电子工程世界电子工程世界电子工程世界

关键词

搜索

型号

搜索

FEA121500G1S0N1K1A1A6A2A4Y0

产品描述Sensor/Transducer,
产品类别传感器   
文件大小9MB,共16页
制造商ABB
官网地址http://www.abb.com/
下载文档 详细参数 全文预览

FEA121500G1S0N1K1A1A6A2A4Y0概述

Sensor/Transducer,

FEA121500G1S0N1K1A1A6A2A4Y0规格参数

参数名称属性值
Objectid145181555575
Reach Compliance Codeunknown
其他特性IP 67; IP68
主体高度80 mm
主体长度或直径100 mm
最高工作温度60 °C
最低工作温度-20 °C
封装主体材料ALUMINIUM
封装形状/形式CIRCULAR
传感器/温度传感器类型LIQUID FLOW SENSOR
最大供电电压26.4 V
最小供电电压16.8 V

FEA121500G1S0N1K1A1A6A2A4Y0文档预览

A B B ME A SUREME NT & ANA LY TICS | DATA SHE ET
AquaProbe FEA100
Insertion-type electromagnetic flow
sensor with WaterMaster transmitter
Measurement made easy
Maximum performance,
minimum hassle
Suitable for permanent or temporary installation
• total user flexibility
The most stable transmitter in the world
• self-calibrating transmitter and ultra-low temperature coefficient for
highest accuracy
One solution for all your needs
• designed for use in all clean water applications
Quick transmitter exchange
• revolutionary data storage enables transmitter interchange /
commissioning without reconfiguration
Advanced infrared service port
• supports simultaneous and parallel operation of HART, remote HMI,
cyclic data output and parameter dump
OIML R49 permanent self-checking
• type P approved transmitter
• continuous self-checking of flow sensor and transmitter ensures
highest accuracy / long term performance
3-Year material defect warranty (AquaProbe sensor)
'Hot tap' capability
• enables installation with no interruption to water supply
AQ UA P R OB E F EA 100
I N S ER T I ON F LOW S E NS O R W IT H WAT E RM A ST E R T R AN SMI T TE R | D S/F EA 100- EN RE V. B
3
AquaProbe FEA100
The AquaProbe FEA100 extends the capability of the ABB
AquaProbe flowmeter by bringing together the proven
AquaProbe flow sensor with the innovative WaterMaster
transmitter.
AquaProbe has been designed, in close consultation with the
water industry, as an economic alternative to full-bore
metering. It comprises an electromagnetic sensing head
mounted on the end of a support rod. The sensing head can
be installed in existing pipelines without the need for the
major excavations or alterations to pipework associated with
full-bore meters. It can be fitted without interrupting the
water supply and can be removed easily for periodic
calibration or inspection.
AquaProbe is designed for installation in existing pipelines by
means of a small valved tapping. It is normally installed with
the sensing head on the pipe centreline, but may be located
at the critical position (the mean velocity position) a distance
of 1/8 of the pipe diameter away from the wall.
It provides an accurate local measurement of the water
velocity and, provided the flow profile is developed fully, a
good flow volume measurement.
Figure 1
AquaProbe flow sensor
The high sensitivity of AquaProbe enables it to traverse the
pipe to establish the flow profile and so identify hydraulic
problems in complex systems or ensure maximum accuracy
from an AquaProbe that has been installed in a non-ideal
location.
If the profile is not fully developed, a traverse of the pipe can
be performed, enabling an accurate flow volume
measurement to be obtained in non-ideal networks.
Key features include the wide flow range with the minimum
measured velocity (well below that detected by insertion
turbine or DP devices), no moving parts resulting in increased
reliability and reduced maintenance.
AquaProbe is ideal for permanent installation to monitor
potable or clean water flow. Also through the provision of
multiple tappings on the supply pipelines, AquaProbe can be
used as a portable survey tool to assist in the building of an
accurate network model, locate leaks and check the operation
of installed full-bore meters.
Based on ABB-proven technology, AquaProbe is supported by
the expertise of ABB, the world’s leading flow meter
manufacturer with many pioneering advances in water flow
metering over the last decade – for example, AquaMag™,
WaterMaster™, AquaProbe™ and CalMaster™.
ABB operate nationally- and internationally-accredited flow
calibration facilities in the UK, Germany, USA, Australia, China
and India. We also offer comprehensive, locally based before-
and after-sales service.
4
AQ UA P RO B E F E A 10 0
I N S E R T I O N F LOW S E N S O R W I T H WAT E RMA STER T R A NS MIT TER | D S/F EA 100- EN REV. B
Comprehensive features
A wide range of features and user benefits are built into
WaterMaster as standard:
• bi-directional flow
• unique, self-calibrating transmitter (patent approval in
progress) for the ultimate in stability and repeatability
• OIML R49 Type P continuous self-checking transmitter,
with alarms, ensures both flow sensor and transmitter
accuracy
• true electrode and coil impedance measurement
• comprehensive simulation mode
• universal switch mode power supply (options are
available for AC and DC supplies)
• comprehensive self-diagnostics compliant with
NAMUR NE107
• programmable multiple alarm capability
• HART protocol over 4 to 20 mA and infrared link
• 3 configurable pulse / frequency and alarm outputs
• advanced infrared service port supports remote HMI,
HART, cyclic data out and parameter dump
• read-only switch and ultra-secure service password for
total security
• PROFIBUS DP v1 option
Menu
Easy Setup
Exit
Select
Figure 2
Comprehensive display
Figure 3 FEA100 remote system
AQ UA P R OB E F EA 100
I N S ER T I ON F LOW S E NS O R W IT H WAT E RM A ST E R T R AN SMI T TE R | D S/F EA 100- EN RE V. B
5
Support software
AquaProbe FEA100 also has on-board remote communication
ability, such as interfacing to PROFIBUS DP and HART, that
enables the user to collect data remotely.
ABB also supply ScrewDriver, an enhanced software that
provides users with all-round improved profile analysis, flow
profiling set-up, downloading and display options when used
in conjunction with a WaterMaster transmitter.
Improved performance through
Digital Signal Processing (DSP)
Advanced Digital Signal Processing (DSP) gives improved
performance and enables real-time measurements for
maximum reliability.
DSP enables the transmitter to separate the real signal from
the noise, providing high quality outputs especially in harsh
environments involving vibration, hydraulic noise and
temperature fluctuation.
Figure 4
PC software support
Intuitive navigation and configuration
The user-friendly interface enables fast and simple data entry
for all parameters. 'Easy Setup' guides the operator step-by-
step through the menu to set parameters as quickly as
possible, simplifying the commissioning phase.
有人用过江苏宏运的JMT1808R吗?
有人用过江苏宏运的JMT1808R吗?我目前正用它做一个案子,目前正在写底层函数,因是第一次使用该MCU,希望能交流心得。 ...
billliu66 51单片机
示波器的操作知识
很全面的示波器操作基础知识。是一份不错的资料。 14046 本帖最后由 emily 于 2009-1-12 15:16 编辑 ]...
emily 测试/测量
通过J2ME的录音功能实现简易示波器
本文来自http://blog.csdn.net/hellogv/ ,引用必须注明出处! 早就有人通过PC声卡的输入(麦克风孔)来做模拟示波器,但是用手机来实现的比较少。用J2ME的MMAPI实现模拟示波器,具体效 ......
soso DIY/开源硬件专区
请教!rtx
rtx在固件库程序包(v2.0)中的工程中使用,是否和mdk中rtx例子一样?...
jakysong stm32/stm8
新手MSP430求助
我刚接手430 ,可是弄了两天都没有把一个程序下载进板子,不知道是软件问题还是硬件问题。求一位大师指教啊!!...
1559355519 微控制器 MCU
有关ntfs文件系统的读写机制
大家好,请问ntfs文件系统读写文件的具体过程怎么样的?包括对$bitmap的修改,何时修改等,谢谢~是不是ntfs自己管理空闲空间的?假如下层的磁盘驱动程序返回的写入空间比ntfs要求写入的要少, ......
se7enmoon 嵌入式系统

 
EEWorld订阅号

 
EEWorld服务号

 
汽车开发圈

 
机器人开发圈

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程 索引文件: 1937  2043  2391  2528  2489  39  42  49  51  59 

器件索引   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

北京市海淀区中关村大街18号B座15层1530室 电话:(010)82350740 邮编:100190

电子工程世界版权所有 京B2-20211791 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号 Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved