1
2
3
4
D
Description
Body
Socket
Insulation
Support
Spacer
Material
Brass
BE CU
Teflon
Brass
Teflon
Finish
Gold
Gold
Teflon
Gold
Teflon
D
SIDE VIEW
SOCKET
0.2x2x2 GROOVE
PIN CHUCK
C
Ø0.197
(5.00)
Ø0.106
(2.7)
0.244
(6.20)
0.382
(9.70)
0.575
(14.60)
SPACER
SUPPORT
C
Ø0.037
(0.95)
B
B
RECOMMENDED CABLE STRIPPING DIMENSIONS
0.142
(3.60)
0.020
(0.50)
0.217
(5.50)
CONMCX011-R178 ASSEMBLY INSTRUCTIONS
RG-178 Cable
1.
2.
3.
4.
5.
6.
Title
A
Strip the cable to the recommended dimensions.
Solder the support onto the braid.
Place the spacer onto the center conductor.
Solder or crimp the socket onto the center conductor.
Insert the socket, center conductor, spacer, and support into the body
until the socket snaps in.
Crimp the tail of the body onto the support with a hex crimp tool.
CONNECTOR CITY
159 ORT LANE
MERLIN, OR 97532
PH (541)-471-6256
FAX (541)-471-6251
A
MCX FEMALE CABLE END CRIMP
FOR RG178/U and RG196/U CABLE
CONMCX011-R178
INCHES (mm)
Part No.
Revision:
1.1
Date:
7/23/2008
Dimensions:
Sheet 1 of 1
1
2
3
4