Note: To protect the converter under all fault conditions, an input fuse is required. Quick-blow fuses
should be rated at 2x-3x the normal input current, time-delay fuses at 1.5x the normal input current.
Notes
Note 1:
Note 2:
Maximum capacitive load is defined as the capacitive load that will allow start up in under 1 second without damage to the converter
The RS3 series requires a minimum of 10% load on the output to maintain specified regulation. Operating under no-load conditions
will not damage these devices; however, they may not meet all listed specifications.
E-134
REV: 0/2014
www.recom-power.com
ECONOLINE
DC/DC-Converter
Typical Characteristics
RS3-S_D/(Z)
Series
RS3-4805D
Efficiency / Load
100
80
60
40
RS3-0505S
Efficiency / Load
100
80
60
40
Efficiency %
Efficiency %
20
0
20
0
0% 20%
40%
60%
Total Output current (%)
80%
100%
0% 20%
40%
60%
Total Output current (%)
80%
100%
Package Style and Pinning (mm)
9.20
11.10
4.1 typ.
Single Output
Dual Output
RECOM
RS3-xxxx
****
0.50±0.05
RECOM
RS3-xxxxS(Z)
****
1 2 3
5 6 7 8
RECOM
RS3-xxxxD(Z)
****
1 2 3
5 6 7 8
0.50±0.05
Recommended Footprint Details
21.80
0.32
Bottom View
Pin Connections
Pin #
1
2
3
2.54
1.0ø+0.15/0
Single
–Vin
+Vin
CTRL
NC
+Vout
–Vout
NC
Dual
–Vin
+Vin
CTRL
NC
+Vout
Com
–Vout
3.20
2.0
2.54
Top View
5
6
7
XX.X ± 0.5 mm
XX.XX ± 0.25 mm
8
RS3
NC = No Connection
Pin 8 (NC*)
This pin is used internally and must have no external connection.
Pin 5 (NC)
Not connected internally.
Pin 3 (CTRL)
This pin provides an Off function which puts the converter into a low power mode. When the pin is ‘high’ the converter is OFF and when the pin is high ‘Z’ the converter is ON.
There is no allowed low state for this pin.
Application Examples
ON/OFF CONTROL
V+
V
IN
+
ON
OFF
V
IN
-
LEAVE OPEN
CTRL
+Vin
+Vout
3
5~12
-Vin
1N4148
68
CTRL
Ω
-Vout
10K
FET.
V-
I
= 3V
O = 0.5V or GND
Remote ON/OFF
ON: open or high impendance
OFF: external 5~12 Vdc and 1N4148+ 68Ω resistor