
-
Δ
K/W
0.7
K/W
1 K/W
1.5 K
/W
75
100
125
150
0
10
20
30
40
50
60
70
80
90
0
25
50
Total Output Current (A)
Maximum Allowable Ambient Temperature (°C)
Fig. 8 - Total Power Loss Characteristics
450
400
Peak Half Sine Wave
Forward Current (A)
Peak Half Sine Wave
Forward Current (A)
350
300
250
200
150
100
At any rated load condition and with
rated V
RRM
applied following surge.
Initial T
J
= 150 °C
at 60 Hz 0.0083 s
at 50 Hz 0.0100 s
500
450
400
350
300
250
200
150
100
Maximum non-repetitive surge current
versus pulse train duration.
Initial T
J
= 150 °C
No voltage reapplied
Rated V
RRM
reapplied
70MT..K Series
70MT..K Series
1
10
100
1
10
100
Number of Equal Amplitude
Half Cycle Current Pulses (N)
Fig. 9 - Maximum Non-Repetitive Surge Current
Pulse Train Duration (s)
Fig. 10 - Maximum Non-Repetitive Surge Current
www.vishay.com
4
For technical questions, contact: ind-modules@vishay.com
Document Number: 94356
Revision: 29-Apr-08
60-70MT..KPbF Series
Three Phase Bridge
(Power Modules), 60/70 A
Z
thJC
- Transient Thermal Impedance (K/W)
10
Steady state value
R
thJC
= 2.22 K/W
R
thJC
= 1.75 K/W
1
(DC operation)
70MT..K Series
60MT..K Series
Vishay High Power Products
0.1
Per junction
0.01
0.001
0.01
0.1
1
10
Square Wave Pulse Duration (s)
Fig. 11 - Thermal Impedance Z
thJC
Characteristics
ORDERING INFORMATION TABLE
Device code
7
1
1
2
3
4
5
-
-
-
-
-
0
2
MT
3
160
4
K
5
PbF
6
Current rating code: 6 = 60 A (average)
7 = 70 A (average)
Three phase diodes bridge
Essential part number
Voltage code x 10 = V
RRM
(see Voltage Ratings table)
PbF = Lead (Pb)-free
Note
• To order the optional hardware go to www.vishay.com/doc?95172
CIRCUIT CONFIGURATION
+
D
A
B
~
C
-
E
F
LINKS TO RELATED DOCUMENTS
Dimensions
http://www.vishay.com/doc?95004
Document Number: 94356
Revision: 29-Apr-08
For technical questions, contact: ind-modules@vishay.com
www.vishay.com
5