SmartPro .75kVA 600W Line Interactive Sine Wave
UPS, Extended-run & SNMPWEBCARD options, 2U
Rack/Tower, LCD, USB, RS232, EPO, 120V
MODEL NUMBER:
SMART750RMXL2U
Highlights
.75kVA / 750VA / 600W line
interactive 2U rack/tower UPS,
Sine wave output
120V output, Corrects brownouts
and overvoltages from 83V to
147V
0.8 Power Factor, Interactive
LCD interface
Extended runtime options up to
450W
4 post compatible mounting
accessories
95% line-mode efficiency, 2
switched load banks
USB, RS232, EPO and slot for
SNMPWEBCARD option
120V NEMA 5-15P input, 6
NEMA 5-15R outlets
Description
Tripp Lite SmartPro Line Interactive UPS with enhanced LCD interface offers network-grade power protection for
critical server, network and telecommunications equipment. Line Interactive Uninterruptible Power Supply (UPS)
with built-in Auto-Voltage Regulation (AVR) actively corrects brownouts and overvoltages back to usable levels
while maintaining a full battery charge in case of power failure. Interactive LCD interface reports UPS operating
mode, detailed UPS and site-power data, plus enables a variety of UPS setup and configuration options.
Super-fast switchover from line to battery power occurs within milliseconds to maintain operation of connected
equipment without interruption or reboot. 95% line-mode efficiency offers reduced heat emissions and operating
Package Includes
SMART750RMXL2U UPS
System
PowerAlert software with USB,
Serial & EPO cabling
4 post installation kit
Owner's manual
costs. Network management interfaces support communications via USB, RS-232 and optional SNMPWEBCARD network interface. HID-compliant USB
interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. Network communications ports enable
detailed monitoring of equipment load levels, self-test data and utility power conditions. Includes PowerAlert monitoring software and complete cabling.
Switched output load banks enable scheduled and real-time remote reboot and load shedding of select outlets. Emergency Power Off (EPO) interface. LCD
display panel easily rotates for viewing in rackmount or tower configurations. Audible alarm with push-button momentary alarm-cancel and silent-mode
configuration options. Programmable self-test. Field-replaceable, hot-swappable battery modules.
Features
Tripp Lite SMART750RMXL2U line interactive 2U rack/tower UPS with 750VA / .75kVA / 600W capacity and extended runtime options
Line interactive UPS with Automatic Voltage Regulation (AVR) corrects brownouts and overvoltages from 83 to 147V
NEMA 5-15P input plug; 6 NEMA 5-15R output receptacles, Two independently switched output load banks
Maintains uninterrupted operation of connected networking equipment during blackouts, surges, brownouts and overvoltages
High 95% efficiency rating in line-power mode offers reduced power consumption and BTU emisssions
Internal batteries offer 20.7minutes at 50% load (300W) and 8.5 minutes at 100% load (600W)
Extended runtime is available with optional BP24V15RT2U (limit 1), BP24V28-2U (limit 1), BP24V70-3U (multi-pack compatible) and BP24V36-2US
(multi-pack compatible); Output is reduced to 450 watts maximum with external battery packs
External battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual)
1/6
Hot-swappable, user-replaceable internal batteries and external battery packs can be replaced with no disruption to connected equipment
Front panel LCD monitoring screen with MODE and ENTER buttons reports operating mode with 5-bar battery charge graphic, plus 7 selectable screens
of detailed UPS and site power information
LCD interface also supports a number of advanced user setup and operating preferences
Ships with 4 post rackmount installation hardware; Optional 2POSTRMKITWM enables 2 post rackmount/wallmount installation; Optional 2-9USTAND
enables tower placement
Built-in USB, RS-232 and optional SNMPWEBCARD accessory monitoring options
HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X
Included PowerAlert UPS monitoring software; Built-in Emergency Power Off (EPO) interface with cable
Specifications
OUTPUT
Output Volt Amp Capacity (VA)
Output kVA capacity (kVA)
Output Watt Capacity (watts)
Output kW capacity
Output power factor
Output Capacity Details
Nominal Output Voltage(s)
Supported
Frequency compatibility
Output voltage regulation (line mode)
Output voltage regulation (Battery
mode)
Built-in UPS output receptacles
Built-in controllable switched load
banks
Output AC waveform (AC mode)
Output AC waveform (battery mode)
750
.75
600
.6
0.8
Output derates to 450 watts in all external battery pack configurations
120V
60 Hz
-21%, +8%
+/- 5%
6 5-15R outlet(s)
Two switchable two-outlet 5-15R load banks
Sine wave
Pure Sine wave
INPUT
Rated input current (at maximum
load)
Nominal Input Voltage(s) Supported
UPS input connection type
Input circuit breaker
UPS Input cord length (ft.)
