Information Technology Equipment, General Requirements for Safety
EAC
RoHs 2+
www.recom-power.com
REV.: 1/2018
Report / File Number
1602031
RU-AT.49.09571
Standard
IEC60950-1:2005, 2nd Edition + A2:2013
EN60950-1:2006 + A2:2013
TP TC 004/2011
RoHS-2011/65/EU + AM-2015/863
ECO-3
RU/RUM
DC/DC Converter
Specifications
(measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
DIMENSION AND PHYSICAL CHARACTERISTICS
Parameter
Material
Package Dimension (LxWxH)
Package Weight
Series
Type
case
potting
PCB
RU
RUM
Value
non-conductive black plastic (UL94 V-1)
epoxy, (UL94 V-0)
FR4, (UL94 V-1)
19.65 x 7.0 x 10.2mm
16.55 x 6.0 x 7.7mm
2.7g typ.
Dimension Drawing (mm)
RU
SIP7 Package
Pinning information
embossed logo
19.6
6.0
Marking
Pin #
1
2
4
5
6
7
0.25
Single
+Vin
-Vin
+Vout 1
-Vout 1
+Vout 2
-Vout 2
0.51
10.2
4.10
0.51
+0.10/-0.05
Tolerance:
xx.x= ±0.5mm
xx.xx= ±0.25mm
Recommended Footprint Details
1.27
1 2
2.0
Bottom View
2.54
4 5 6 7
1 2
2.54
Top View
4 5 6 7
6x2.54= 15.24
RUM
SIP6 Package
embossed logo
7.7
16.55
6.0
Pinning information
Pin #
1
2
3
4
5
6
Tolerance:
xx.x= ±0.5mm
xx.xx= ±0.25mm
0.51
Marking
4.10
0.51
+0.10/-0.05
0.25
±0.05
Single
+Vin
-Vin
+Vout 1
-Vout 1
+Vout 2
-Vout 2
Recommended Footprint Details
1.27
Bottom View
2.54
1 2 3 4 5 6
1.9
5x2.54 = 12.70
1 2 3 4 5 6
Top View
2.54
www.recom-power.com
REV.: 1/2018
ECO-4
RU/RUM
DC/DC Converter
Specifications
(measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
INSTALLATION AND APPLICATION
Typical Application
fuse
Channel 1
Series
Channel 2
PACKAGING INFORMATION
Parameter
Packaging Dimension (LxWxH)
Packaging Quantity
Storage Temperature Range
Storage Humidity
tube
Type
tube
RU
RUM
Value
520.0 x 16.0 x 9.0mm
25pcs
30pcs
-55°C to + 125°C
95% RH max.
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The
products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized
use of RECOM products in such safety-critical applications.