Assembly Instructions-C11
Type N
CRIMP-CRIMP TYPES
outer ferrule
Amphenol
Number
82-332
82-340
82-340-1052
82-340-1054
82-4425
82-4425-1003
82-4426
82-4426-1001
82-4426-1002
82-4427
82-4427-1006
82-4440
82-4440-1001
82-5370
82-5372
82-5373
82-5374
82-5375
82-5375-RFX
82-5378
82-5933
82-5988-1000
82-5988-1004
82-5993
82-5994
82-5995
82-6010
82-6106
82-5988-1000
82-5988-1004
Connector
Type
N Plug
N Plug
N Plug
N Plug
N Plug
N Plug
N Plug
N Plug
N Plug
N Plug
N Plug
N Angle Plug
N Angle Plug
N Plug
N Panel Jack
N Bulkh. Jack
N Angle Plug
N Plug
N Plug
N Bulkh. Jack
N Bulkh. Jack
N Angle Plug
N Angle Plug
N Plug
N Bulkh. Jack
N Angle Plug
N Plug
N Plug
N Angle Plug
N Angle Plug
Cable
RG-/U
9, 214
8, 213
B9913, 9914
LMR 400
9, 214, 225, 393
9, 214, 225, 393
8, 213
8, 213, 214 Eth.Cables
Ethernet Cables
Ethernet Cables
142, 400
142, 142B, 400
214, 225, 393
9, 214, 225, 393
55, 142, 223
55, 141, 142
55, 142, 223
55, 142, 223
58, 141
58, 141
58, 141
316
214, 393
214, 393
LMR 600
LMR 600
LMR 600
LMR 240
LMR 240
LMR 240
LMR 240
contact
Amphenol
®
body assembly
Hex Crimp Data
Cavity for
Die Set for
Outer Ferrule Tool 227-944‡
.429(10.9)
.429(10.9)
.429(10.9)
.429(10.9)
.429(10.9)
.429(10.9)
.429(10.9)
.429(10.9)
.429(10.9)
.429(10.9)
.213(5.4)
.213(5.4)
.429(10.9)
.429(10.9)
.213(5.4)
.213(5.4)
.213(5.4)
.213(5.4)
.213(5.4)
.213(5.4)
.213(5.4)
.178(4.5)
.429(10.9)
.429(10.9)
.612(15.5)
.612(15.5)
.612(15.5)
.255(6.5)
.255(6.5)
.255(6.5)
.255(6.5)
227-1221-25
227-1221-25
227-1221-63
227-1221-63
227-1221-25
227-1221-25
227-1221-25
227-1221-25
227-1221-25
227-1221-25
227-1221-57
227-1221-57
227-1221-25
227-1221-25
227-1221-57
227-1221-57
227-1221-57
227-1221-57
227-1221-57
227-1221-57
227-1221-57
227-1221-09
Strip Dimensions, inches (mm)
a
.531(13.5)
.531(13.5)
.539(13.7)
.539(13.7)
.687(17.4)
.687(17.4)
.687(17.4)
.630(16.0)
.687(17.4)
.687(17.4)
.687(17.4)
.600(15.2)
.687(17.4)
.687(17.4)
.600(15.2)
.600(15.2)
.640(16.3)
.687(17.4)
.531(13.5)
.630(16.0)
.640(16.3)
.502(12.7)
.827(21.0)
.827(21.0)
.844(21.4)
.844(21.4)
1.062(27.0)
.610(15.5)
.687(17.4)
.827(21.0)
.827(21.0)
b
.234(6.0)
.234(6.0)
.250(6.4)
.250(6.4)
.281(7.1)
.281(7.1)
.281(7.1)
.303(7.7)
.281(7.1)
.281(7.1)
.281(7.1)
.275(7.0)
.281(7.1)
.281(7.1)
.275(7.0)
.275(7.0)
.315(8.0)
.281(7.1)
.233(5.9)
.303(7.7)
.273(6.8)
.102(2.6)
.492(12.5)
.492(12.5)
.344(8.7)
.344(8.7)
.562(14.3)
.200(5.1)
.312(7.9)
.492(12.5)
.492(12.5)
c
.140(3.5)
.141(3.6)
.158(4.0)
.157(4.0)
.187(4.7)
.187(4.7)
.187(4.7)
.157(4.0)
.187(4.7)
.187(4.7)
.187(4.7)
.140(3.5)
.187(4.7)
.187(4.7)
.140(3.5)
.140(3.5)
.180(4.6)
.187(4.7)
.140(3.5)
.157(4.0)
.180(4.6)
.062(1.6)
.157(4.0)
.157(4.0)
.250(6.4)
.250(6.4)
.312(7.9)
.200(5.1)
.187(4.7)
.157(4.0)
.157(4.0)
Cavity for
Contact
.100(2.5)
.100(2.5)
.116(2.9)
.116(2.9)
.100(2.5)
.100(2.5)
.100(2.5)
.100(2.5)
.100(2.5)
.100(2.5)
.100(2.5)
.100(2.5)
.100(2.5)
.100(2.5)
.100(2.5)
.100(2.5)
.100(2.5)
.100(2.5)
.100(2.5)
.100(2.5)
.100(2.5)
Solder
Solder
Solder
.176(4.5)
.176(4.5)
Solder
Press-Fit
.100(2.5)
.100(2.5)
.100(2.5)
CTL Series
Tool No.
CTL-3
CTL-3
CTL-11
CTL-11
CTL-3
CTL-3
CTL-3
CTL-3
CTL-3
CTL-3
CTL-3
82-4426-11RFX
N Plug
Assembly
CTL-3
CTL-3
CTL-3
CTL-3
CTL-3
CTL-3
CTL-3
CTL-3
CTL-3
CTL-3
CTL-2
227-1221-6001 CTL-3
227-1221-6001 CTL-3
227-1221-6001 —
227-1221-6001 —
227-1221-6001 —
227-1221-59,-13 CTL-1.5,8
227-1221-59
227-1221-59
227-1221-59
CTL-5
CTL-5
CTL-5
Step 1
STEP 1
a
A
B
b
C
c
Step 1
Strip cable jacket, braid, and dielectric to dimensions shown. All cuts
are to be sharp and square.
Important:
Do not nick braid, dielectric,
and center conductor. Tinning of center conductor is not necessary if
contact is to be crimped. For solder method, tin center conductor
avoiding excessive heat.
Step 2
Slide outer ferrule onto cable as shown. Flare slightly end
of cable braid as shown to facilitate insertion of inner
ferrule.
Important:
Do not comb out braid.
Place contact on cable center conductor so it butts against
cable dielectric. Center conductor should be visible
through inspection hole in contact. Crimp or solder contact
in place as follows:
Crimp Method:
Use Die Set Cavity for contact indicated in
table above.Solder
Method:
Soft solder contact to cable center
conductor. Do not get any solder on outside surface of
contact. Avoid excessive heat to prevent swelling of dielectric.
Step 3
Install cable assembly into body assembly so inner ferrule
portion slides under braid. Push cable assembly forward
until contact snaps into place in insulator. Slide outer ferrule over braid
and up against connector body. Crimp outer ferrule using Die Set
Cavity specified in table above.
Step 2
STEP 2
crimp here
Step 3
STEP 3
crimp here
Amphenol Corporation Tel: 800-627-7100
www.amphenolrf.com
283