UPS Input cord length (m)
7.5A
120V AC
5-15P
10A
10
3.05
2/6
Recommended Electrical Service
Phase
15A 120V
Single-Phase
BATTERY
Full load runtime (minutes)
Half load runtime (minutes)
Expandable battery runtime
External battery pack compatibility
DC system voltage (VDC)
Battery recharge rate (included
batteries)
Replacement battery cartridge
(internal UPS battery replacement)
Battery Access
Battery replacement description
8.5 min. (600w)
20.7 min. (300w)
Extended runtime supported via optional external battery packs
BP24V15RT2U
(limit 1);
BP24V28-2U
(limit 1);
BP24V70-3U
(multi-pack compatible);
BP24V36-2US
(multi-pack
compatible)
24
Less than 4.5 hours from 10% to 90%
See Tripp Lite UPS Replacement battery selector
Front panel battery access door
Hot-swappable, user replaceable batteries
VOLTAGE REGULATION
Voltage regulation description
Overvoltage correction
Undervoltage correction
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 147
Input voltages between 128 and 147 are reduced by 12%
Input voltages between 83 and 107 are boosted by 14%
LEDS ALARMS & SWITCHES
LED Indicators
Alarms
Alarm cancel operation
Switches
Front panel LCD information and configuration screen offers detailed UPS and site power status and operating
data, plus configuration of voltage, operating mode, alarm function and a variety of additional options (see manual
for detailed LCD configuration and monitoring options)
Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions
Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option
available
3 pushbutton switches control OFF / ON power status, MODE selection and MUTE / ENTER control functions
SURGE / NOISE SUPPRESSION
UPS AC suppression joule rating
EMI / RFI AC noise suppression
570 joules
Yes
PHYSICAL
Installation form factors supported
with optional accessories
Primary form factor
2 post rackmount (2POSTRMKITWM); Wallmount (2POSTRMKITWM); Tower (2-9USTAND)
Rackmount
3/6
UPS / Power Module dimensions in
primary form factor (height x width x
depth / inches)
UPS / Power Module dimensions in
primary form factor (height x width x
depth / cm)
Rack Height
Secondary form factor
UPS / Power Module weight (lbs)
UPS / Power Module weight (kg)
UPS Shipping dimensions (height x
width x depth / inches)
UPS Shipping dimensions (height x
width x depth / cm)
Shipping weight (lbs)
Shipping weight (kg)
Cooling method
UPS housing material
3.45 x 17.35 x 13.15
8.8 x 44.1 x 33.4
2U
Tower (requires
2-9USTAND)
35.4
16.1
7.9 x 22.85 x 19.3
20.1 x 58 x 49
46.4
21.1
Fan
Steel
ENVIRONMENTAL
Operating Temperature Range
Storage Temperature Range
Relative Humidity
AC mode BTU / hr. (full load)
AC mode efficiency rating (100%
load)
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
0 to 95%, non-condensing
109
95%
COMMUNICATIONS
Communications interface
Network monitoring port description
PowerAlert software
Communications cable
WatchDog compatibility
USB; DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface
Supports detailed monitoring of UPS and site power conditions
Included
USB and DB9 cabling included
Supports Watchdog application, OS and hard-reboot restart options for remote applications
LINE / BATTERY TRANSFER
Transfer time
Low voltage transfer to battery
power (setpoint)
High voltage transfer to battery
power (setpoint)
4 milliseconds (AC to battery mode), 2 milliseconds (Battery to AC mode)
83
147
4/6
SPECIAL FEATURES
Grounding lug
Cold Start (startup in battery mode
during a power failure)
High availability UPS features
Green & high efficiency features
Back panel grounding lug
Cold-start operation supported
Hot swappable batteries
Individually controllable load banks
CERTIFICATIONS
UPS Certifications
Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category B (EMI)
WARRANTY
Product Warranty Period (Worldwide)
Connected Equipment Insurance
(U.S., Canada & Puerto Rico)
2-year warranty, 3 year with registration. Note:
Registration is required
for 3-year warranty.
$250,000
Ultimate Lifetime Insurance
Related Items
Optional Products
Model Number
WEXT5-500-1500
SNMPWEBCARD
ENVIROSENSE
SRSWITCH
BP24V36-2US
BP24V15RT2U
BP24V28-2U
BP24V70-3U
2POSTRMKITWM
RBC24V-LCD
2-9USTAND
PDUB15
PDU1215
PDUV15
Description
5-Year Extended Warranty - For Smart Line-Interactive and Online Tower or Rack models, 1500VA
or less
For remote monitoring and control via SNMP, Web, or Telnet.
Monitors temperature, humidity and contact-closure inputs. (Requires SNMPWEBCARD or switched
PDU.)
Magnetic Door Switch Kit for front and rear doors; requires ENVIROSENSE
BP24V36-2US - 2U External 24V Rackmount Battery Pack for select Tripp Lite UPS Systems
BP24V15RT2U - External Battery Pack for UPS System
BP24V28-2U - External Battery Pack for UPS System
BP24V70-3U - External Battery Pack for UPS System
Enables 2-Post Rackmount or Wallmount Installation of Select Rackmount UPS Systems
2U UPS Replacement Battery Cartridge for select Tripp Lite UPS
Enables Tower Placement of Rackmount UPS Systems
Single-Phase Hot-Swap PDU, 15A 120V, 2U Horizontal Rackmount, 8 NEMA 5-15R outlets, set of 2
NEMA 5-15P input plugs
Basic PDU / Power Distribution Unit - Safe, reliable power distribution for critical networking
equipment
Single-Phase Basic PDU, 15A 120V, 0U Vertical Rackmount, 14 NEMA 5-15R outlets, NEMA 5-15P
input plug
5/6
Qty.
1
1
1
1
1
1
1
1
1
1
1
1
1
1