MHD2465N10A3V12

产品描述Absolute Magnetostrictive Sensor, 0.50-4.50V
产品类别传感器   
文件大小1MB,共4页
制造商MTS Sensors
官网地址https://www.mtssensors.com
下载文档 详细参数 全文预览

MHD2465N10A3V12概述

Absolute Magnetostrictive Sensor, 0.50-4.50V

MHD2465N10A3V12规格参数

参数名称属性值
Objectid1080341696
Reach Compliance Codeunknown
其他特性IP 67
外壳STAINLESS STEEL
线性度 (%)0.04 %
最高工作温度105 °C
最低工作温度-40 °C
输出范围0.50-4.50V
输出类型ANALOG VOLTAGE
分辨率100 µm
传感器/温度传感器类型LINEAR POSITION SENSOR,MAGNETOSTRICTIVE,ABSOLUTE
最大供电电压32 V
最小供电电压10 V
端接类型PIGTAIL

文档预览

下载PDF文档
Magnetostrictive Linear-Position Sensors
M-Series Mobile Equipment Sensor
Model MH
Analog Output
Temposonics
®
®
SENS
O
RS
550824 I
Product Specification
Cable Exit
Wire Exit
M-Series (Model MH)
sensor connection options
M-Series (Model MH) with analog output
(sensor cylinder application example)
Features
„
„
„
„
„
„
„
„
„
„
„
Linear, Absolute Position Sensors
Non-contact Sensor Technology
Superior Accuracy: Linearity < +/- 0.04% F.S.
Repeatability: < ± 0.005% F.S.
Compact Design for Embedded Cylinder Applications
No External Electronics
Analog Output: 0.25 - 4.75 Vdc, 4-20 mA
Sensor Stroke Length: 50 mm (1.97 in.) - 2500 mm (98.43 in.)
Power Supply: 12/24 Vdc
Shock Rating: 100 g (single hit) / IEC 68-2-27
Vibration Rating: 25 g / 10-2000 Hz / IEC 68-2-6
Benefits of magnetostrictive sensing
Temposonics linear-position sensors use the time based
magnetostrictive position sensing principle developed by MTS. Within
the sensing element, a sonic strain pulse is induced in a specially
designed magnetostrictive waveguide by the momentary interaction
of two magnetic fields. One field comes from a movable permanent
magnet that passes along the outside of the sensor. The other field
comes from an “interrogation” current pulse applied along the wave-
guide. The resulting strain pulse travels at ultrasonic speed along the
waveguide and is detected at the head of the sensing element.
The position of the magnet is determined with high precision and
speed by accurately measuring the elapsed time between the applica-
tion of the interrogation pulse and the arrival of the resulting strain
pulse with a high-speed counter. Elapsed time is used to determine
the permanent magnet position which provides an absolute position
reading that never requires recalibration or re-homing after a power
loss. Non-contact sensing eliminates wear, and guarantees the best
durability and output repeatability.
Product overview
Today’s buyers are more concerned with greater productivity,
lower overall operating costs and cost of ownership. Temposonics
M-Series Mobile Equipment sensors help lower overall costs by
increasing safety and versatility, increasing reliability and reducing
service costs. Temposonics Mobile Equipment sensors are designed
specifically for position sensing applications in rugged environments
typically encountered by construction, agriculture and other off-
highway machinery. All Temposonics Mobile Equipment sensors
utilize magnetostrictive technology.
The M-Series, Model MH sensor with analog output, is one of the
latest compact stainless-steel position sensors specifically designed
for use in welded and tie-rod style cylinders, or any space limited cyl-
inder application. The M-Series Model MH sensor is an ideal choice
for a wide range of standard hydraulic cylinders with diameters of 50
mm (1.97 in.) or larger.
The extremely rugged model MH sensor consists of the following
main components:
1. The sensor head; A robust housing with built-in electronics.
2. The pressure-proof sensor pipe; The sensor pipe houses and
protects the internal sensing element.
3. The position magnet; The magnet is mounted on the piston, during
operation it travels along the stationary sensor tube. This sensor
system is “non-contact” by design.
All specifications are subject to change. Contact MTS for specifications and engineering
drawings that are critical to your application. Drawings contained in this document are
for reference only. Go to www.mtssensors.com for the latest support documentation.
三星公司的S3C4510b的学习
小弟现在正在学习S3C4510b,这款ARM7好像大家都用得比较少。资料好像也不怎么多。 小弟手头缺乏这方面的学习资料,希望研究过4510b的高手些,给小弟发点学习资料。如果有在上面移植了tcp/ip的 ......
jekeytang1 嵌入式系统
microchip要收购atmel了
今天看到消息,说爱特梅尔(Atmel)公司董事会已经接受微芯科技(Microchip Technology)主动出价的收购邀约,并计划终止先前由英商戴乐格半导体(Dialog Semiconductor)收购的协议。 ...
dcexpert 聊聊、笑笑、闹闹
InTouch中DA Servers下如何定义访问名?
在InTouch中使用InTouch中DA Servers定义问题连接外部设备,我该怎么样定义访问名啊?如果在添加访问名应用程序名中填写了DA Servers的程序名字话启动WindowViewer的时候每次都提示应用程序名中 ......
eeleader 工业自动化与控制
推荐几本单片机入门好书
请大家推荐几本入门好书啊!谢谢啦!《51单片机开发与应用技术详解》这本书怎样啊??...
残月孤舟 单片机
2009年你涨工资了吗?
国际电子电机工程师学会美国分会(IEEE-USA)宣布,该组织最近针对成员所做的一项在线调查结果显示,美国科技工程师的薪资水平出现了5%的成长幅度。 根据IEEE统计,在2008年税务年度,美国的电子 ......
凯哥 工作这点儿事
【MSP430 编译器使用经验】在启动代码中关闭看门狗
MSP430的看门狗默认是打开的,如果在程序开始不关闭程序执行到一定时间msp430就会自动复位一次,那样程序就无法正常执行。一般在成为正式产品,要保证其可靠性的情况下再开看门狗,所以在我们编 ......
海盗郭兆广 微控制器 MCU

 
EEWorld订阅号

 
EEWorld服务号

 
汽车开发圈

 
机器人开发圈

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程 索引文件: 1622  2330  536  1315  592  21  20  36  19  57 

器件索引   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

北京市海淀区中关村大街18号B座15层1530室 电话:(010)82350740 邮编:100190

电子工程世界版权所有 京B2-20211791 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号 Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved