Tripp Lite's OMNI650LCD Line-Interactive Digital UPS System offers voltage regulation, surge suppression and long-lasting battery support for personal
computers, home entertainment systems and media centers. Internal UPS circuits support entry-level PCs for up to 40 min. or individual VCR/DVR
components for as long as 2 hours during power failures. Prevents data loss, viewing interruptions, lost recordings and loss of component programming.
Automatic Voltage Regulation (AVR) circuits regulate brownouts as low as 89v back to usable levels without consuming battery power. Offers complete power
protection in an attractive black tower configuration. Includes 4 battery-supported/surge-protected outlets, plus 4 additional surge suppression-only outlets for
items not requiring battery support. USB port enables optional unattended system shutdown without data loss in case of extended power failure. PowerAlert
Software available via free download from www.tripplite.com. HID-compliant USB interface enables integration with built-in power management and auto
shutdown features of Windows and Mac OS X. Built-in audible alarm and large LCD front panel voltage display indicates line power status, battery power
status, battery low/replace status and voltage boost operation. The LCD display includes a dimmer switch and can be rotated for easy viewing in any
application. 650VA/350W power handling ability supports entry-level PCs, home entertainment systems, network workstations, audio/video components. Offers
4.4 min. battery runtime with a full load of 650VA/350W and 13.8 min. with a half load of 325VA/175W. Supports user battery replacement via built-in access
panel. $200,000 Ultimate Lifetime Insurance (USA and Canada Only).
Features
LCD Display indicates input voltage, battery capacity and a variety of operating conditions. LCD Display includes a dimmer switch and is rotatable for
easy viewing with UPS in either vertical or horizontal position.
OMNI650LCD Digital Uninterruptible Power Supply offers voltage regulation, surge suppression and long-lasting battery support during blackouts
Supports entry-level PCs up to 40 min. or single VCR/DVR components for up to 2 hours during blackouts
Regulates brownouts as low as 89V back to usable levels without consuming battery power
4 UPS battery-supported/surge-protected outlets plus 4 additional surge suppression-only outlets
USB port and PowerAlert software enables unattended shutdown in case of extended power failure
HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X.
PowerAlert Software available via free download from www.tripplite.com
650VA/350W power handling ability supports a variety of sensitive computer, home theater and other equipment
4.4 min. full load runtime (650VA/350W), 13.8 min. half-load runtime (325VA/175W)
Cabinet adapts to tower format or rackmount shelf format. Rackmount (2U)
1
format requires an optional shelf, available separately
/5
Cabinet adapts to tower format or rackmount shelf format. Rackmount (2U) format requires an optional shelf, available separately
Supports battery replacement via built-in access panel
Optional PDUB15 bypass PDU enables hot-swappable UPS replacement with no disruption to connected equipment
$200,000 Ultimate Lifetime Insurance (USA and Canada Only)
Specifications
OUTPUT
Output Volt Amp Capacity (VA)
Output Watt Capacity (watts)
Nominal Output Voltage(s)
Supported
Frequency compatibility
Output voltage regulation (Battery
mode)
Built-in UPS output receptacles
Surge suppression only outlets
Hot-Swap PDU options
Output AC waveform (AC mode)
Output AC waveform (battery mode)
650
350
115V; 120V
60 Hz
115V (+/- 5%)
8 5-15R outlet(s)
4 UPS outlets, 4 surge-only outlets
PDUB15 (2U / 8 5-15R outlets)
Sine wave
PWM sine wave
INPUT
Rated input current (at maximum
load)
Nominal Input Voltage(s) Supported
UPS input connection type
UPS Input cord length (ft.)
UPS Input cord length (m)
Recommended Electrical Service
Phase
12A
120V AC
5-15P
6
1.8
15A 120V
Single-Phase
BATTERY
Full load runtime (minutes)
Half load runtime (minutes)
DC system voltage (VDC)
Battery recharge rate (included
batteries)
Replacement battery cartridge
(internal UPS battery replacement)
4.4 min. (350w)
13.8 min. (175w)
12
Less than 20 hours from 10 to 90%
RBC51
2/5
Battery Access
Battery replacement description
Battery access door
Hot-swappable, user replaceable batteries
VOLTAGE REGULATION
Voltage regulation description
Undervoltage correction
Automatic voltage regulation (AVR) maintains line power operation with input voltage as low as 89
Input voltages between 89 and 104 are boosted by 14%
LEDS ALARMS & SWITCHES
LED Indicators
Front panel LCD display
Alarms
Alarm cancel operation
Switches
Front panel LCD display
Backlighted LCD screen indicates input voltage, 5-bar battery charge level, overload, AVR, on battery and replace
battery status; LCD screen rotates for rack/tower viewing
Audible alarm indicates power-failure, low-battery and overload status; alarm can be disabled using PowerAlert
software
Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate
low-battery status
2 Switches control off/on power status and alarm-cancel/self-test operation; dimmer switch controls LCD brightness
SURGE / NOISE SUPPRESSION
UPS AC suppression joule rating
UPS AC suppression response time
480
Instantaneous
PHYSICAL
Installation form factors supported
with included accessories
Primary form factor
UPS / Power Module dimensions in
primary form factor (height x width x
depth / inches)
UPS / Power Module dimensions in
primary form factor (height x width x
depth / cm)
Installed whole system dimensions
in secondary form factor (height x
width x depth / cm)
Secondary form factor
Installed whole system dimensions
in secondary form factor (height x
width x depth / inches)
UPS dimensions in secondary form
factor (height x width x depth / cm)
UPS / Power Module weight (lbs)
UPS / Power Module weight (kg)
Tower
Tower
12 x 3.7 x 7.2
30.5 x 9.4 x 18.3
9.4 x 30.5 x 18.3
Horizontal desktop placement
3.7 x 12 x 7.2
9.4 x 30.5 x 18.3
15.5
7
3/5
UPS Shipping dimensions (height x
width x depth / inches)
UPS Shipping dimensions (height x
width x depth / cm)
Shipping weight (lbs)
Shipping weight (kg)
Cooling method
UPS housing material
10.4 x 15.6 x 4.8
26.5 x 39.5 x 12.3
15.8
7.2
Convection
ABS
ENVIRONMENTAL
Operating Temperature Range
Storage Temperature Range
Relative Humidity
AC mode BTU / hr. (full load)
Battery mode BTU / hr. (full load)
AC mode efficiency rating (100%
load)
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
0 to 95%, non-condensing
36.8
396.7
97%
COMMUNICATIONS
Communications interface
PowerAlert software
Communications cable
WatchDog compatibility
USB (HID enabled)
Free download from www.tripplite.com
User supplies USB cable
Supports Watchdog application, OS and hard-reboot restart options for remote applications
LINE / BATTERY TRANSFER
Transfer time
Low voltage transfer to battery
power (setpoint)
High voltage transfer to battery
power (setpoint)
4 milliseconds
89
139
SPECIAL FEATURES
Cold Start (startup in battery mode
during a power failure)
Green & high efficiency features
Cold-start operation supported
Greater than 95% efficiency - GREEN UPS
CERTIFICATIONS
UPS Certifications
Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category B (EMI)
WARRANTY
4/5
Product Warranty Period (U.S. &
Canada)
Product Warranty Period (Latin
America)
Product Warranty Period
(International)
Product Warranty Period (Mexico)
Connected Equipment Insurance
(U.S., Canada & Puerto Rico)
3-year limited warranty
3-year limited warranty
2-year limited warranty
3-year limited warranty
$200,000
Ultimate Lifetime Insurance
Related Items
Optional Products
Model Number
DCATV
DNET1
DTEL2
SRSHELF2P
WATCHDOGSW
WEXT5-OMNI
PDUB15
Description
Network Surge Suppressor - Essential protection for TV/VCR coaxial lines
Network Surge Suppressor - Essential protection for data and communication lines
Network Surge Suppressor - Essential protection for data and communication lines
2U Cantilever Fixed Shelf (60 lb / 27 kg capacity; 18-in. / 457 mm depth.)
WatchDog Service Monitoring / Reboot Software
5-Year Extended Warranty - For OmniSmart, OmniPro, OmniVS
编译自semiengineering 业界越来越关注人工智能的功耗问题,但这个问题并没有简单的解决方案。这需要深入了解应用、半导体和系统层面的软件和硬件架构,以及所有这些的设计和实现方式。每个环节都会影响总功耗和提供的效用。这是最终必须做出的权衡。 但首先,必须解决效用问题。电力是否被浪费了?“我们将电力用于有价值的用途,”Ansys(现为新思科技旗下公司)产品营销总监 Marc Swi...[详细]